Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- Western University (7)
- University of Kentucky (3)
- The University of Akron (2)
- University of Wisconsin Milwaukee (2)
- Washington University in St. Louis (2)
-
- Clemson University (1)
- Embry-Riddle Aeronautical University (1)
- Louisiana State University (1)
- University of Arkansas, Fayetteville (1)
- University of Connecticut (1)
- University of Louisville (1)
- University of South Florida (1)
- University of Tennessee, Knoxville (1)
- West Virginia University (1)
- Wilfrid Laurier University (1)
- Publication Year
- Publication
-
- Electronic Thesis and Dissertation Repository (7)
- McKelvey School of Engineering Theses & Dissertations (2)
- Theses and Dissertations (2)
- Williams Honors College, Honors Research Projects (2)
- All Dissertations (1)
-
- Biomedical Engineering Undergraduate Honors Theses (1)
- Doctoral Dissertations and Master's Theses (1)
- Electronic Theses and Dissertations (1)
- Graduate Theses, Dissertations, and Problem Reports (1)
- LSU Doctoral Dissertations (1)
- Master's Theses (1)
- Masters Theses (1)
- Theses and Dissertations (Comprehensive) (1)
- Theses and Dissertations--Biomedical Engineering (1)
- Theses and Dissertations--Mechanical Engineering (1)
- Theses and Dissertations--Rehabilitation Sciences (1)
- USF Tampa Graduate Theses and Dissertations (1)
Articles 1 - 26 of 26
Full-Text Articles in Engineering
Effect Of Amputation On Muscle Structure Properties In A Rabbit Model, Roy Caleb Stubbs
Effect Of Amputation On Muscle Structure Properties In A Rabbit Model, Roy Caleb Stubbs
Masters Theses
After amputation, muscles in the residual limb are detached from their insertion points and no longer span the missing joints. Our objective was to quantify the effect of amputation-induced disuse on residual muscle structure, an indirect indicator of muscle force-generating capacity. One hind paw was surgically removed at the ankle joint of ten rabbits. At two weeks (n=5) and 4 weeks (n=5) post-amputation and for select muscles (gastrocnemius, soleus, tibialis cranialis, extensor digitorum, and flexor digitorum superficialis), we measured and computed several muscle structure properties. Additionally, we qualitatively assessed the muscle fiber appearance of histological samples at each timepoint. At …
Amphisbaenian Head Movement And Burrowing Forces In Damp Granular Media, Jacob Newell
Amphisbaenian Head Movement And Burrowing Forces In Damp Granular Media, Jacob Newell
Williams Honors College, Honors Research Projects
Damp granular media is a difficult environment to study because it is both practically complex and it lacks equations which fully describe its behavior. In this study, an oscillatory lateral head movement and its effects while penetrating damp granular media were tested using a robophysical model. This experimental research was inspired by the burrowing behavior of the clade Amphisbaenia, a group of usually limbless squamates that employ a variety of different burrowing behaviors, but it can apply to a wide range of burrowers. This research could help with both human burrowing technologies and the further investigation of animal behaviors.
Development And Application Of 3d Kinematic Methodologies For Biomechanical Modelling In Adaptive Sports And Rehabilitation, Anne Marie Severyn
Development And Application Of 3d Kinematic Methodologies For Biomechanical Modelling In Adaptive Sports And Rehabilitation, Anne Marie Severyn
All Dissertations
Biomechanical analysis is widely used to assess human movement sciences, specifically using three-dimensional motion capture modelling. There are unprecedented opportunities to increase quantitative knowledge of rehabilitation and recreation for disadvantaged population groups. Specifically, 3D models and movement profiles for human gait analysis were generated with emphasis on post-stroke patients, with direct model translation to analyze equivalent measurements while horseback riding in use of the alternative form of rehabilitation, equine assisted activities and therapies (EAAT) or hippotherapy (HPOT). Significant improvements in gait symmetry and velocity were found within an inpatient rehabilitation setting for patients following a stroke, and the developed movement …
Effects Of Seat And Axle Position On Pain, Pathology, And Independence In Pediatric Manual Wheelchair Users With Spinal Cord Injury, Hannah Frank
Theses and Dissertations
