Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering

Cleveland State University

Actuators

Articles 1 - 3 of 3

Full-Text Articles in Engineering

Application Of Active Magnetic Force Actuator For Control Of Flexible Rotor System Vibrations, Volodymyr Mykhaylyshyn Jan 2011

Application Of Active Magnetic Force Actuator For Control Of Flexible Rotor System Vibrations, Volodymyr Mykhaylyshyn

ETD Archive

The purpose of this work was to develop and experimentally demonstrate a novel approach to minimize lateral vibrations of flexible rotor. The applied feed forward control approach employed magnetic force actuator to inject a specially designed force to counteract the rotor unbalance force. By specific selection of frequency and phase as functions of the rotor running speed and rotor natural frequency, the proposed simplified injection waveform has been shown to be effective both in reducing the rotor's vibrations and for hardware implementation. A model of the test rig was constructed using the finite element (FE) method and was validated using …


Design And Validation Of A General Purpose Robotic Testing System For Musculoskeletal Applications, Lawrence D. Noble, Robb W. Colbrunn, Dong-Gil Lee, Antonie J. Van Den Bogert, Brian L. Davis Feb 2010

Design And Validation Of A General Purpose Robotic Testing System For Musculoskeletal Applications, Lawrence D. Noble, Robb W. Colbrunn, Dong-Gil Lee, Antonie J. Van Den Bogert, Brian L. Davis

Mechanical Engineering Faculty Publications

Orthopaedic research on in vitro forces applied to bones, tendons, and ligaments during joint loading has been difficult to perform because of limitations with existing robotic simulators in applying full-physiological loading to the joint under investigation in real time. The objectives of the current work are as follows: (1) describe the design of a musculoskeletal simulator developed to support in vitro testing of cadaveric joint systems, (2) provide component and system-level validation results, and (3) demonstrate the simulator’s usefulness for specific applications of the foot-ankle complex and knee. The musculoskeletal simulator allows researchers to simulate a variety of loading conditions …


Non-Collocation Problems In Dynamics And Control Of Mechanical Systems, Timothy M. Obrzut Jan 2009

Non-Collocation Problems In Dynamics And Control Of Mechanical Systems, Timothy M. Obrzut

ETD Archive

Characteristics of mechanical systems with non-collocated sensors and actuators are investigated. Transfer function zeros location as a function of sensor position, zero-pole interlacing, and re-location of zeros are discussed in a context of presented examples. Some of the presented examples involving non-collocation are supported by experimental data. A case study involving a high speed machining spindle is examined. The control problems associated with non-collocation are studied along with the methods to solve them