Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Engineering

Formulation And Testing Of Biodegradable Polymeric Coating On Zinc Wires In Cardiovascular Stent Application, Avishan Arab Shomali Jan 2017

Formulation And Testing Of Biodegradable Polymeric Coating On Zinc Wires In Cardiovascular Stent Application, Avishan Arab Shomali

Dissertations, Master's Theses and Master's Reports

Biodegradable and biocompatible poly (L-lactic-acid) (PLLA) coating was applied on a modified zinc (Zn) substrate by dip coating, with the intent to delay the bio-corrosion and slow the degradation rate of zinc substrate. 3-(Trimethoxysilyl) propyl methacrylate (MPS) was used for modification of the zinc substrate for promoting the adhesion between the metallic substrate and the polymer coating. It is hypothesized that the delay in Zn biodegradation could be useful in the first several weeks to prevent the early loss of mechanical integrity of the endovascular stent and to improve the healing process of the diseased vascular site. The PLLA coating …


Surface Enabled Lab-On-A-Chip (Loc) Device For Protein Detection And Separation, Zhichao Wang Jan 2017

Surface Enabled Lab-On-A-Chip (Loc) Device For Protein Detection And Separation, Zhichao Wang

Dissertations, Master's Theses and Master's Reports

Sensitive and selective chemical/biological detection/analysis for proteins is essential for applications such as disease diagnosis, species phenotype identification, product quality control, and sample examination. Lab-on-a-chip (LOC) device provides advantages of fast analysis, reduced amount of sample requirements, and low cost, to magnificently facilitate protein detection research. Isoelectric focusing (IEF) is a strong and reliable electrophoretic technique capable of discerning proteins from complex mixtures based on the isoelectric point (pI) differences. It has experienced plenty of fruitful developments during previous decades which has given it the capability of performing with highly robust and reproducible analysis. This progress has made IEF devices …


Implantable Wireless Sensor Networks: Application To Measuring Temperature For In Vivo Detection Of Infections, Praharsh Madappaly Veetil Jan 2017

Implantable Wireless Sensor Networks: Application To Measuring Temperature For In Vivo Detection Of Infections, Praharsh Madappaly Veetil

Dissertations, Master's Theses and Master's Reports

It is has been proven that infection in the body cause a local temperature increase due to localized inflammation. Therefore, a method to provide early diagnostic or long-term tracking of this infection will provide great benefits to patients with diabetic foot ulcers or sickle cell disease, and those receiving hemodialysis where they suffer from a weakened immune system. The goal of this project is to develop an implantable wireless temperature sensor based on a wireless sensor network system for monitoring infections in situ. The analog signals from the thermistors are digitized and wirelessly transmitted to a computer with an ez430-rf2500 …


A Wireless, Passive Sensor For Measuring Temperature At Orthopedic Implant Sites For Early Diagnosis Of Infections, Salil Sidharthan Karipott Jan 2017

A Wireless, Passive Sensor For Measuring Temperature At Orthopedic Implant Sites For Early Diagnosis Of Infections, Salil Sidharthan Karipott

Dissertations, Master's Theses and Master's Reports

Sensorized implants with embedded wireless, passive temperature sensors were developed for early detection of implant-associated infections. The operation principle of the sensor is based on the hypothesis that infections can lead to an increase in local temperature prior to the rise of body temperature. The sensor was an inductive capacitive (LC) circuit that has been used for monitoring of different parameters wirelessly, often in difficult to access environments. The sensor was fabricated on to an interference screw, which is used for tendon and ligament reconstruction surgeries. In this project, a sensorized interference screw was designed and fabricated by accommodating an …