Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Civil and Environmental Engineering

Technological University Dublin

Performance

Articles 1 - 5 of 5

Full-Text Articles in Engineering

Performance Modeling And Analysis Of A Thermoelectric Building Envelope For Space Heating, Xiaoli Liu, Ming Qu, Kazuaki Yazawa, Jorge Kohanoff, Piotr Chudzinski, Lorenzo Stella, Brian Norton, Niall Holmes Dr., Ruchita Jani, Hongxi Yin Jul 2022

Performance Modeling And Analysis Of A Thermoelectric Building Envelope For Space Heating, Xiaoli Liu, Ming Qu, Kazuaki Yazawa, Jorge Kohanoff, Piotr Chudzinski, Lorenzo Stella, Brian Norton, Niall Holmes Dr., Ruchita Jani, Hongxi Yin

Conference papers

To provide energy-efficient space heating and cooling, a thermoelectric building envelope (TBE) embeds thermoelectric devices in building walls. The thermoelectric device in the building envelope can provide active heating and cooling without requiring refrigerant use and energy transport among subsystems. Thus, the TBE system is energy and environmentally friendly. A few studies experimentally investigated the TBE under limited operating conditions, and only simplified models for the commercial thermoelectric module (TEM) were developed to quantify its performance. A holistic approach to optimum system performance is needed for the optimal system design and operation. The study developed a holistic TBE-building system model …


Performance And Policy Evaluation Of Solar Energy Technologies For Domestic Application In Ireland, Lacour Ayompe May 2011

Performance And Policy Evaluation Of Solar Energy Technologies For Domestic Application In Ireland, Lacour Ayompe

Doctoral

The aim of this research is to investigate the techno-economic and environmental performance of domestic scale grid-connected photovoltaic (PV) and forced circulation solar water heating (SWH) systems in Ireland; and propose a new feed-in tariff designed using a large sample of high resolution electricity demand data in order to provide credible information for informed policy formulation. Detailed field trials of experimental installations of a 1.72 kWp grid-connected PV and two SWH systems (with 4 m2 flat plate and 3 m2 heat pipe evacuated tube collectors) were undertaken to collect data. The energy, economic and environmental performances of the systems was …


Performance-Based Testing Methodology For Concrete Durability, Niall Holmes, P. A.Muhammed Basheer, Sreejith Nanukuttan, Lulu Basheer Jun 2009

Performance-Based Testing Methodology For Concrete Durability, Niall Holmes, P. A.Muhammed Basheer, Sreejith Nanukuttan, Lulu Basheer

Reports

This report presents an overview of performance based testing methodology for concrete durability and work currently underway jointly at Queens University Belfast and Heriot Watt University, Edinburgh, to undertake this research under a EPSRC funded project (EP/G02152X/1).

EN206-1 superseded BS 5328 on 1st December 2003 and allows designers and producers to use a wide range of cements and aggregate types for a variety of exposure conditions. In this new standard, the durability of concrete is specified in terms of the constituent materials of concrete, properties of fresh and hardened concrete, limitations for concrete composition, specification of concrete, delivery of …


Conductivity Sensors To Monitor Cover-Zone Performance, W. J. Mccarter, T. M. Chrisp, G. Starrs, E. Owens, Niall Holmes, L. Basheer, S. V. Nanukuttan, M. Basheer Jun 2009

Conductivity Sensors To Monitor Cover-Zone Performance, W. J. Mccarter, T. M. Chrisp, G. Starrs, E. Owens, Niall Holmes, L. Basheer, S. V. Nanukuttan, M. Basheer

Conference papers

This paper presents developments in the use of an embedded, multi-electrode conductivity sensor to study the response of the concrete cover-zone to environmental action. The sensor enables an evaluation of the temporal and spatial variation of electrical conductivity thereby allowing an integrated assessment of the cover-zone. Conductivity sensors were embedded within concrete samples to study the cover-zone response to cyclic wetting and drying under laboratory conditions. This work was extended to include the use of remote interrogation methods to study samples placed at a marine exposure site and preliminary results are presented.


Investigation Of Dynamic And Steady State Calculation Methodologies For Determination Of Building Energy Performance In The Context Of The Epbd, Mervin Dean Doyle Jul 2008

Investigation Of Dynamic And Steady State Calculation Methodologies For Determination Of Building Energy Performance In The Context Of The Epbd, Mervin Dean Doyle

Masters

The aim of this thesis was to investigate the ability of a dynamic and a quasi-steady state calculation methodology to capture the heating and cooling aspects of a buildings energy performance in the context of the requirements of the EU Energy Performance of Buildings Directive (EPBD). Chapters 1 and 2 provide a general background review and description of the implementation of the directive’s requirements in Ireland. Chapter 3 established the usefulness and relevance of building energy benchmarks, traditional approaches to building energy performance calculation methodologies. Chapter 4 established the ability of a sample of simplified and dynamic calculation tools to …