Field And Numerical Study For Deteriorating Precast Double-Tee Girder Bridges, Brian Kidd
Field And Numerical Study For Deteriorating Precast Double-Tee Girder Bridges, Brian Kidd
Electronic Theses and Dissertations
Two deteriorating DT bridges in South Dakota, both over 30-years old, were field tested with a static and dynamic load. From the recorded strain values, the liveload distribution factors (LLDFs) and dynamic load allowance (IM) factors were calculated. The AASHTO LRFD and AASHTO Standard Specifications were compared with the field LLDFs and IMs. It was determined that the AASHTO LRFD Specifications were conservative for deteriorating DT girder bridges, with two exceptions. The AASHTO Standard codified LLDFs were significantly higher than the field LLDFs in all cases. The AASHTO LRFD and AASHTO Standard specifications were conservative when calculating the IM factors …