Energy-resolved CT

Articles 1 - 3 of 3

Full-Text Articles in Engineering

Experimental Study Of Optimal Energy Weighting In Energy-Resolved Ct Using A Czt Detector, Franco Rupcich, Taly Gilat-Schmidt Jan 2013

Experimental Study Of Optimal Energy Weighting In Energy-Resolved Ct Using A Czt Detector, Franco Rupcich, Taly Gilat-Schmidt

Biomedical Engineering Faculty Research and Publications

Recent advances in energy-resolved CT can potentially improve contrast-to-noise ratio (CNR), which could subsequently reduce dose in conventional and dedicated breast CT. Two methods have been proposed for optimal energy weighting: weighting the energy-bin data prior to log normalization (projection-based weighting) and weighting the energy-bin data after log normalization (image-based weighting). Previous studies suggested that optimal projection-based and image-based energy weighting provide similar CNR improvements for energy-resolved CT compared to photon-counting or conventional energy-integrating CT. This study experimentally investigated the improvement in CNR of projection-based and image-based weighted images relative to photon-counting for six different energy-bin combinations using a bench …


Reducing Radiation Dose To The Female Breast During Conventional And Dedicated Breast Computed Tomography, Franco Rupcich Jan 2013

Reducing Radiation Dose To The Female Breast During Conventional And Dedicated Breast Computed Tomography, Franco Rupcich

Dissertations (1934 -)

The purpose of this study was to quantify the effectiveness of techniques intended to reduce dose to the breast during CT coronary angiography (CTCA) scans with respect to task-based image quality, and to evaluate the effectiveness of optimal energy weighting in improving contrast-to-noise ratio (CNR), and thus the potential for reducing breast dose, during energy-resolved dedicated breast CT.

A database quantifying organ dose for several radiosensitive organs irradiated during CTCA, including the breast, was generated using Monte Carlo simulations. This database facilitates estimation of organ-specific dose deposited during CTCA protocols using arbitrary x-ray spectra or tube-current modulation schemes without the …


Region-Of-Interest Material Decomposition From Truncated Energy-Resolved Ct, Taly Gilat Schmidt Oct 2011

Region-Of-Interest Material Decomposition From Truncated Energy-Resolved Ct, Taly Gilat Schmidt

Biomedical Engineering Faculty Research and Publications

Purpose: Energy-resolved CT using photon-counting detectors has the potential to provide improved material decomposition compared to dual-kVp approaches. However, available photon-counting detectors are susceptible to pulse-pileup artifacts, especially at the periphery of the field of view (FOV) where the object attenuation is low compared to the center of the FOV. Pulse pileup may be avoided by imaging a region-of-interest (ROI) where the dynamic range is expected to be limited. This work investigated performing material decomposition and reconstructing ROI basis images from truncated energy-resolved data.

Methods: A method is proposed to reconstructimages of basis functions primarily contained within the ROI, such …