Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Engineering

Compression Testing And Failure Modes Of Steel-Concrete Composite (Sc) Structures For Nuclear Containment, Patrick Michael Wanamaker, Amit H. Varma Oct 2013

Compression Testing And Failure Modes Of Steel-Concrete Composite (Sc) Structures For Nuclear Containment, Patrick Michael Wanamaker, Amit H. Varma

The Summer Undergraduate Research Fellowship (SURF) Symposium

Although being able to provide much cleaner power than burning coal and other fossil fuels, nuclear power plants are still a tough sell to the general public due to their history of being spontaneously dangerous. The containment structures surrounding these nuclear plants, however, can play a huge role in reducing the risks associated with them. Relatively new designs for these containment assemblies, known as SC (steel-concrete composite) structures, aim to increase the strength and durability of the containment facilities while keeping costs down. By varying the spacing between shear studs, the ratio of concrete to steel, and the ratio of …


The Design Of Moment Connections Between Rectangular Hollow Sections, Billy Allen Jan 2013

The Design Of Moment Connections Between Rectangular Hollow Sections, Billy Allen

Theses

Steel portal frames in the construction industry typically comprise 1 and H sections. The design procedures for the connections in these frames (base, eaves and apex) are well established. This research is based on using rectangular hollow sections as the column and rafter members.

The eaves connection of a rectangular hollow section pitched portal frame is investigated in this report and includes a literature review of various experimental research relating to moment connections between rectangular hollow sections.

Three eaves joints were considered in this research. The joints were physically tested in the laboratory and a finite element analysis carried out. …


Structural Behaviour Of Semi-Continuous Steel End Plate Connections, Niall Scollard Jan 2013

Structural Behaviour Of Semi-Continuous Steel End Plate Connections, Niall Scollard

Theses

This report focuses on determining the joint stiffness and moment capacity values for semi-continuous (semi-rigid) connections in steel framed structures. When designing a beam to column connection, the assumption that the Joint is either fully continuous or fully pinned may not be entirely valid; it may be more realistic to classify the connection as intermediate between fully pinned and fully continuous.

The development of “the component method”, which is utilised in IS EN 1993-1-8 (EC3) to determine design values of the joint properties is described. A software solution was created using Microsoft Excel to carry out calculations in accordance with …


Kelvin Probe Electrode For Contactless Potential Measurement On Concrete-Properties And Applications, Michael Thomas Walsh Jan 2013

Kelvin Probe Electrode For Contactless Potential Measurement On Concrete-Properties And Applications, Michael Thomas Walsh

USF Tampa Graduate Theses and Dissertations

The practical feasibility of using a Kelvin Probe as a novel reference electrode in the measurement of both potential and polarization pulse response of reinforcing steel in concrete is demonstrated. Potential values measured using a KP reflect greater stability and repeatability than can typically be attained with conventional reference electrodes. Duplicate reinforced concrete beam test specimens with well-differentiated centrally corroding rebar segments were analyzed using both the Kelvin Probe (KP) and a conventional Saturated Calomel Electrode (SCE). Potential profile maps were developed using potential values recorded under static conditions with both the SCE and the KP. Nominal polarization resistance was …