Manual wheelchair (MWC) users with spinal cord injury (SCI) rely heavily on their upperextremities to complete daily occupations. Due to repetitive shoulder use during wheelchair mobility and propulsion, MWC users are at greater risk of shoulder pain and shoulder pathology, and thus decreased independence, and lower quality of life. The relative fit of the wheelchair and its parameters are critical and can further impact the user’s propulsion biomechanics. Parameters such as seat angle and axle position may put the user in detrimental shoulder positions for longer periods of time, impacting health outcomes even more. Although the effects of wheelchair setup …
Subject-Specific Musculoskeletal Modeling Of Hip Dysplasia Biomechanics, Ke Song
Subject-Specific Musculoskeletal Modeling Of Hip Dysplasia Biomechanics, Ke Song
McKelvey School of Engineering Theses & Dissertations
Developmental dysplasia of the hip (DDH) is characterized by abnormal bony anatomy, causes pain and functional limitations, and is a prominent risk factor for premature hip osteoarthritis. Although the pathology of DDH is believed to be mechanically-induced, little is known about how DDH anatomy alters hip biomechanics during activities of daily living, partly due to the difficulties with measuring hip muscle and joint forces. Musculoskeletal models (MSMs) are useful for dynamic simulations of joint mechanics, but the reliability of MSMs for DDH research is limited by an accurate model representation of the unique hip anatomy. To address such challenges, this …
In Vitro Analyses Of The Contributions Of The Hip Capsule To Joint Biomechanics, Emma Donnelly
In Vitro Analyses Of The Contributions Of The Hip Capsule To Joint Biomechanics, Emma Donnelly
Electronic Thesis and Dissertation Repository
Optimal management of the hip capsule during arthroscopic surgery has not been established. The impact of incisions made to the capsule during minimally invasive procedures on joint biomechanics, and whether repair provides any benefit, continue to be debated. The effectiveness of capsular repair to restore native kinematics may be insufficient. Therefore, a better understanding of joint behavior during various capsule conditions is needed. A new robotic system was used to analyze the effect of progressive capsulotomy incision and repairs on the behavior of a normal hip within range of motion (ROM) limits with respect to the intact joint. Complete repairs …
Biomechanically Inspired Assistive Technology To Restore Movement Of The Upper Limbs After Stroke, Ariel Thomas
Biomechanically Inspired Assistive Technology To Restore Movement Of The Upper Limbs After Stroke, Ariel Thomas
Graduate Theses, Dissertations, and Problem Reports
A stroke often damages the neural structures responsible for movement. Stroke is a heterogeneous disease, affecting each survivor differently. There are common motor features of a stroke, but even these features vary across time as an individual proceeds through different stages of recovery. The different ways in which stroke motor impairment can present itself are often overlooked, but these differences are fundamental to the understanding of the disease and its recovery. When motor assessments are capable of acquiring information necessary to parse out a detailed profile of each stroke case, this will lead to an improved neuromechanical understanding of the …
An Investigation On The Influences Of Radial Head Hemiarthroplasty Stem Fixation Techniques On Articular Mechanics, Jakub Szmit
An Investigation On The Influences Of Radial Head Hemiarthroplasty Stem Fixation Techniques On Articular Mechanics, Jakub Szmit
Electronic Thesis and Dissertation Repository
Radial head hemiarthroplasty design has been extensively studied with a focus on utilizing the geometrical characteristics of the native radial dish as a guide of implant placement and design. Although implant design has been studied, optimal radial head implant fixation technique remains unknown. This thesis focused on the effect of stem fit on radiocapitellar contact mechanics, using both finite element and experimental bench-top approaches. Additionally, investigation into the impact of varus/valgus malalignment of the radial head in both the native state and following hemiarthroplasty was conducted. It was found that loose fitting a smooth stem axisymmetric radial head implant through …
Neuromotor Control Of The Hand During Smartphone Manipulation, Prasanna Kumar Acharya
Neuromotor Control Of The Hand During Smartphone Manipulation, Prasanna Kumar Acharya
LSU Doctoral Dissertations
The primary focus of this dissertation was to understand the motor control strategy used by our neuromuscular system for the multi-layered motor tasks involved during smartphone manipulation. To understand this control strategy, we recorded the kinematics and multi-muscle activation pattern of the right limb during smartphone manipulation, including grasping with/out tapping, movement conditions (MCOND), and arm heights.
