Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Social and Behavioral Sciences

Selected Works

Dr Philip Ciufo

Selected Works

Assessment

Publication Year

Articles 1 - 3 of 3

Full-Text Articles in Engineering

Power Quality Emission Assessment Of Photovoltaic Inverters Based On Iec Technical Report 61000-3-15:2011, Devinda Perera, Philip Ciufo, Lasantha G. Meegahapola, Sarath Perera Apr 2015

Power Quality Emission Assessment Of Photovoltaic Inverters Based On Iec Technical Report 61000-3-15:2011, Devinda Perera, Philip Ciufo, Lasantha G. Meegahapola, Sarath Perera

Dr Philip Ciufo

The International Electrotechnical Committee Technical Report IEC 61000-3-15:2011 provides electromagnetic compatibility requirements and test conditions for distributed generators up to 75 A per phase. In the current research, two commercially available photovoltaic (PV) inverters up to the capacity of 3600 W were tested following the guidelines proposed in IEC 61000-3-15 in relation to low order harmonic emission and flicker emission. In addition, the harmonic and flicker emission behaviour of the PV inverters were investigated under varying irradiation conditions. Both PV inverters were observed to comply with the emission requirements prescribed by the technical report under most conditions except for even …


Voltage Unbalance Emission Assessment: Sources Of Contribution And Their Ranking, U Jayatunga, Sarath Perera, P Ciufo, A P. Agalgaonkar Apr 2015

Voltage Unbalance Emission Assessment: Sources Of Contribution And Their Ranking, U Jayatunga, Sarath Perera, P Ciufo, A P. Agalgaonkar

Dr Philip Ciufo

etermining sources of voltage unbalance (VU) and quantifying their individual contributions in an interconnected network is a complex task due to multiple interactions that take place between them. Post-connection VU emission assessment techniques in relation to customer installations are important not only in compliance assessment according to IEC/TR 61000-3- 13:2008 Limits - Assessment of emission limits for the connection of unbalanced installations to MV, HV and EHV power systems, but also in determining the various emission contributors in the power system being considered. This paper presents a case study on the application of a recently developed post-connection VU emission assessment …


Comparison Of Methodologies For Assessment Of Harmonic Current Emission Limits For Large Installations Connected To Lv Networks, Biyanvilage Perera, Sarath Perera, Philip Ciufo, Victor J. Gosbell Feb 2013

Comparison Of Methodologies For Assessment Of Harmonic Current Emission Limits For Large Installations Connected To Lv Networks, Biyanvilage Perera, Sarath Perera, Philip Ciufo, Victor J. Gosbell

Dr Philip Ciufo

With the proliferation of large, disturbing installations (loads and distribution generators) connected to public low voltage networks, managing the harmonic voltage levels in the network has become a key concern to distribution network service providers (DNSPs). Therefore, it is important that DNSPs limit the harmonic current emission by individual installations. This paper reviews a number of methodologies that exist in the current technical literature in relation to the assessment of harmonic current emission limits for disturbing installations connected to the public LV network. Application of these methodologies is demonstrated through a case study on a test network. The study shows …