Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- Bone Remodeling (2)
- Microfluidics (2)
- Accuracy (1)
- Adaptive Laboratory Evolution (1)
- Algae (1)
-
- Amputee (1)
- Anterior Cruciate Ligament (1)
- Baseball (1)
- Biomechanics (1)
- Bioprospecting (1)
- Bone (1)
- Bone Damage (1)
- Bone Loss (1)
- Canine (1)
- Cartilage (1)
- Cell Culture (1)
- Commercialization Pathway (1)
- Confocal (1)
- Custom prosthetic (1)
- Direct Current Dielectrophoresis (1)
- Electromyograph (1)
- Electrophysiology (1)
- Endothelial (1)
- FEA (1)
- Filtration (1)
- Finite Element (1)
- Finite Element Modeling (1)
- Fluorescent (1)
- Fluorescent Sphingomyelin (1)
- Fracture Risk (1)
Articles 1 - 15 of 15
Full-Text Articles in Engineering
Analysis Of Electroanatomic Mapping System Accuracy Using X-Ray Reconstruction Of Electrode Locations In A Porcine Animal Model, Hana Boudlali
Analysis Of Electroanatomic Mapping System Accuracy Using X-Ray Reconstruction Of Electrode Locations In A Porcine Animal Model, Hana Boudlali
Master's Theses
Fluoroscopy is considered the gold standard for locating catheters during cardiac electrophysiology (EP) procedures. However, fluoroscopy emits ionizing radiation which can lead to adverse health effects when exposed to in high doses (World Health Organization, 2016). Electroanatomic mapping (EAM) systems display the three-dimensional location of EP catheters and measure the local electrical activity of the heart. They can minimize a physician’s reliance on fluoroscopy and can help reduce radiation exposure during a case (Casella, 2011).
EAM systems are diagnostic medical devices that inform the placement of ablation therapy and must accurately locate catheters to be deemed safe. Test methods to …
Understanding The Effects Of Long-Duration Spaceflight On Fracture Risk In The Human Femur Using Finite Element Analysis, Keyanna Brielle Henderson
Understanding The Effects Of Long-Duration Spaceflight On Fracture Risk In The Human Femur Using Finite Element Analysis, Keyanna Brielle Henderson
Master's Theses
Long-duration spaceflight has been shown to have significant, lasting effects on the bone strength of astronauts and to contribute to age-related complications later in life. The microgravity environment of space causes a decrease in daily mechanical loading, which signals a state of disuse to bone cells. This affects the bone remodeling process, which is responsible for maintaining bone mass, causing an increase in damage and a decrease in density. This leads to bone fragility and decreases overall strength, posing a risk for fracture. However, there is little information pertaining to the timeline of bone loss and subsequent fracture risk.
This …
A Novel Method To Commercialize Medical Devices Initially Developed At California Polytechnic State University San Luis Obispo, Christina Grigorian
A Novel Method To Commercialize Medical Devices Initially Developed At California Polytechnic State University San Luis Obispo, Christina Grigorian
Master's Theses
California Polytechnic State University, San Luis Obispo is a university that encourages students to approach learning hands-on. As such, there is cutting-edge technology being developed by students in all departments on campus. Being that the university possesses an outstanding biomedical engineering department, there are groundbreaking medical devices that students are creating at Cal Poly SLO. These are devices that can better the lives of individuals suffering from ailments or fulfill needs in the medical industry. Subsequently, it is vital that these devices make it out of campus laboratories and into the hands of consumers. In order to move a product …
Finite Element Analysis Of Total Knee Arthroplasty, Sean Yueh
Finite Element Analysis Of Total Knee Arthroplasty, Sean Yueh
Master's Theses
The total knee arthroplasty (TKA) has become one of the most successful procedures in all of medicine, with an average of over 966,000 operations performed a year. Since its introduction in 1968, the TKA’s surgical process and implant designs have continuously been improved to increase survivability. However, the need for a revision TKA – due to aseptic loosening – continues to be a problematic aspect of the procedure. Stress shielding induced by different design parameters of the implant has generated controversy in the determination of an ideal configuration. The purpose of this study is to investigate how implant design parameters …
A Protocol For Achieving Adherent Cell Culture Within A Microfluidic Device, Tarra Danielle Sanders
A Protocol For Achieving Adherent Cell Culture Within A Microfluidic Device, Tarra Danielle Sanders
Master's Theses
