Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 15 of 15

Full-Text Articles in Engineering

Simultaneous Measurement Of Gas Pressure And Temperature Using A Microbubble Resonator Combined With An Fbg, Ketan Dong, Ke Tian, Chuanzhen Zhao, Huibin Li, Jibo Yu, Angzhen Li, Xiaoling Sun, Elfed Lewis, Gerald Farrell, Pengfei Wang Jan 2023

Simultaneous Measurement Of Gas Pressure And Temperature Using A Microbubble Resonator Combined With An Fbg, Ketan Dong, Ke Tian, Chuanzhen Zhao, Huibin Li, Jibo Yu, Angzhen Li, Xiaoling Sun, Elfed Lewis, Gerald Farrell, Pengfei Wang

Conference Papers

We propose and demonstrate a microbubble resonator combined with a fiber Bragg grating (FBG) for simultaneous measurement of gas pressure and temperature. The approach used allows for very close proximity (<200 >μm) between the FBG and the microbubble resonator. The microbubble resonator is fabricated in a section of hollow-core fiber (HCF), spliced to a single-mode fiber (SMF) with a pre-inscribed FBG to form a single-ended open structure. Fresnel reflection from the HCF cleaved end means that broadband light is reflected backwards in the same direction as the Bragg wavelength from the FBG. A tapered fiber couples the reflected broadband light …


Sensing Of Multiple Parameters With Whispering Gallery Mode Optical Fiber Micro-Resonators, Arun Kumar Mallik Dr, Vishnan Kavungal, Gerald Farrell, Yuliya Semenova Jan 2019

Sensing Of Multiple Parameters With Whispering Gallery Mode Optical Fiber Micro-Resonators, Arun Kumar Mallik Dr, Vishnan Kavungal, Gerald Farrell, Yuliya Semenova

Conference Papers

Monitoring of multiple physical parameters, such as humidity, temperature, strain, concentrations of certain chemicals or gases in various environments is of great importance in many industrial applications both for minimizing adverse effects on human health as well as for maintaining production levels and quality of products. In this paper we demonstrate two different approaches to the design of multi-parametric sensors using coupled whispering gallery mode (WGM) optical fiber micro-resonators. In the first approach, a small array of micro-resonators is coupled to a single fiber taper, while in the second approach each of the micro-resonators within an array is coupled to …


Bluetooth Tracking Approach For User Assistance Based In Sequential Patterns Analysis., Aitor Arribas Velasco, John Mcgrory, Damon Berry Jan 2019

Bluetooth Tracking Approach For User Assistance Based In Sequential Patterns Analysis., Aitor Arribas Velasco, John Mcgrory, Damon Berry

Conference Papers

As a civilization, we are drowning in a raging torrent of data, of our own making, that is being harvested by our collective technologies and systems (e.g. Fitbit, phones). However, data itself is of no utility unless it is converted into beneficial knowledge. Design patterns have been shown to be a pragmatic solution to control and manage information flows and provide order and mean-ing to data within a given context. Assisting users within their daily activities has become a key aspect for modern Artificial Intelligence Systems. Neverthe-less, although the GPS technologies work well for outside location, indoor posi-tioning is still …


Miniaturized Switchless Pattern Reconfigurable Antenna Utilizing Spherical Modes Analysis, Adam Narbudowicz, Max Ammann, Nicola Marchetti Jan 2018

Miniaturized Switchless Pattern Reconfigurable Antenna Utilizing Spherical Modes Analysis, Adam Narbudowicz, Max Ammann, Nicola Marchetti

Conference Papers

The paper proposes an electrically small pattern reconfigurable antenna, which allows flexible beamforming with the antenna diameter being ?/5. The antenna has 3 ports, each designed to radiate a different spherical mode. By applying appropriate phase shift the antenna allows to flexibly sweep its bi-directional radiation pattern across a 360° azimuth, while offering 5 dBi directivity.


A Lightweight Classification Algorithm For Human Activity Recognition In Outdoor Spaces, Graham Mccalmont, Huiru Zheng, Haiying Wang, S. I. Mcclean, Matteo Zallio, Damon Berry Jan 2018

A Lightweight Classification Algorithm For Human Activity Recognition In Outdoor Spaces, Graham Mccalmont, Huiru Zheng, Haiying Wang, S. I. Mcclean, Matteo Zallio, Damon Berry

Conference Papers

The aim of this paper is to discuss the development of a lightweight classification algorithm for human activity recognition in a defined setting. Current techniques to analyse data such as machine learning are often very resource intensive meaning they can only be implemented on machines or devices that have large amounts of storage or processing power. The lightweight algorithm uses Euclidean distance to measure the difference between two points and predict the class of new records.

