Atmospheric dispersion modeling

Articles 1 - 3 of 3

Full-Text Articles in Engineering

Zastosowanie Metody Obliczeniowo-Pomiarowej Do Oceny Stanu Zanieczyszczenia Powietrza W Nowym Sączu, Marian Mazur, Marek Bogacki, Robert Oleniacz Dec 1996

Zastosowanie Metody Obliczeniowo-Pomiarowej Do Oceny Stanu Zanieczyszczenia Powietrza W Nowym Sączu, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

Assessment of the state of air pollution in the urban area is a difficult and complex task. Depending on the method of assessment the procedure requires a comprehensive research and calculations of air emissions from all sources occurring in the area and the use of atmospheric dispersion models or large-scale implementation of direct measurements of air pollutant concentrations. Both of these methods may also be applied simultaneously to their mutual verification.

The article presents the results of such a comprehensive assessment of air pollution on the example of the city of Nowy Sacz (Poland). This involved determining the emissions of …


Kompleksowa Ocena Jakości Powietrza W Nowym Sączu Przy Pomocy Metody Obliczeniowo-Pomiarowej, Marian Mazur, Marek Bogacki, Robert Oleniacz Sep 1996

Kompleksowa Ocena Jakości Powietrza W Nowym Sączu Przy Pomocy Metody Obliczeniowo-Pomiarowej, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

The paper presents the results of a comprehensive assessment of air pollution in the city of Nowy Sącz (Poland). This involved determining the emissions of selected pollutants from various sources with their percentages of the total emission and immission on the area under consideration. As a result of measurement of concentrations of particulate matter and benzo(a)pyrene in several parts of the city were verified results of theoretical calculations and determined the size of the inflow of pollutants from outside the area in question.

English title: A comprehensive assessment of air quality in Nowy Sącz using computational and measuring methods.


Zanieczyszczenie Powietrza Kotliny Sądeckiej Przez Przemysł Elektrodowy, Marian Mazur, Marek Bogacki, Robert Oleniacz Feb 1996

Zanieczyszczenie Powietrza Kotliny Sądeckiej Przez Przemysł Elektrodowy, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

The article evaluates the impact of electrode industry (production of carbon and graphite electrodes in the plant Polgraph SA) on air quality in the Kotlina Sądecka valley and the city Nowy Sącz (Poland). The work presents completed so far environmental investments and the level of emissions of selected air pollutants characteristic of the analyzed facility, including PAHs emissions. Based on the modeling of the dispersion of pollutants in ambient air was determined the levels of pollutant concentrations in the air and location of most affected areas. The calculation results were compared with the results of direct measurements. Particular attention was …