Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Social and Behavioral Sciences

2006

Turbine

Articles 1 - 3 of 3

Full-Text Articles in Engineering

Energy Storage System For Reduction Of Mid-Line Voltage Variation Of A Dfig Wnd Turbine Connected To A Weak Grid, M Aktarujjaman, Kashem M. Muttaqi, Michael Negnevitsky, Gerard Ledwich Jan 2006

Energy Storage System For Reduction Of Mid-Line Voltage Variation Of A Dfig Wnd Turbine Connected To A Weak Grid, M Aktarujjaman, Kashem M. Muttaqi, Michael Negnevitsky, Gerard Ledwich

Faculty of Engineering and Information Sciences - Papers: Part A

Penetration of wind power into electricity system is constantly increasing. Wind resources are usually distant from existing transmission lines. Wind farms are often connected to weak grids far from central generation stations. Maximum wind power extraction causes the more irregular and unpredicted power output of wind turbine, which has same nature as wind speed variation. The voltage in such long line is vulnerable with the consumption and generation imbalance. In a long line, the mid-line voltage is largely affected by the variation and the penetration of the wind fluctuating power. Fluctuating nature of wind power output and long transmission line …


Control Stabilisation Of An Islanded System With Dfig Wind Turbine, M Aktarujjaman, Kashem M. Muttaqi, Michael Negnevitsky, Gerard Ledwich Jan 2006

Control Stabilisation Of An Islanded System With Dfig Wind Turbine, M Aktarujjaman, Kashem M. Muttaqi, Michael Negnevitsky, Gerard Ledwich

Faculty of Engineering and Information Sciences - Papers: Part A

Distributed Generation (DG) is often used to export power to the utility system. Loss of main supply can cause a severe loading mismatch between DG generation and load consumption. Consequently, the voltage and frequency of the islanded system will cross the allowable limit. Due to this fact, it is essential to control the voltage and frequency in the islanding mode of operation. In this paper, control stabilisation of an islanded system with a doubly-fed induction generator (DFIG) wind turbine has been addressed. Wind DG produces variable output and is not capable to produce enough reactive power. Hence, it is imperative …


Hydro-Turbine Governor Control: Theory, Techniques And Limitations, J Culberg, Michael Negnevitsky, Kashem M. Muttaqi Jan 2006

Hydro-Turbine Governor Control: Theory, Techniques And Limitations, J Culberg, Michael Negnevitsky, Kashem M. Muttaqi

Faculty of Engineering and Information Sciences - Papers: Part A

With the entry of Tasmania into the national electricity market, equipment upgrades are required in many parts of the existing power system. This presents an opportunity to embrace new technology, in order to enhance the current efficiency and productivity of the system. One area is that of hydro-turbine speed governors, an integral part of maintaining the frequency of the output. This paper analyses the current standard control algorithm for turbine governors, the PID controller. It illustrates the processes involved, tuning and their limitations. Finally, alternative control systems are discussed.