3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner Jul 2015

3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner

Richard A. Malthaner

The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the …


3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner Jul 2015

3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner

Richard A. Malthaner

The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the …


A Fully Automated Non-External Marker 4d-Ct Sorting Algorithm Using A Serial Cine Scanning Protocol, Greg Carnes, Stewart Gaede, Edward Yu, Jake Van Dyk, Jerry Battista, Ting-Yim Lee Apr 2009

A Fully Automated Non-External Marker 4d-Ct Sorting Algorithm Using A Serial Cine Scanning Protocol, Greg Carnes, Stewart Gaede, Edward Yu, Jake Van Dyk, Jerry Battista, Ting-Yim Lee

Edward Yu

Current 4D-CT methods require external marker data to retrospectively sort image data and generate CT volumes. In this work we develop an automated 4D-CT sorting algorithm that performs without the aid of data collected from an external respiratory surrogate. The sorting algorithm requires an overlapping cine scan protocol. The overlapping protocol provides a spatial link between couch positions. Beginning with a starting scan position, images from the adjacent scan position (which spatial match the starting scan position) are selected by maximizing the normalized cross correlation (NCC) of the images at the overlapping slice position. The process was continued by 'daisy …


In Vivo Ultrasonic Attenuation Slope Estimates For Detecting Cervical Ripening In Rats: Preliminary Results, Timothy A. Bigelow, Barbara L. Mcfarlin, William D. O'Brien Jr., Michael L. Oelze Mar 2008

In Vivo Ultrasonic Attenuation Slope Estimates For Detecting Cervical Ripening In Rats: Preliminary Results, Timothy A. Bigelow, Barbara L. Mcfarlin, William D. O'Brien Jr., Michael L. Oelze

Timothy A. Bigelow

To effectively postpone preterm birth, cervical ripening needs to be detected and delayed. As the cervix ripens, the spacing between the collagen fibers increases and fills with water, hyaluronan, decorin, and enzymes suggesting that the ultrasonic attenuation of the cervix should decrease. The decrease in ultrasonic attenuation may be detectable, leading to an effective means of detecting cervical ripening. Herein, the traditional attenuation slope-estimation algorithm based on measuring the downshift in center frequency of the ultrasonic backscattered signal with propagation depth was modified and applied to the cervix of rats. The modified algorithm was verified using computer simulations and an …


3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner Jan 2007

3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner

Edward Yu

The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the …