Open Access. Powered by Scholars. Published by Universities.®
- Keyword
Articles 1 - 10 of 10
Full-Text Articles in Engineering
A Collagen‐Glycosaminoglycan‐Fibrin Scaffold For Heart Valve Tissue Engineering Applications, Claire Brougham, Stefan Jockenhoevel, Thomas Flanagan, Fergal O'Brien
A Collagen‐Glycosaminoglycan‐Fibrin Scaffold For Heart Valve Tissue Engineering Applications, Claire Brougham, Stefan Jockenhoevel, Thomas Flanagan, Fergal O'Brien
Conference Papers
The field of heart valve biology and tissue engineering a heart valve continue to expand. The presentatio ns at this meeting reflect the advances made in both areas due to the multi-disciplinary approach taken by many laboratories.
Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …
Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …
Cutting Rate Effect On Temperature During Cortical Bone Sawing, Hamid Khalili Parsa, Ger Reilly, Brendan Mccormack
Cutting Rate Effect On Temperature During Cortical Bone Sawing, Hamid Khalili Parsa, Ger Reilly, Brendan Mccormack
Conference Papers
When bone is cut the occurrence of thermal damage to the bone is of major concern to the surgeon. If the temperature exceeds 44°C for longer than 1 min, bone repair is impaired (Eriksson et al, 1984) and necrosis may occur. Repeated use of cutting blades may reduce the cutting efficiency (Wevers et al, 1987; Toksvig-Larsen et al, 1992). Wevers et al also found that there is a greater force required to cut cortical bone using a blunt saw compared to new one.
Indentation Fracture Of Bovine Cortical Bone: Acoustic Emission Technique, Ashkan Safari, Ger Reilly, Brendan Mccormack
Indentation Fracture Of Bovine Cortical Bone: Acoustic Emission Technique, Ashkan Safari, Ger Reilly, Brendan Mccormack
Conference Papers
Indentation cutting may result in microcracking and main crack growth which was previously reported. In this study, we recorded the AE signals produced by cracking processes during cutting on cortical bone, measuring the cutting force and correlating between load-displacement curves and AE activities.
Analysis Of Indentation Loading Of Cortical Bone Using Acoustic Emission Techniques, Ashkan Safari, Ger Reilly, Brendan Mccormack
Analysis Of Indentation Loading Of Cortical Bone Using Acoustic Emission Techniques, Ashkan Safari, Ger Reilly, Brendan Mccormack
Conference Papers
In this study, we recorded the number of Acoustic emission (AE) hits and related AE energy during indentation fracture of cortical bone using a PAC PCI-2 card and pico sensor. A threshold value of 43dB was used to filter premature trigger due to background noise. Registered AE hits had more than one count (threshold crossing). Amplifier gain was set at 40dB with a (0.1-1) MHz band pass filter. 8mm cubes of cortical bones were indented in the longitudinal direction at constant crosshead speed of 1 mm min-1 using a large 2D, 50˚ wedge indenter. We hypothesised that signals occurring as …
Detection Of Microcracks During Bone Cutting Using Acoustic Emission Techniques, Ashkan Safari, Ger Reilly, Brendan Mccormack
Detection Of Microcracks During Bone Cutting Using Acoustic Emission Techniques, Ashkan Safari, Ger Reilly, Brendan Mccormack
Conference Papers
Surgeons may use a number of cutting instruments such as osteotomes and chisels to cut bone during operative procedures. The initial loading of cortical bone during the cutting process results in the formation of microcracks in the vicinity of the cutting zone with main crack propagation to failure occurring with continued loading; microcracking acts as a stimulus for main crack formation and has also been shown to occur during the propagation of the main crack. It has also been reported that Acoustic Emission (AE) is generated due to microcrack formation and crack growth, prior to, and during final fracture in …
An Experimental Technique For Measurement Of Heat Generated During Bone Sawing, Hamid Khalili Parsa, Ger Reilly, Brendan Mccormack
An Experimental Technique For Measurement Of Heat Generated During Bone Sawing, Hamid Khalili Parsa, Ger Reilly, Brendan Mccormack
Conference Papers
Orthopaedic bone cutting processes such as osteotomy and hip arthroplasty involve the cutting of one with the aid of various manual and powered cutting instruments including manual and powered bone saws. The extent of surgically induced bone necrosis at the point of the cutting tool and the bone is mainly due to the frictional heat generated by bone cutting. Bone necrosis has an impact on bone regeneration, and the rate of healing of the bone post operation. The threshold temperature for impaired regeneration of bone is in the range of 44°C to 47°C. Overheating also affects the sharpness life of …
Sequential Labelling And Acoustic Emission Analysis Of Damage Occurring In Cortical Bone During Indentation Cutting, Ger Reilly, Ashkan Safari, David Taylor, Brendan Mccormack
Sequential Labelling And Acoustic Emission Analysis Of Damage Occurring In Cortical Bone During Indentation Cutting, Ger Reilly, Ashkan Safari, David Taylor, Brendan Mccormack
Conference Papers
When a surgeon uses a wedge shaped blade or an osteotome to cut cortical bone during an operative procedure the bone will fail by a process of microcracking and primary crack propagation. It has previously been observed that crack propagation is dependent on the direction of cutting relative to the main axis of the bone. It has also been observed that microcracks occurring during fracture release acoustic signals that facilitate real-time monitoring of a cutting process. In these novel studies, we labelled damage accumulation during cutting of cortical bone using sequential chelating dyes and we correlated recorded AE signals during …
An Investigation Of The Heat Affected Zone In Cortical Bone Sawing, Hamid Khalili Parsa, Ger Reilly, Brendan Mccormack, Andrew Macey
An Investigation Of The Heat Affected Zone In Cortical Bone Sawing, Hamid Khalili Parsa, Ger Reilly, Brendan Mccormack, Andrew Macey
Conference Papers
Surgical procedures such as osteotomy and hip replacement involve the cutting of bone with the aid of various manual and powered cutting instruments including manual and powered bone saws. Frictional rubbing between the blade of the saw and the bone results in the generation of localised heating of the cut bone and increased cutting forces (Ark et al, 1997). Overheating in localised areas can cause bone necrosis and have an impact on the rate of healing of the bone post operation and overheating also affects the sharpness life of the blade. A review of the literature indicates that work has …