Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 6 of 6

Full-Text Articles in Engineering

Computational Investigation Of Biological Membranes, Allyson Karmazyn Jul 2021

Computational Investigation Of Biological Membranes, Allyson Karmazyn

Theses - ALL

Lipids are the building blocks of biological membranes, and the types of lipids that compose these cellular envelopes influence the physicochemical properties of the chemicals that can enter or exit the cell across the membrane. This work focuses on the lipid membrane compositions of eukaryotic (red blood cells) and prokaryotic (Pseudomonas aeruginosa) membranes. By analyzing the lipid-lipid and lipid-protein interactions results of the computational simulations, insights into lipid aggregation, bilayer leaflet behavior, membrane asymmetry, and small molecule transport through protein channels were obtained. The differences between prokaryotic and eukaryotic cell membranes are qualitative known; however, this work provides these concepts …


The Effects Of Solution Condition On Virus Filtration Performance, Fnu Namila Dec 2020

The Effects Of Solution Condition On Virus Filtration Performance, Fnu Namila

Graduate Theses and Dissertations

Virus filtration is an integral part of the downstream purification of mammalian cell culture-derived biotherapeutics to assure the viral safety of the products. Virus filtration membranes remove viruses based on a size-exclusion mechanism. Commercial parvovirus filers possess unique membrane structure and are designed to remove smaller non-enveloped parvoviruses with size 18-26 nm. However, some filters face issues, such as pre-mature fouling, the decline of filtrate flux, and reduction in virus retention. This doctoral dissertation focused on identifying the factors that influence the filtrate flux and the virus retention capability of commercial virus filters. The effects of solution pH and ionic …


Bioengineering Extracellular Matrix Scaffolds For Volumetric Muscle Loss, Kevin Roberts Aug 2019

Bioengineering Extracellular Matrix Scaffolds For Volumetric Muscle Loss, Kevin Roberts

Graduate Theses and Dissertations

Volumetric muscle loss overwhelms skeletal muscle’s ordinarily capable regenerative machinery, resulting in fibrosis and severe functional deficits which have defied clinical repair strategies. My work spans the design and preclinical evaluation of implants intended to drive the cell community of injured muscle toward a regenerative state, as well as the development of an understanding of the molecular responses of this cell community to biomaterial interventions. I demonstrate a new class of biomaterial by leveraging the productive capacity of sacrificial hollow fiber membrane cell culture; I show specifically that unique threads of whole extracellular matrix can be isolated by solvent degradation …


Characterization Of Fibrin Matrix Incorporated Electrospun Polycaprolactone Scaffold, Cho Yi Wong Jan 2016

Characterization Of Fibrin Matrix Incorporated Electrospun Polycaprolactone Scaffold, Cho Yi Wong

Theses and Dissertations

Specific objective: Guided tissue regeneration (GTR) aims to regenerate the lost attachment apparatus caused by periodontal disease through the use of a barrier membrane. For the GTR procedures to be successful, barrier membranes are required to be present at the surgical site for an extended period of time (weeks to months). Synthetic membranes have the advantage of prolonged presence in a wound site; however, they do not actively contribute to wound healing. Biologic membranes are recognized by the host tissue and participate in wound healing but have the disadvantage of early resorption. Therefore, the goal of this study is …


Long Term Blood Oxygenation Membranes, Joseph V. Alexander Jan 2015

Long Term Blood Oxygenation Membranes, Joseph V. Alexander

Theses and Dissertations--Biomedical Engineering

Hollow fiber membranes are widely used in blood oxygenators to remove carbon dioxide and add oxygen during cardiopulmonary bypass operations. These devices are now widely used off-label by physicians to perform extracorporeal blood oxygenation for patients with lung failure. Unfortunately, the hollow fiber membranes used in these devices fail prematurely due to blood plasma leakage and gas emboli formation.

This project formed ultrathin (~100nm) polymer coatings on polymer hollow fiber membranes. The coatings were intended to “block” existing pores on the exterior surfaces while permitting high gas fluxes. This coating is synthesized using surface imitated control radical polymerization.

The coating …


Ros-Drill Automation: Visual Feedback Control And Rotational Motion Tracking, Jhon F. Diaz Aug 2011

Ros-Drill Automation: Visual Feedback Control And Rotational Motion Tracking, Jhon F. Diaz

Master's Theses

ICSI (intra-cytoplasmic sperm injection) has attracted research interest from both biological and engineering groups. The technology is constantly evolving to perform this procedure with precision and speed. One such development is the contribution of this thesis. We focus on a relatively recent procedure called Ros-Drill© (rotationally oscillating drill), of which the early versions have already been effectively utilized for the mice. In the first part, we present a procedure to automate a critical part of the operation: initiation of the rotational oscillation, Visual feedback is used to track the pipette tip. Predetermined species-specific penetration depth is successfully utilized …