The goal of this study is to design a protocol for the adherent cell culture within a novel microfluidic device. Microscale cell culture protocols were developed for loading cells using poly-L-lysine to enhance adherent cell culture of murine derived NIH 3T3 fibroblasts. This work sought to develop a method for adherent microculture by examining various sterilization, surface treatment, and seeding techniques. Using a vacuum suction loading technique, air plasma treatment and a poly-L-lysine surface treatment adherent cell culture was observed within the device. The work presented here is part of a collaborative effort that aims to develop protocols for the …
Effects Of Marathon Training On Male And Female Femoral Stress Fracture Risk, Clara Lin
Effects Of Marathon Training On Male And Female Femoral Stress Fracture Risk, Clara Lin
Master's Theses
Marathon runners are prone to femoral stress fractures due to the high magnitudes and frequencies of lower extremity loads during training. Female runners tend to have a greater incidence of stress fracture compared to male runners. Sex-specific differences in body structure, joint pressure, and muscle activation patterns that influence bone remodeling may cause this observed difference in stress fracture occurrence. The goal of this thesis was to develop a finite element model of the femur during marathon training, then determine if marathon training affected bone properties of male and female runners differently. To achieve this goal, a finite element femur …
Optimal Parameter Values For Accurate And Repeatable Nanoindentation Of Human Trabecular Bone, Stephen Matthew Kmak
Optimal Parameter Values For Accurate And Repeatable Nanoindentation Of Human Trabecular Bone, Stephen Matthew Kmak
Master's Theses
Nanoindentation techniques have not been standardized for use on bone tissues, making comparison of bone material properties obtained via nanoindentation across studies difficult and unreliable. This study determined a set of optimal parameter values for thermal drift correction time, dwell time, and loading rate that can be used to obtain accurate and repeatable material properties from human femoral trabecular bone through experimentation and statistical analysis. All testing was conducted using a single nanoindenter on a single trabeculae, with the assumption that material properties within the individual trabeculae were internally consistent. Parameters not of interest during this study, such as ambient …
Development And Optimization Of Imaging And Image Quantification Techniques For Tissue-Engineered Blood Vessel Mimics, Ashley Turcott
Development And Optimization Of Imaging And Image Quantification Techniques For Tissue-Engineered Blood Vessel Mimics, Ashley Turcott
Master's Theses
Blood vessels mimics (BVMs) are tissue-engineered blood vessels used to test vascular devices in an environment that mimics some simple anatomical factors of native blood vessels. It is important to accurately and consistently assess tissue-engineered blood vessels, although there is currently a lack of standardization in Cal Poly’s Tissue Engineering Lab and in the entirety of the field. The goal of this thesis was to develop and optimize imaging and image quantification techniques for tissue-engineered blood vessels.
The first aim of this thesis optimized and compared imaging and assessment techniques for electrospun scaffolds. Images from different SEMs were compared to …
Smartphone-Tape Method For Calculating Body Segment Inertial Parameters For Analysis Of Pitching Arm Kinetics, Jay Sterner
Smartphone-Tape Method For Calculating Body Segment Inertial Parameters For Analysis Of Pitching Arm Kinetics, Jay Sterner
Master's Theses
The objectives of this study were to (1) develop a non-invasive method (referred to as Smart Photo-Tape) to calculate participant-specific upper arm, forearm, and hand segment inertial properties (SIPs) (e.g. mass, center of mass, and radii of gyration) and (2) use those Smart Photo-Tape properties in inverse dynamics (ID) analyses to calculate injury-related pitching arm kinetics. Five 20- to 23- year-old baseball pitchers were photographed holding a baseball and analyzed using the Smart Photo-Tape method to obtain 3-D inertial properties for their upper arm, forearm, and hand. The upper arm and forearm segments were modelled as stacked elliptic cylinders and …
Investigation Of Experimental Variation Of Bovine Sphingomyelin As A Novel Ingredient For Ultraviolet Protection, Esther Chen
Investigation Of Experimental Variation Of Bovine Sphingomyelin As A Novel Ingredient For Ultraviolet Protection, Esther Chen
Master's Theses
Skin cancer is a prevalent disease that globally affects 2-3 million people per year [1]. This number is expected to grow tenfold as depletion of the ozone layer contributes to harsher rays reaching Earth’s surface [2]. A common way to protect against those ultraviolet waves is to apply sunscreen, however, recent reports call into question the safety of some active ingredients as they can enter through the skin into the bloodstream [3]. This thesis aims to investigate an alternative solution that uses bovine sphingomyelin (BSM) as photoprotective solution against UV irradiation.
