Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 9 of 9

Full-Text Articles in Engineering

Uranium Holdup Mass Quantification By Hybrid Gamma Imaging, Blake R. Montz Dec 2022

Uranium Holdup Mass Quantification By Hybrid Gamma Imaging, Blake R. Montz

Masters Theses

Accurate quantification of uranium holdup is crucial in the efficient operation of many processing facilities involved with special nuclear material (SNM). The varying shapes and sizes of holdup deposits can make accurate quantification a challenge. The most common approach is the Generalized Geometry Holdup (GGH) method which simplifies the shape of the deposit to a point, line, or area source. Although the GGH method is quick and easy to implement, the oversimplifying assumptions can lead to systematic uncertainties as high as 50%. The research presented here is exploring gamma-ray imaging as a more accurate method of quantifying deposits. A PHDs …


Component Monitoring Strategies For Ipwr Plant Systems During Operational Transients, Matthew S. Scott Dec 2022

Component Monitoring Strategies For Ipwr Plant Systems During Operational Transients, Matthew S. Scott

Masters Theses

Small modular reactors (SMRs) are currently at the forefront of the nuclear industry as potential next stage in nuclear energy production. Implementing a new reactor technology in a commercial setting contains many challenges in terms of maintaining safety and regulatory standards since all of the regulatory framework is based on the traditional PWR design. One benefit of the SMR design is the increased ability to load-follow to meet the constant changes in grid demand. This type of operational strategy introduces changes into the system that impacts the operational lifespan of system components due to increased degradation. Since there are no …


Development Of A Low-Dose Radiation Therapy Device For Acute Respritory Distress Syndrome, Thomas Heath Davis Dec 2022

Development Of A Low-Dose Radiation Therapy Device For Acute Respritory Distress Syndrome, Thomas Heath Davis

Masters Theses

This research focuses on the development of a low dose radiotherapy (LD-RT) device for treatment of acute respiratory distress syndrome (ARDS), a respiratory illness that affects millions of people a year. The use of orthovoltage (200 – 500 keV) X-ray energy provides many advantages over traditional radiotherapy delivery with linear accelerators, such as low cost and greater accessibility. In addition, X-ray tubes have been shown throughout history to provide good treatment outcomes for pneumonia, and research has shown LD-RT to be just as effective with ARDS. This proposal summarizes my efforts in determining the dosimetric properties of a LD-RT system …


Fire Simulation And Analysis Of A Switchgear Cabinet Fire And Its Effects On Cable Trays, Yalcin Meraki Aug 2022

Fire Simulation And Analysis Of A Switchgear Cabinet Fire And Its Effects On Cable Trays, Yalcin Meraki

Masters Theses

Switchgear rooms are crucial in containing essential equipment such as cabinets and cable trays in case of a possible fire. There are three fire model classes which are algebraic models, zone model, and computation fluid dynamics model (CFD). PyroSim software, a visual user interface for the Fire Dynamics Simulator (FDS) developed at the National Institute of Standards and Technology (NIST), was used for simulation by using the CFD. Two different 464 kW and 1002 kW heat release rate (HRR) values were used under the same conditions for the fire scenario. By considering a fire scenario, the fire ignited due to …


Enigma - Ongoing Development Towards Novel Beta-Decay Spectroscopy Station At Isolde, Philipp Wagenknecht May 2022

Enigma - Ongoing Development Towards Novel Beta-Decay Spectroscopy Station At Isolde, Philipp Wagenknecht

Masters Theses

Beta decay and collinear laser spectroscopy are proven efficient tools to study nuclear structure far from stability. Two areas of significance are investigations into nuclear deformation and shape coexistence, as well as delayed neutron emissions used in nuclear energy applications. This contribution presents the ongoing development towards a novel beta-decay spectroscopy station for the VITO experiment at CERN’s radioactive ion beam facility ISOLDE. The setup will utilize both collinear laser spectroscopy and beta-decay spectroscopy to measure the energy and spin-parities of the ground and excited states of radioactive beams. Initial designs of the support structure, magnetic field, and detector array …


Validation Of Relap5-3d For Transient Simulation Of Lead-Lithium Systems For Fusion Applications, Nicholas Akira Meehan May 2022

Validation Of Relap5-3d For Transient Simulation Of Lead-Lithium Systems For Fusion Applications, Nicholas Akira Meehan

Masters Theses

With increasing development in fusion technology including the construction and subsequently planned experimental campaign of the International Thermonuclear Experimental Reactor (ITER), validation must be performed for simulation tools used in the design, development, and licensing of future commercial fusion systems. This thesis contains several validation studies for transient simulation of lead-lithium eutectic (PbLi) systems using the RELAP5-3D code. This validation analysis is performed initially using models of systems without the influence of a magnetic field to inspect heat transfer and pressure drop phenomena. The validation study then uses models of systems under the influence of a magnetic field to inspect …


Meta-Heuristic Optimization Techniques For The Production Of Medical Isotopes Through Special Target Design, Cameron Ian Salyer May 2022

Meta-Heuristic Optimization Techniques For The Production Of Medical Isotopes Through Special Target Design, Cameron Ian Salyer

Masters Theses

Medical isotopes are used for a variety of different diagnostic and therapeutic purposes Ruth (2008). Due to recent newly discovered applications, their production has become rapidly more scarce than ever before Charlton (2019). Therefore, more efficient and less time consuming methods are of interest for not only the industry’s demand, but for the individuals who require radio-isotope procedures. Currently, the primary source of most medical isotopes used today are provided by reactor and cyclotron irradiation techniques, followed by supplemental radio-chemical separations Ruth (2008). Up until this point, target designs have been optimized by experience, back of the envelope calculations, and …


Development Of Codoped Cesium Iodide Scintillators For Medical Imaging Applications, Everett M. Cavanaugh May 2022

Development Of Codoped Cesium Iodide Scintillators For Medical Imaging Applications, Everett M. Cavanaugh

Masters Theses

Cesium iodide has a rich history of use as a scintillating material. CsI finds use in a variety of fields, but it is primarily used in radiography, tomography, and geological exploration. Of the three common variants of CsI, thallium doped CsI is by far the most widely used among these applications. It possesses favorable physical characteristics like a high density and high effective Z and exhibits high light output at room temperature. Despite how great CsI scintillators may be on paper, they have an Achilles heel: afterglow. CsI:Tl has significant afterglow which leads to imaging artifacts that can be difficult …


Design And Evaluation Of A Unique Weighted-Sum-Based Anger Camera, Matthew W. Seals May 2022

Design And Evaluation Of A Unique Weighted-Sum-Based Anger Camera, Matthew W. Seals

Masters Theses

Anger camera imaging technology has become widely popular for neutron diffraction imaging due to recent shortages in Helium-3 (He-3). Research into neutron diffraction optimized Anger camera by the Oak Ridge National Laboratory (ORNL) detectors group has provided an alternative to He-3 Tube-based detectors with a high-resolution Anger camera. However, the cost of these high-resolution Anger camera technology can make it less attractive than He-3 tubes when a large Field of View (FOV) is desired. Currently, there is a need for a lower-cost alternative to this high-resolution anger camera. Further applications for Anger camera have become of interest with the advent …