Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Engineering

Ultrasonic Flow Meter Calibration Via The Internet Using An Analog-To-Digital Converter, Aliev Ravshan, A.U. Djalilov Jun 2024

Ultrasonic Flow Meter Calibration Via The Internet Using An Analog-To-Digital Converter, Aliev Ravshan, A.U. Djalilov

Chemical Technology, Control and Management

The purpose of scientific research work is remote control of improving the metrological properties of the water flow measuring device. Therefore, the Arduino platform with an additional ESP8266 NodeMcu v3 and analog-to-digital converter, module was installed in the scientific article for automatic calibration/checking of ultrasonic flow meters used in irrigation networks. The module is integrated into a 32-bit microcontroller with low power consumption. The ESP8266 NodeMcu v3 module operates at 80 and 160 MHz clock frequencies, supports real-time operating system (RTOS), built-in Wi-Fi, and has a microstrip antenna on board. Through this, the data exchange between the computing equipment and …


Calculation Of Hydraulic Resistance Of A Tubular-Gridse Nozzle With Spiral Turbulizers, Nurmukhamedov Habibulla Sagdullaevich, Mavlonov Elbek Tulkinovich, S.Kh. Nishonova, Kh.S. Nurmukhamedov Feb 2024

Calculation Of Hydraulic Resistance Of A Tubular-Gridse Nozzle With Spiral Turbulizers, Nurmukhamedov Habibulla Sagdullaevich, Mavlonov Elbek Tulkinovich, S.Kh. Nishonova, Kh.S. Nurmukhamedov

Chemical Technology, Control and Management

The article presents the results of an experimental study on the hydraulic resistance of a tubular-grid nozzle made of smooth pipes and pipes with spiral turbulators. Experiments were carried out with nozzles made of smooth pipes and pipes with turbulators. Spiral turbulators are placed discretely with a step t/d=0,3125-0,9375 and installed on a tube sheet in a checkerboard pattern with a step s/d=1,15-10. Experimental studies were carried out with air flow in the transition region.

It has been established that with increasing numerical values of the dimensionless parameter s/d, the resistance of the pipe package decreases from 1,3 to 1,8 …


Effect Of Degumming Methods On Quality Of Rapeseed And Sunflower Oils, Oybek Zufarov, Kamar Serkayev Dec 2023

Effect Of Degumming Methods On Quality Of Rapeseed And Sunflower Oils, Oybek Zufarov, Kamar Serkayev

Chemical Technology, Control and Management

This study analyzed the effects of different degumming methods on the rapeseed and sunflower oils. Water degumming, acid degumming, and TOP degumming have been employed to reduce the content of phospholipids (P), calcium (Ca), magnesium (Mg), and iron (Fe) in the oils. After water degumming, the number of total phospholipids had decreased significantly (more than 80%) in both oils. Acid degumming further lowered phospholipids content more than 96%, and the protection factor (PF-indicates oxidative stability of oils) of values for rapeseed and sunflower oils have been 1.39 and 1.26, respectively. TOP degumming had effectively removed Fe, the amount of Fe …


Mathematical Description Of A Bleach Impregnation Reservoir, Bekobod Ibragimov Apr 2023

Mathematical Description Of A Bleach Impregnation Reservoir, Bekobod Ibragimov

Chemical Technology, Control and Management

This article discusses the issues of constructing a mathematical model of the technological process of bleaching textile materials in an impregnating reservoir using the heat balance equation, on the basis of which a qualitative analysis of the dynamic properties of an object has been carried out in order to create highly efficient control systems with the use of energy-saving technologies. While constructing a mathematical model characterizing the established and non-established modes of the control object (impregnating reservoir) used changes in heat flow and mass velocity of the incoming tissue. An algorithm for constructing a mathematical model of the process of …


Analysis Of Errors Of The Ultrasonic Level And Increasing The Accuracy Of Measuring The Level Of Liquid Materials In Non-Stationary Media, Azamat Alijonovich Yusupov Aug 2021

Analysis Of Errors Of The Ultrasonic Level And Increasing The Accuracy Of Measuring The Level Of Liquid Materials In Non-Stationary Media, Azamat Alijonovich Yusupov

Chemical Technology, Control and Management

This article is devoted to the analysis of the total error of an ultrasonic level meter designed to measure the level of liquid materials in order to improve the accuracy of the measuring system in tanks. The components of the total error of the process of measuring transformation of the liquid level are determined and the analysis of the main characteristics is carried out, to reduce the random error of the measurement system, the task of ensuring the accuracy of measurement and control of the level using an ultrasonic level gauge is presented, by averaging the measurement results when calculating …