In order to evaluate the effectiveness of BSM against …
Design Of Prototype Prosthesis For A Canine With A Right Front Limb Deformity As An Alternate Approach To Stabilize Gait And Withstand Gait Forces, Tayler R. Kastlunger
Design Of Prototype Prosthesis For A Canine With A Right Front Limb Deformity As An Alternate Approach To Stabilize Gait And Withstand Gait Forces, Tayler R. Kastlunger
Master's Theses
Congenital and developmental limb deformities in canines are rare and can occur as a genetic disorder or be caused by extrinsic factors. Without surgery to correct the deformity, conservative management can be implemented to manage exercise and restrict high-intensity activity of the canine. However, any alteration to the normal gait and locomotive biomechanics of a canine can have significant long-term effects on the musculoskeletal health and quality of life of the canine. To improve quality of life and provide an alternative and more cost-effective approach to surgery, a custom prosthetic was designed and developed for a canine born with a …
Methods To Increase Algae Biomass Productivity In Raceway Pond Monocultures, Ryan S. Anderson
Methods To Increase Algae Biomass Productivity In Raceway Pond Monocultures, Ryan S. Anderson
Master's Theses
The economics of algae biofuels and bioproducts would be improved by increased biomass productivity. Two studies on this potential are described in this thesis – one on a locally isolated filamentous yellow-green alga and the other on a planktonic strain genetically improved via selective enrichment.
Polycultures have been viewed as productive, stable, and, in some cases, harvestable by natural bioflocculation. Local native strains might have higher productivity than culture collection strains because they are already adapted to local outdoor conditions. In this study, the filamentous yellow-green alga Tribonema minus was isolated from a local volunteer polyculture. Its productivity as a …
Skier's Edge: Biomechanical Analysis, Benjamin T. Johannes
Skier's Edge: Biomechanical Analysis, Benjamin T. Johannes
Master's Theses
ABSTRACT
Skier’s Edge: Biomechanical Analysis
Benjamin T. Johannes
The Skier’s Edge trainer can be used by novice or expert skiers. Testing was performed to analyze if the use of the Skier’s Edge could reduce in shear forces of the valgus moment on the knee joint and anterior cruciate ligament (ACL) due to lesser fatigue of muscle and a higher hamstring to quadricep (H/Q) ratio activity. This leads to a reduction of improper form and an increase in balance. Experiments performed observed the change in muscle activity with the use of the Skier’s Edge over time when compared to other forms …
Subject-Specific Finite Element Models Of The Human Knee For Transtibial Amputees To Analyze Tibial Cartilage Pressure For Gait, Cycling, And Elliptical Training, Jonathon Stearns
Subject-Specific Finite Element Models Of The Human Knee For Transtibial Amputees To Analyze Tibial Cartilage Pressure For Gait, Cycling, And Elliptical Training, Jonathon Stearns
Master's Theses
It is estimated that approximately 10-12% of the adult population suffers from osteoarthritis (OA), with long reaching burdens personally and socioeconomically. OA also causes mild discomfort to severe pain in those suffering from the disease. The incidence rate of OA for individuals with transtibial amputations is much than average in the tibiofemoral joint (TF). It is well understood that abnormal articular cartilage stress, whether that be magnitude or location, increases the risk of developing OA. Finite element (FE) simulations can predict stress in the TF joint, many studies throughout the years have validated the technology used for this purpose. This …
Insulative (Direct Current) Dielectrophoretic Foul-Less Filtration In Microfuidic Systems, Matthew A A Whitman
Insulative (Direct Current) Dielectrophoretic Foul-Less Filtration In Microfuidic Systems, Matthew A A Whitman
Master's Theses
Filtration is a technology that is used almost ubiquitously in society from uses raging from filtration of macroparticles from water to pharmaceutical grade filtration products to remove anything larger than a protein. However, with such a wide range of uses, most filtration products have the same issue; membrane clogging (fouling) that prevents continuous use and requires frequent maintenance. This thesis hypothesizes that by applying a direct current (DC) to an insulating array of posts, they will create a foul-less insulative dielectrophoretic filter (iDEP) that does not clog since particles will levitate above the insulating array.
This thesis tested an inherited …