In the first study (chapter 2), we examined the neuromuscular control strategy of the upper limb during grasping with/out tapping executed with a smartphone by evaluating muscle-activation patterns of the upper limb during different movement conditions (MCOND). There was a change in muscle …
Atv Dynamics And Pediatric Rider Safety, James T. Auxier Ii
Atv Dynamics And Pediatric Rider Safety, James T. Auxier Ii
Theses and Dissertations--Biomedical Engineering
It has been observed through numerous academic and governmental agency studies that pediatric all-terrain vehicle ridership carries significant risk of injury and death. While no doubt valuable to safety, the post-hoc approach employed in these studies does little to explain the why and how behind the risk factors. Furthermore, there has been no prolonged, widespread, organized, and concerted effort to reconstruct and catalog the details and causes of the large (20,000+) number of ATV-related injuries that occur each year as has been done for road-based motor vehicle accidents. This dissertation takes the opposite approach from a meta-analysis and instead examines …
Improved Orthopaedic Repairs Through Mechanically Optimized, Adhesive Biomaterials, Stephen Wheeler Linderman
Improved Orthopaedic Repairs Through Mechanically Optimized, Adhesive Biomaterials, Stephen Wheeler Linderman
McKelvey School of Engineering Theses & Dissertations
Despite countless surgical advances over the last several decades refining surgical approaches, repair techniques, and tools to treat tendon and tendon-to-bone injuries, we are still left with repair solutions that rely on fairly crude underlying mechanical principles. Musculoskeletal soft tissues have evolved to transfer high loads by optimizing stress distribution profiles across the tissue at each length scale. However, instead of mimicking these natural load transfer mechanisms, conventional suture approaches are limited by high load transfer across only a small number of anchor points within tissue. This leads to stress concentrations at anchor points that often cause repair failure as …
How Infant Positioning Impacts Hip Motion And The Associated Implications For Babies With Hip Dysplasia, Lauren Buchele
How Infant Positioning Impacts Hip Motion And The Associated Implications For Babies With Hip Dysplasia, Lauren Buchele
Biomedical Engineering Undergraduate Honors Theses
Developmental dysplasia of the hip (DDH) refers to a group of disorders, ranging from slight instability (Grades 1-3) to a severe dislocation (Grade 4) of the femoral head from the acetabulum [1]. In order to treat DDH in infants, a reduction procedure and the use of a lower body harness to secure the hip joint as the bones and ligaments re-form properly is typically prescribed. The Pavlik Harness is currently the “gold-standard” orthopedic device used to place hips in proper positioning. However, little research has been reported on the biomechanical affects during use of these device types.
Although the Pavlik …
Development And Exploration Of A Z-Shaped Foot And Ankle Internal Fixation Plate, Rhaz Shaghaghi Paul, Ian Hames, Sean Rich
Development And Exploration Of A Z-Shaped Foot And Ankle Internal Fixation Plate, Rhaz Shaghaghi Paul, Ian Hames, Sean Rich
Williams Honors College, Honors Research Projects
This paper will detail the design process of developing a Z-shaped foot and ankle internal fixation plating system. Group 6: Plates for the Sole was made up of 5 team members, who worked together to accommodate their client’s request to complete a biomechanical analysis of a Z-Plate design and a construct a prototype. The Z-Plate’s purpose is to provide podiatrists with a new solution that can fit nicely on the small, irregular bones of the foot, while also remaining strong enough to withstand the forces and torques of the foot.
Connecting The Pieces: How Low Back Pain Alters Lower Extremity Biomechanics And Shock Attenuation In Active Individuals, Alexa Johnson
Connecting The Pieces: How Low Back Pain Alters Lower Extremity Biomechanics And Shock Attenuation In Active Individuals, Alexa Johnson
Theses and Dissertations--Rehabilitation Sciences
Low back pain in collegiate athletes has been reported at a rate of 37% from a wide array of sports including soccer, volleyball, football, swimming, and baseball. Whereas, in a military population the prevalence of low back pain is 70% higher than the general population. Compensatory movement strategies are often used as an attempt to reduce pain. Though compensatory movement strategies may effectively reduce pain, they are often associated with altered lower extremity loading patterns. Those who suffer from chronic low back pain tend to walk and run slower and with less trunk and pelvis coordination and variability. Individuals with …
Acromial Insufficiency Fractures In Reverse Total Shoulder Arthroplasty: A Biomechanical Study, Alicia Kerrigan
Acromial Insufficiency Fractures In Reverse Total Shoulder Arthroplasty: A Biomechanical Study, Alicia Kerrigan
Electronic Thesis and Dissertation Repository
Reverse total shoulder arthroplasty (RTSA) is increasingly utilized in the aging population, with a growing list of surgical indications including rotator cuff tear arthropathy, proximal humerus fractures, and revision arthroplasty. Acromial insufficiency fractures following RTSA are poorly understood, difficult to diagnose, and associated with inferior clinical outcomes. There is limited knowledge in the literature regarding the etiology of post-operative acromial fractures. The purpose of this study is to evaluate the role of implant parameters on acromial strain following RTSA.
