Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 11 of 11

Full-Text Articles in Engineering

Testing Of Two 10-Inch Insertion Propeller Flow Meters, Stuart Styles, Sierra Layous, Jack Evans Sep 2020

Testing Of Two 10-Inch Insertion Propeller Flow Meters, Stuart Styles, Sierra Layous, Jack Evans

BioResource and Agricultural Engineering

With funding from the US Bureau of Reclamation, California – Great Basin Region (Region 10), the Cal Poly Irrigation Training & Research Center (ITRC) conducted flow measurement accuracy testing on two 10-inch insertion (strap-on saddle) McCrometer Water Specialties propeller flow meters. Both meters were new and recently purchased by Westlands Water District. One of the meters is shown in Figure 1. Testing was performed at the ITRC Water Resources Facility (WRF) using the ITRC volumetric tank as the standard flow rate measurement for all tests. The ITRC volumetric tank was calibrated with the NIST1-traceable ITRC gravimetric tank using …


Magnetic Flow Meter Testing, Stuart Styles, Sierra Layous, Jack Evans Sep 2020

Magnetic Flow Meter Testing, Stuart Styles, Sierra Layous, Jack Evans

BioResource and Agricultural Engineering

With funding from the US Bureau of Reclamation, California – Great Basin Region (Region 10) and the California Department of Water Resources (Agreement No. 4600011908), the California Polytechnic State University, San Luis Obispo Irrigation Training & Research Center (ITRC) conducted testing on 4-inch and 10-inch spool-type magnetic flow meters ( also known as mag meters and electromagnetic flow meters) from six manufacturers (12 meters total). The testing was performed to assess the effects of various hydraulic conditions on meter accuracy.


Testing Of Two 10-Inch Insertion Magnetic Flow Meters, Stuart Styles, Sierra Layous, Jack Evans Sep 2020

Testing Of Two 10-Inch Insertion Magnetic Flow Meters, Stuart Styles, Sierra Layous, Jack Evans

BioResource and Agricultural Engineering

With funding from the US Bureau of Reclamation, California – Great Basin Region (Region 10), the Cal Poly Irrigation Training & Research Center (ITRC) conducted flow measurement accuracy testing on two 10-inch insertion (saddle-mount) McCrometer Mc Mag3000 magnetic flow meters. The meters were two of 360 new meters that were purchased by Westlands Water District. One of the meters is shown in Figure 1. Testing was performed at the ITRC Water Resources Facility (WRF) using the ITRC gravimetric (weigh) tank as the standard flow rate measurement for all tests. The ITRC gravimetric tank has a NIST1-traceable uncertainty of …


Magnetic Flow Meter Testing And The Effect Of Upstream Chemical Injection On Meter Performance, Stuart Styles, Sierra Layous, Jack Evans Aug 2020

Magnetic Flow Meter Testing And The Effect Of Upstream Chemical Injection On Meter Performance, Stuart Styles, Sierra Layous, Jack Evans

BioResource and Agricultural Engineering

With funding from the US Bureau of Reclamation, California – Great Basin Region (Region 10), the Cal Poly Irrigation Training & Research Center (ITRC) performed testing on magnetic flow meters to examine issues related to upstream chemical injection. Two sets of tests were completed:

Meter Accuracy Testing – This testing determined the flow measurement accuracy of ten (10×) meters. Previously, all the meters had been installed in irrigation pipelines immediately downstream of chemical injection and showed significant fluctuations in flow measurement readings.

Upstream Chemical Injection Testing – This testing quantified the variability of flow rate measurements at various …


Testing Of Two 30-Inch Magnetic Flow Meters, Stuart Styles, Jack Evans, Sierra Layous, Chad Tenbrink Aug 2020

Testing Of Two 30-Inch Magnetic Flow Meters, Stuart Styles, Jack Evans, Sierra Layous, Chad Tenbrink

BioResource and Agricultural Engineering

With funding from the US Bureau of Reclamation, California – Great Basin Region (Region 10), the Cal Poly Irrigation Training & Research Center (ITRC) conducted flow measurement testing on two (2×) 30inch spool-type magnetic flow meters in March of 2020. Figure 1 shows the meters installed at the testing facility. The testing determined the accuracy for each test meter in a straight pipe configuration across a range of typical water velocities (0.4 to 3.8 feet per second). Testing was performed at the ITRC Water Resources Facility (WRF) using the ITRC volumetric tank as the standard flow rate measurement for all …


Testing Of A 10 To 48-Inch Insertion Magnetic Flow Meter, Stuart Styles, Jack Evans, Sierra Layous, Chad Tenbrink Aug 2020

