Improved Workflow Modelling Using Role Activity Diagram-Based Modelling With Application To A Radiology Service Case Study, Nagesh Shukla, John Keast, Darek Ceglarek
Improved Workflow Modelling Using Role Activity Diagram-Based Modelling With Application To A Radiology Service Case Study, Nagesh Shukla, John Keast, Darek Ceglarek
Nagesh Shukla
The modelling of complex workflows is an important problem-solving technique within healthcare settings. However, currently most of the workflow models use a simplified flow chart of patient flow obtained using on-site observations, groupbased debates and brainstorming sessions, together with historic patient data. This paper presents a systematic and semi-automatic methodology for knowledge acquisition with detailed process representation using sequential interviews of people in the key roles involved in the service delivery process. The proposed methodology allows the modelling of roles, interactions, actions, and decisions involved in the service delivery process. This approach is based on protocol generation and analysis techniques …
The Feasibility Study And Characterziation Of A Two-Dimensional Diode Array In “Magic Phantom” For High Dose Rate Brachytherapy Quality Assurance, A Espinoza, B Beeksma, M Petasecca, I Fuduli, C Porumb, D L. Cutajar, S Corde, M A. Jackson, M Lf Lerch, Anatoly B. Rosenfeld
The Feasibility Study And Characterziation Of A Two-Dimensional Diode Array In “Magic Phantom” For High Dose Rate Brachytherapy Quality Assurance, A Espinoza, B Beeksma, M Petasecca, I Fuduli, C Porumb, D L. Cutajar, S Corde, M A. Jackson, M Lf Lerch, Anatoly B. Rosenfeld
Anthony A Espinoza Mr
High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly 192Ir with an air KERMA strength range between 20 000 and 40 000 U, where 1 U = 1 uGy m2/h in air) through applicators directly into the patient's prescribed region of treatment. Due to the obvious ramifications of incorrect treatment while using such an active source, it is essential that there are methods for quality assurance (QA) that can directly and accurately verify the treatment plan and the …
Laboratory Study Of Small-Strain Behavior Of A Compacted Silty Sand, Ana Heitor, Buddhima Indraratna, Cholachat Rujikiatkamjorn
Laboratory Study Of Small-Strain Behavior Of A Compacted Silty Sand, Ana Heitor, Buddhima Indraratna, Cholachat Rujikiatkamjorn
Cholachat Rujikiatkamjorn
Small-strain behavior is a key indicator for assessing the performance of compacted fills. Compaction conditions, i.e., initial moisture content and applied energy, govern compaction effectiveness and thus, the structure and matric suction of compacted soil. This paper presents an experimental study of the small-strain behavior of compacted silty sand prepared with different compaction conditions. Specimens with varying initial moisture contents and compaction energies were tested with bender elements to determine the small-strain shear modulus (G0), while the post-compaction matric suction was measured using the filter paper method and tensiometer. The experimental data suggest a pronounced relationship between G0 and the …
Laboratory Study Of Small-Strain Behavior Of A Compacted Silty Sand, Ana Heitor, Buddhima Indraratna, Cholachat Rujikiatkamjorn
Laboratory Study Of Small-Strain Behavior Of A Compacted Silty Sand, Ana Heitor, Buddhima Indraratna, Cholachat Rujikiatkamjorn
Buddhima Indraratna
Small-strain behavior is a key indicator for assessing the performance of compacted fills. Compaction conditions, i.e., initial moisture content and applied energy, govern compaction effectiveness and thus, the structure and matric suction of compacted soil. This paper presents an experimental study of the small-strain behavior of compacted silty sand prepared with different compaction conditions. Specimens with varying initial moisture contents and compaction energies were tested with bender elements to determine the small-strain shear modulus (G0), while the post-compaction matric suction was measured using the filter paper method and tensiometer. The experimental data suggest a pronounced relationship between G0 and the …
The Feasibility Study And Characterziation Of A Two-Dimensional Diode Array In “Magic Phantom” For High Dose Rate Brachytherapy Quality Assurance, A Espinoza, B Beeksma, M Petasecca, I Fuduli, C Porumb, D L. Cutajar, S Corde, M A. Jackson, M Lf Lerch, Anatoly B. Rosenfeld
The Feasibility Study And Characterziation Of A Two-Dimensional Diode Array In “Magic Phantom” For High Dose Rate Brachytherapy Quality Assurance, A Espinoza, B Beeksma, M Petasecca, I Fuduli, C Porumb, D L. Cutajar, S Corde, M A. Jackson, M Lf Lerch, Anatoly B. Rosenfeld