Using a cadaveric model, a custom designed modular RTSA system was implanted that allowed for evaluation of modifiable parameters including glenoid …
The Development Of A Temporomandibular Force Simulator To Study Craniofacial Strain In-Vitro, Kenneth Kc Ip
The Development Of A Temporomandibular Force Simulator To Study Craniofacial Strain In-Vitro, Kenneth Kc Ip
Electronic Thesis and Dissertation Repository
An in-vitro musculoskeletal loading simulator was developed to replicate the internal forces of mastication, and then employed in a comparison of clinically relevant facial fracture repairs. Muscle forces are simulated by pneumatic pistons via 3D printed mounts that are reverse-engineered from CT scan to match muscle attachment sites, which are adhered to bone in order to simulate native stress distributions. Bite force and bone strain pattern of the craniofacial structure under load were measured using a force sensor and strain gauges respectively. In a series of five fresh-frozen cadaveric heads, it was found that strain patterns of the craniofacial structure …
Design And Analysis Of A 3d-Printed, Thermoplastic Elastomer (Tpe) Spring Element For Use In Corrective Hand Orthotics, Kevin Thomas Richardson
Design And Analysis Of A 3d-Printed, Thermoplastic Elastomer (Tpe) Spring Element For Use In Corrective Hand Orthotics, Kevin Thomas Richardson
Theses and Dissertations--Mechanical Engineering
This thesis proposes an algorithm that determine the geometry of 3D-printed, custom-designed spring element bands made of thermoplastic elastomer (TPE) for use in a wearable orthotic device to aid in the physical therapy of a human hand exhibiting spasticity after stroke. Each finger of the hand is modeled as a mechanical system consisting of a triple-rod pendulum with nonlinear stiffness at each joint and forces applied at the attachment point of each flexor muscle. The system is assumed quasi-static, which leads to a torque balance between the flexor tendons in the hand, joint stiffness and the design force applied to …
Computational Investigation Of The Biomechanics Of Babywearing In Regards To Developmental Dysplasia Of The Hip, Gaurav Girish
Computational Investigation Of The Biomechanics Of Babywearing In Regards To Developmental Dysplasia Of The Hip, Gaurav Girish
Doctoral Dissertations and Master's Theses
Developmental Dysplasia of the Hip (DDH) is a congenital condition where an infant’s hip socket is either loose or otherwise unstable. DDH causes a joint instability where the femoral head is not properly situated inside the acetabulum. Etiology of the condition is in part congenital and developmental, with a difference of DDH prevalence between ethnicities. Incidence of DDH is also in some part dependent on cultural practices and activities of the mother and child. The exact nature of this cultural incidence is not clearly understood. A computational approach is hypothesized to identify the impact of babywearing position on the healthy …
Biomechanical Testing Of An Exercise For Strengthening The Proximal Femur., Alyssa Osbourne
Biomechanical Testing Of An Exercise For Strengthening The Proximal Femur., Alyssa Osbourne
Electronic Theses and Dissertations
Based on the principles of cutting edge bone remodeling research, a unique therapeutic exercise device was designed specifically to improve bone quality at the most critical location of the proximal femur prone to fracture: the superior-lateral femoral neck where the fracture first initiates during a fall. The exercise/device is intended to work by inducing enough strain in the bone to stimulate the body’s natural bone remodeling mechanisms to increase bone density in the proximal femur and consequently prevent a fracture from arising if a fall to the side does occur.
In order to test the proposed exercise, experiments simulating the …
The Effect Of Twist On The Mechanical Properties Of The Intervertebral Disc, Maxine Harvey-Burgess
The Effect Of Twist On The Mechanical Properties Of The Intervertebral Disc, Maxine Harvey-Burgess
Theses and Dissertations (Comprehensive)
Introduction: Intervertebral disc (IVD) herniation is a common injury to the IVD and a frequent source of low back pain. IVD herniation occurs when the nucleus pulposus migrates through both the inter- and intralamellar matrices of the annulus fibrosus (AF). There are a number of mechanical risk factors associated with herniation, including repetitive flexion and twist. In vivo, twist combined with repetitive flexion has been associated with increased experience of low back pain and herniation. Additionally, in vitro, when repetitive flexion is combined with twist, IVD herniation occurs more easily than repetitive flexion alone. However, the mechanisms behind …
Markerless Radiostereogammetry Of The Shoulder Joint In Humans: Comparisons Of Scapulohumeral Kinematics Between Individuals With Healthy And Supraspinatus-Impaired Shoulders, Ashley N. Hannon
Electronic Thesis and Dissertation Repository
The purpose of this collection of studies was to further develop the knowledge of shoulder motion in order to better understand joint function through direct measurement of 3D scapulohumeral joint kinematics using a technique of high accuracy. Markerless, bi-planar fluoroscopic radiostereometric analysis using a generic shoulder model was developed in this thesis, reducing the amount of radiation exposure to subjects. The studies compared kinematic data of the scapulohumeral joint in six degrees of freedom with a precise, in-vivo measuring technique. Data were collected on young and older healthy individuals, individuals with a torn supraspinatus and post-surgical intervention.