Testing Of A 10 To 48-Inch Insertion Magnetic Flow Meter, Stuart Styles, Jack Evans, Sierra Layous, Chad Tenbrink

BioResource and Agricultural Engineering

With funding from the US Bureau of Reclamation, California – Great Basin Region (Region 10), the Cal Poly Irrigation Training & Research Center (ITRC) conducted flow measurement testing on one (1×) 10 to 48-inch Seametrics EX21x insertion magnetic meter (“Seametrics”, “test meter”) in April 2020. Figure 1 shows the meter installed at the testing facility. The testing determined the accuracy of the test meter in a straight pipe configuration across a range of typical water velocities (0.5 to 5.8 feet per second). Testing was performed at the ITRC Water Resources Facility (WRF) using calibrated measurements from a 30-inch Krohne Enviromag …


Hydraulic Effects Of Perpendicular Water Approach Velocity On Meter Gate Flow Measurement, John M. Thorburn Aug 2020

Hydraulic Effects Of Perpendicular Water Approach Velocity On Meter Gate Flow Measurement, John M. Thorburn

Master's Theses

Accurate flow measurement is required to effectively manage water resources. California Senate Bill X7-7 (SB X7-7), legislates this need by requiring agricultural water providers serving areas greater than 25,000 acres to develop an Agricultural Water Management Plan (AWMP) and adopt pricing based at least partly on volumetric water deliveries (DWR, 2009). This study focused on two of the most common flow measurement/flow control devices used in California open channel water conveyance systems: the circular meter gate and the rectangular meter gate. Testing was conducted on three Armco-type (round gates over round discharge pipe) gates measuring 12”, 18”, and 24” and …


Overview And Uncertainty Analysis For An Irrigation Flow Measurement Facility, Kyle Feist, Zachary Markow, Stuart Styles May 2020

Overview And Uncertainty Analysis For An Irrigation Flow Measurement Facility, Kyle Feist, Zachary Markow, Stuart Styles

BioResource and Agricultural Engineering

Accurate flow measurement is critical for modern water resource management. At the irrigation district level, instantaneous flow rates must be well-measured at key bifurcation points to reliably meet downstream demand in open channel systems while also minimizing diversions. Furthermore, good flow measurement at each delivery point is a pre-requisite for successful volumetric water billing. Accuracy and repeatability are important characteristics of good flow measurement. Maximizing these traits requires periodic calibration to a common standard.

This paper presents an overview of calibration efforts and the engineering background behind an active flow measurement facility at the Irrigation Training and Research Center at …


Flow Rate Equation For Suppressed And Submerged Sluice Gates, Charles M. Burt, Albert J. Clemmens, Kyle Fesit May 2020

Flow Rate Equation For Suppressed And Submerged Sluice Gates, Charles M. Burt, Albert J. Clemmens, Kyle Fesit

BioResource and Agricultural Engineering

In irrigation projects, the control and measurement of flow rates at key bifurcation points is essential. Sluice gates at the heads of irrigation canals are used by operators to control the flow into these canals. In US irrigation districts, canal operators often estimate flow rate at the heads of canals by “experience” unless they have a flume downstream. For example, they may open a gate a certain number of turns for a change in flow rate, regardless of upstream and downstream conditions. Theoretical estimates of discharge are often inaccurate in field situations. Problems include varying and uncertain discharge coefficients, entrance …


Volumetric Flow Measurement For Irrigation District Turnouts, Charles M. Burt, Daniel J. Howes, Stuart Styles Jan 2020

Volumetric Flow Measurement For Irrigation District Turnouts, Charles M. Burt, Daniel J. Howes, Stuart Styles

BioResource and Agricultural Engineering

Technical assistance related to irrigation district turnout flow/volumetric measurement is provided by ITRC on behalf of California Dept. of Water Resources, USBR, and BIA irrigation projects. Throughout that work, it was apparent there was a need to organize well-established information as well as to provide new insights into irrigation flow measurement. The target audiences are irrigation districts and others who want to improve measurement accuracy for irrigation flow rates and volumetric deliveries to meet regulations, improve the efficiency of ditchriders (system operators), and provide equity and transparency to farmers and managers. The focus of this publication is on turnouts (deliveries) …


Discharge Coefficients For Rectangular Suppressed And Submerged Sluice Gates, Charles M. Burt, Albert J. Clemmens, Kyle Feist Jan 2020

Discharge Coefficients For Rectangular Suppressed And Submerged Sluice Gates, Charles M. Burt, Albert J. Clemmens, Kyle Feist

BioResource and Agricultural Engineering

Two sizes of sluice gates were tested in submerged conditions with a variety of flow rates and gate openings. A new equation was developed for flow rate prediction.