Stéphanie Corde
High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly 192Ir with an air KERMA strength range between 20 000 and 40 000 U, where 1 U = 1 uGy m2/h in air) through applicators directly into the patient's prescribed region of treatment. Due to the obvious ramifications of incorrect treatment while using such an active source, it is essential that there are methods for quality assurance (QA) that can directly and accurately verify the treatment plan and the …
Similarity-Based Search For Model Checking: A Pilot Study With Java Pathfinder, Elmin Ibrahimov, Jixing Wang, Zhiquan Zhou
Similarity-Based Search For Model Checking: A Pilot Study With Java Pathfinder, Elmin Ibrahimov, Jixing Wang, Zhiquan Zhou
Dr Zhiquan Zhou
When a model checker cannot explore the entire state space because of limited resources, model checking becomes a kind of testing with an attempt to find a failure (violation of properties) quickly. We consider two state sequences in model checking: (i) the sequence in which new states are generated, and (ii) the sequence in which the states generated in sequence (i) are checked for property violation. We observe that neighboring states in sequence (i) often have similarities in certain ways. Based on this observation we propose a search strategy, which generates sequence (ii) in such a way that similar states …
Dynamic Characteristics Of A Hybrid Microgrid With Inverter And Non- Inverter Interfaced Renewable Energy Sources: A Case Study, A V. Jayawardena, L G. Meegahapola, S Perera, D A. Robinson
Dynamic Characteristics Of A Hybrid Microgrid With Inverter And Non- Inverter Interfaced Renewable Energy Sources: A Case Study, A V. Jayawardena, L G. Meegahapola, S Perera, D A. Robinson
Dr Lasantha G Meegahapola
Microgrids are becoming important constituents of electric power distribution networks. Microgrids are typically comprised of both inverter interfaced (e.g. double-fed induction generator (DFIG), solar-photovoltaic (PV) system) and non-inverter interfaced (e.g. synchronous generator) renewable energy generators (REGs), hence their dynamic characteristics are significantly different from the conventional grids comprised of centralised synchronous generators. Different inherent characteristics of REGs, power dispatch levels, relative REG capacities, and external grid characteristics are some of the important features of significant interest in relation to microgrid dynamic behaviour. For this study a microgrid model was developed in DIgSILENT Power Factory based on the IEEE-13 bus system …
The Feasibility Study And Characterziation Of A Two-Dimensional Diode Array In “Magic Phantom” For High Dose Rate Brachytherapy Quality Assurance, A Espinoza, B Beeksma, M Petasecca, I Fuduli, C Porumb, D L. Cutajar, S Corde, M A. Jackson, M Lf Lerch, Anatoly B. Rosenfeld
The Feasibility Study And Characterziation Of A Two-Dimensional Diode Array In “Magic Phantom” For High Dose Rate Brachytherapy Quality Assurance, A Espinoza, B Beeksma, M Petasecca, I Fuduli, C Porumb, D L. Cutajar, S Corde, M A. Jackson, M Lf Lerch, Anatoly B. Rosenfeld
Michael L.F. Lerch
High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly 192Ir with an air KERMA strength range between 20 000 and 40 000 U, where 1 U = 1 uGy m2/h in air) through applicators directly into the patient's prescribed region of treatment. Due to the obvious ramifications of incorrect treatment while using such an active source, it is essential that there are methods for quality assurance (QA) that can directly and accurately verify the treatment plan and the …
The Study Of Flood Hydraulics Before The Building Of Maroon Dam By Hec-Ras, Maskingam And Muskingum - Cunge Method, Mohammad Hossein Naghshine, Farhad Fakheri Raof, Ali Khoshrftar
The Study Of Flood Hydraulics Before The Building Of Maroon Dam By Hec-Ras, Maskingam And Muskingum - Cunge Method, Mohammad Hossein Naghshine, Farhad Fakheri Raof, Ali Khoshrftar
Farhad Fakheri Raof
Routing of rivers which flow through the important areas is from the important river engineering measures. In this research, flood routing in the Maroon River has been studied bases on hydrometric stations between Behbahan and Chamnezam. Todays, numerical computer methods are developed for the Cent and Nante equations. The HEC-RAS software and Muskingum and Muskingum - corners methods are used for this work. HEC-RAS model with solving of dynamic equations motion simulates unsteady flow in the form of onedimensional flow in open channels. After calibration and testing, the results of these methods were compared.So, the HEC-RAS model results considerably better …