Although this generic …
Biomechanical Joint Demands And Functional Outcomes During Manual Wheelchair Use In Pediatric Patients With Spinal Cord Injury, Christine M. Aurit
Biomechanical Joint Demands And Functional Outcomes During Manual Wheelchair Use In Pediatric Patients With Spinal Cord Injury, Christine M. Aurit
Theses and Dissertations
The biomechanical demands of the upper extremities (UEs) during pediatric manual wheelchair (MWC) use have not been fully explored. Children who use MWCs for mobility engage in a range of functional activities that may place large biomechanical demands on the UEs leading to a high risk on overuse injuries. This study aims to analyze the kinematics and kinetics of pediatric manual wheelchair use during propulsion, starting, stopping and weight relief tasks. Fourteen pediatric patients with spinal cord injury were recruited and data were collected using a 14-camera Vicon MX motion analysis system (Oxford Metric Group, Oxford, UK) and a SmartWheel …
The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari
The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari
Electronic Thesis and Dissertation Repository
Abstract:
The Effect of Fixation Plate Length on Spinal Instability Following Anterior Cervical Plate Fixation for the Repair of in Vitro Flexion-Distraction Injuries
Introduction: Anterior cervical decompression and fusion with a plate (ACDFP) is a commonly performed treatment following a traumatic injury to the subaxial cervical spine. The purpose of the presented work was to determine the biomechanical effect of plate length on cervical spine kinematic stability following ACDFP stabilization for a simulated traumatic injury.
Methods: Eleven fresh-frozen cadaveric C5-C6 and C6-C7 motion segments were examined in this study. To assess kinematics, flexibility testing was performed on each specimen …
Design And Development Of A Novel Expanding Pedicle Screw For Use In The Osteoporotic Lumbar Spine, Parham Rasoulinejad
Design And Development Of A Novel Expanding Pedicle Screw For Use In The Osteoporotic Lumbar Spine, Parham Rasoulinejad
Electronic Thesis and Dissertation Repository
Pedicle screws are commonly utilized in spinal surgery; however, traditional designs often do not provide adequate fixation in osteoporotic spines. The objective of this thesis was to develop a novel expanding screw for use in osteoporotic lumbar pedicles. Helical screws capable of expanding post insertion were built on a rapid prototype machine. A materials testing machine performed axial load to failure tests in both Sawbones and cadaveric specimens comparing the new design to traditional screws (rate = 10mm/min to 20 mm). Output parameters included yield load, ultimate load, stiffness, energy to failure and total energy. The expanding screw showed a …
Evaluation Of Transfer Technologies To Preserve Shoulder Function In Sci, Karen Michelle Mann
Evaluation Of Transfer Technologies To Preserve Shoulder Function In Sci, Karen Michelle Mann
USF Tampa Graduate Theses and Dissertations
This study investigated a series of independent unassisted and device-assisted transfers from a wheelchair to vehicle mock-up and vice versa while simultaneously capturing kinematic, kinetic and electromyographic (EMG) data of impaired volunteers. The study provides a venue for observation and evaluation of upper extremity (UE) joint stresses, muscular force and functional demands associated with transfers in persons with spinal cord injury (SCI) to ultimately prevent UE injury, minimize excessive stress, preserve functionality and limit pain. If people with SCI lose function of their UEs, due to pain and/or degeneration, they must then rely on others for everyday tasks.
Five paraplegic …
Automation Of Orthodontic Wire Tester For Performing Three Point Bending Tests, Adithya Venkatesan
Automation Of Orthodontic Wire Tester For Performing Three Point Bending Tests, Adithya Venkatesan
Master's Theses
Abstract
Understanding the biomechanical factors in orthodontics is important in order to improve the overall effectiveness of actual clinical treatment. An accurate method to study the threedimensional (3D) force systems and the resulting movements of teeth during orthodontic treatment is needed along with the understanding of the material properties of any orthodontic wire. Until recently, most of the orthodontic biomechanics literature was limited to twodimensional experimental studies. Recent advances in threedimensional computer modeling have also been developed but have been limited to the manual control of tooth movement. Overall, there is very little published evidence in the literature on the …