Experimental Energy Performance Of Open Cooling Towers Used Under Low And Variable Approach Conditions For Indirect Evaporative Cooling Of Buildings, Ben Costelloe, Donal Finn Jan 2003

Experimental Energy Performance Of Open Cooling Towers Used Under Low And Variable Approach Conditions For Indirect Evaporative Cooling Of Buildings, Ben Costelloe, Donal Finn

Articles

The success of chilled ceilings and displacement ventilation systems as a means of sensible cooling in buildings has prompted a review of evaporative cooling technology as an effective means of generating the required cooling water. When such cooling water is generated at low approach conditions (2–5 K), at the higher temperatures required in these systems (14–18°C), very high levels of availability result. In many north western European locations the levels of availability are such that the prospect of supplanting rather than simply supplementing the refrigeration system, for sensible cooling purposes, arises. The viability of the technique, however, largely depends on …


Air Intake Cooling Motor Vehicle Performance Enhancement, James Brunton, David Kennedy, John D. Kelleher Jan 2003

Air Intake Cooling Motor Vehicle Performance Enhancement, James Brunton, David Kennedy, John D. Kelleher

Articles

This research examined the practical effects of cooling the intake air, on the combustion characteristics of a modern motor vehicle operating under simulated road conditions as well as its subsequent impact on the environment. The cooling effect was achieved by taking a typical air conditioning rig as fitted to a modern motor vehicle and incorporating it into the induction system of the car. The test vehicle used was a 1993 Renault Safrane 2.0Vi standard passenger car that was modified as part of the research to facilitate the extraction of the required test information. A series of tests were conducted using …


Indirect Evaporative Cooling Potential In Air-Water Systems In Temperate Climates, Ben Costelloe, Donal Finn Jan 2003

Indirect Evaporative Cooling Potential In Air-Water Systems In Temperate Climates, Ben Costelloe, Donal Finn

Articles

Recent developments have prompted a review of evaporative cooling technology as an effective means of cooling modern deep plan buildings. Prominent among these developments is the success of high temperature sensible cooling systems, particularly, chilled ceilings, which require a supply of cooling water at 14–18 °C. Crucial to the success of evaporative cooling technology, as a significant means of cooling in modern applications, is the ability to generate cooling water, in an indirect circuit, at a temperature which closely approaches the ambient adiabatic saturation temperature (AST) or wet bulb temperature (WBT). Recent experimental research has demonstrated that it is technically …