The results of the algorithm are largely positive achieving accuracy of 100% when classifying records taken from the same sensor position and accuracy of …


Switchless Reconfigurable Antenna With 360° Steering, Adam Narbudowicz Jan 2016

Switchless Reconfigurable Antenna With 360° Steering, Adam Narbudowicz

Conference Papers

—A novel reconfigurable antenna capable of rotating a bidirectional pattern by 360◦ in azimuth is proposed. The antenna has two ports, no aperture switching components, and offers a more compact solution than an array. It provides a reconfigurable pattern in the band 2.525–2.595 GHz and a fixed omnidirectional pattern from 2.235 to 2.725 GHz. The measured gains for four investigated configurations are between 2.1 and 3.1 dBi with total efficiencies between 80% and 89%. The antenna is intended to operate with software defined radio [digital beamforming or multiple-input–multiple-output (MIMO)], where the potential of pattern generation using the dual-port antenna can …


Digital Energy Networks: A Post Occupancy Evaluation And Appraisal Of An Intelligent Low Energy Lighting System, Anthony Colohan, Joseph Teehan, Keith Sunderland, Martin Barrett, James Preston Dec 2015

Digital Energy Networks: A Post Occupancy Evaluation And Appraisal Of An Intelligent Low Energy Lighting System, Anthony Colohan, Joseph Teehan, Keith Sunderland, Martin Barrett, James Preston

Conference Papers

The reduction in the electrical power requirements of LED lighting and the coinciding advancements in digital technology have now enabled luminaires to be powered and controlled exclusively over safety extra low voltage (SELV) wiring systems. The implementation of LED luminaires powered via a centralised 48 Volt DC low-latency communication network, with the capability to gather real-time data, has provided the potential to yield considerable electrical energy savings within a building. This paper will present an appraisal of this technology and will examine the technologies potential to make electrical energy savings, improve the quality of lighting and achieve cost savings on …


Small-Scale Wind Turbines: An Appraisal, Tony Kealy Sep 2013

Small-Scale Wind Turbines: An Appraisal, Tony Kealy

Conference Papers

This research seeks to evaluate the economic benefits to be gained by installing a small-scale wind turbine for a customer with a three-phase electrical supply requirement. The evidence for the claims made in this paper is obtained by using actual data obtained from the installed equipment over a three year period. The objective is to accurately appraise the financial investment using real data. There appears to be limited studies conducted into this type of research, possibly because the renewable energy sector is in the infancy stage in the host country, Ireland. There are some wind energy installations with financial appraisal …


Solar Photovoltaic Water Pumping For Multiple Use Systems (Mus) In Nepal, Fintan Mcloughlin, Aidan Duffy, Michael Conlon Sep 2013

Solar Photovoltaic Water Pumping For Multiple Use Systems (Mus) In Nepal, Fintan Mcloughlin, Aidan Duffy, Michael Conlon

Conference Papers

This paper investigates the performance of five solar photovoltaic (PV) Multiple Use Systems (MUS) used for water pumping. The solar MUS’s provide water for drinking, cleaning and micro-irrigation for some of the poorest communities in Nepal. In the absence of data logging, the performance of each system is investigated based on a series of rules of thumb to determine the predicted, expected and estimated demand and supply of water to small rural communities. The systems are compared based on their technical and economic performance and how this relates to local environmental, physical and socioeconomic characteristics at each location.


Design And Test Of A Linear Switched Reluctance Generator For Use In Wave-Energy Applications, Garret Brady, Cathal O'Loughlin, John Massey, David Griffiths, Carlos Villegas Oct 2012

Design And Test Of A Linear Switched Reluctance Generator For Use In Wave-Energy Applications, Garret Brady, Cathal O'Loughlin, John Massey, David Griffiths, Carlos Villegas

Conference Papers

This paper describes the design of a double-sided linear switched reluctance generator for use in wave energy applications, and the build and test of a working bench-scale prototype. Beginning with a standard shape, the development of the design, from concept to detail, is presented. Numerical simulation results – magnetic, mechanical and electrical – inform the detailed design. Construction of the generator and test rig is described. Experimental results give good agreement with simulation predictions.


A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle Jun 2012

A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle

Conference Papers

The conventional biopotential measurement configuration utilises long lead wires which connect measuring electrodes to signal conditioning circuitry. The majority of bioelectric signals that are measured from the human body have a tiny signal amplitude (5µV-5mV range) and thus any interference that is induced on the lead wires can have a detrimental effect on the original signal. In this paper, we present an alternative configuration, in which digitisation occurs on the electrode, potentially providing enhanced signal measurement as well as significant benefits in terms of the simplification of the physical interconnections between electrodes. Multiple electrodes are combined to form a digital …


Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jan 2011

Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …


Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle Jan 2011

Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx acts as the sound source, providing a quasi-periodic excitation of the vocal tract. Following a total laryngectomy, some people speak using an electrolarynx which employs an electromechanical actuator to perform the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the monotonic sound emitted, the need for a free-hand to operate the device, and the difficulty experienced by many laryngectomees in adapting to its use. One improvement to the electrolarynx, which clinicians and users frequently suggest, is the provision of a convenient hands-free control facility. This would allow more natural use of …


On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle Jan 2011

On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle

Conference Papers

Eye tracking is a well-established method of computer control for profoundly paralysed people (Anson et al., 2002). Cameras are commonly used to track eye movements (Morimoto et al., 2005) but one alternative is the bioelectrical signal known as the electrooculogram (EOG). There are some EOG mouse control systems that facilitate the use of GUI applications, but certain actions, which are straightforward using a conventional mouse, remain impossible. Unless the eyes are tracking a target, they move in saccades (jumps), making it impossible to voluntarily trace out smooth trajectories with one's gaze, as would be required to draw a smooth curve. …


Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jun 2010

Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …