Full-Text Articles in Engineering

Automated Identification Of Tumor Microscopic Morphology Based On Macroscopically Measured Scatter Signatures, Pilar Beatriz Garcia-Allende, Venkataramanan Krishnaswamy, P Jack Hoopes, Kimberley S. Samkoe, Olga M. Conde, Brian W. Pogue May 2009

Automated Identification Of Tumor Microscopic Morphology Based On Macroscopically Measured Scatter Signatures, Pilar Beatriz Garcia-Allende, Venkataramanan Krishnaswamy, P Jack Hoopes, Kimberley S. Samkoe, Olga M. Conde, Brian W. Pogue

Dartmouth Scholarship

An automated algorithm and methodology is presented to identify tumor-tissue morphologies based on broadband scatter data measured by raster scan imaging of the samples. A quasi-confocal reflectance imaging system was used to directly measure the tissue scatter reflectance in situ, and the spectrum was used to identify the scattering power, amplitude, and total wavelength-integrated intensity. Pancreatic tumor and normal samples were characterized using the instrument, and subtle changes in the scatter signal were encountered within regions of each sample. Discrimination between normal versus tumor tissue was readily performed using a K-nearest neighbor classifier algorithm. A similar approach worked …


Vesicles In Poiseuille Flow, Gerrit Danker, Petia M. Vlahovska, Chaouqi Misbah Apr 2009

Vesicles In Poiseuille Flow, Gerrit Danker, Petia M. Vlahovska, Chaouqi Misbah

Dartmouth Scholarship

Blood microcirculation critically depends on the migration of red cells towards the flow centerline. We identify theoretically the ratio of the inner over the outer fluid viscosities λ as a key parameter. At low λ, the vesicle deforms into a tank-treading ellipsoid shape far away from the flow centerline. The migration is always towards the flow centerline, unlike drops. Above a critical λ, the vesicle tumbles or breaths and migration is suppressed. A surprising coexistence of two types of shapes at the centerline, a bulletlike and a parachutelike shape, is predicted.


A Fully Automated Non-External Marker 4d-Ct Sorting Algorithm Using A Serial Cine Scanning Protocol, Greg Carnes, Stewart Gaede, Edward Yu, Jake Van Dyk, Jerry Battista, Ting-Yim Lee Apr 2009

A Fully Automated Non-External Marker 4d-Ct Sorting Algorithm Using A Serial Cine Scanning Protocol, Greg Carnes, Stewart Gaede, Edward Yu, Jake Van Dyk, Jerry Battista, Ting-Yim Lee

Edward Yu

Current 4D-CT methods require external marker data to retrospectively sort image data and generate CT volumes. In this work we develop an automated 4D-CT sorting algorithm that performs without the aid of data collected from an external respiratory surrogate. The sorting algorithm requires an overlapping cine scan protocol. The overlapping protocol provides a spatial link between couch positions. Beginning with a starting scan position, images from the adjacent scan position (which spatial match the starting scan position) are selected by maximizing the normalized cross correlation (NCC) of the images at the overlapping slice position. The process was continued by 'daisy …


The Use Of Ct Density Changes At Internal Tissue Interfaces To Correlate Internal Organ Motion With An External Surrogate, Stewart Gaede, Gregory Carnes, Edward Yu, Jake Van Dyk, Jerry Battista, Ting-Yim Lee Jan 2009

The Use Of Ct Density Changes At Internal Tissue Interfaces To Correlate Internal Organ Motion With An External Surrogate, Stewart Gaede, Gregory Carnes, Edward Yu, Jake Van Dyk, Jerry Battista, Ting-Yim Lee

Edward Yu

The purpose of this paper is to describe a non-invasive method to monitor the motion of internal organs affected by respiration without using external markers or spirometry, to test the correlation with external markers, and to calculate any time shift between the datasets. Ten lung cancer patients were CT scanned with a GE LightSpeed Plus 4-Slice CT scanner operating in a ciné mode. We retrospectively reconstructed the raw CT data to obtain consecutive 0.5 s reconstructions at 0.1 s intervals to increase image sampling. We defined regions of interest containing tissue interfaces, including tumour/lung interfaces that move due to breathing …