Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Engineering

Manual Material Handling Lift-Assist System For Occupational Exoskeleton, Erik Goes, Daniel Guthrie, Trevor Ward May 2022

Manual Material Handling Lift-Assist System For Occupational Exoskeleton, Erik Goes, Daniel Guthrie, Trevor Ward

Honors Capstones

It is no secret that lifting heavy objects is one of the premier causes of workplace injury, and the modern worker needs help to remain healthy. Workers need something they always have with them that makes their work safer as well as easier; our solution is an active lift-assist exoskeleton. The proposed exoskeleton design includes a military backpack exoskeleton frame, on which two actuators pull cables attached to end effectors that the operator will be holding. This system can adjust to conform to a wide variety of operator sizes, without restricting any of their range of motion. This leads to …


New Force Transducer For Mitral Valve Chordae Tendinea, Joseph Berryman May 2021

New Force Transducer For Mitral Valve Chordae Tendinea, Joseph Berryman

Biomedical Engineering Undergraduate Honors Theses

In order to inform the future of mitral valve repair and replacement, more investigation into the mechanics of the sub-valvular structure is needed. Understanding the roles of each chord during valve closure requires a sensor capable of detecting these small forces with enough sensitivity to determine the characteristics of each of the chordal types. The focus of the cantilever force transducer is to maximize this sensitivity while also minimizing the invasiveness of the sensor on the overall function of the chord. The design utilizes flexible yet strong 3D printed resin and cantilever arms to improve the strain exerted on a …


Upper Extremity Mobility Device, Timothy J. Grassi, Jacob R. Miller Jan 2020

Upper Extremity Mobility Device, Timothy J. Grassi, Jacob R. Miller

Williams Honors College, Honors Research Projects

The goal of this project was to evaluate a clinical problem, explore possible solutions, and produce a functioning prototype that would conform to all the established guidelines and requirements. The project focused on developing an upper extremity mobility device for a singular client with limited muscle activity in his arms due to childhood polio. Our design process was governed by an adapted form of the FDA Design Control Process, 21 CFR 820.30 [1]. The outcome of this project was a functioning prototype that utilized the concept of a motorized pulley system remote controlled using a key fob. This research project …


Mechanical Characterization Of Carbon Fiber And Thermoplastic Ankle Foot Orthoses, Amanda Wach Oct 2015

Mechanical Characterization Of Carbon Fiber And Thermoplastic Ankle Foot Orthoses, Amanda Wach

Master's Theses (2009 -)

The needs of an increasingly young and active orthotic patient population has led to advancements in ankle foot orthosis (AFO) design and materials to enable higher function. The Intrepid Dynamic Exoskeletal Orthosis (IDEO) is a custom energy-storing carbon fiber AFO that has demonstrated improved clinical function, allowing patients to return to high-intensity activities such as sports and military service. An improved understanding of AFO mechanical function will aid prescription and fitting, as well as assist in design modifications for different patient populations. This study investigated the mechanical properties of AFOs, specifically structural stiffness, rotational motion, and strut deflection, to discern …


Scratch Damage Evolution On Metals In Total Joint Replacements, Caleb Eljach Dec 2013

Scratch Damage Evolution On Metals In Total Joint Replacements, Caleb Eljach

All Theses

The goal of total joint replacement (TJR) is to replace nonfunctioning joint components and relieve pain, improve quality of life, and to improve joint function. Although TJR is a successful procedure, more than 54,000 knee revisions occur each year due to factors, such as wear, loosening, infection, fracture, instability, and patient related factors (Ranawat, 2010). TJRs consist of components typically composed of polyethylene and a metallic counterface (Navarro, 2008). The sliding contact that occurs between the metal and polyethylene components has been well studied and is shown to produce both surface damage and wear of the implant components (Barbour, 1997; …