Portable 6 Lead 4 Electrode Ekg, Cody Magnuson, Wes Archbold Dec 2017

Portable 6 Lead 4 Electrode Ekg, Cody Magnuson, Wes Archbold

Electrical Engineering

This project focused on designing a small, portable, 6 lead 4 electrode electrocardiogram (EKG) machine with enough accuracy and resolution to successfully diagnose clinical issues. The electrical design used to measure signals originating from the heart can be broken up into three stages. The first stage is the human device interface. Next, is the analog block that filters out common mode noise and conditions the signal for digital encoding using instrumentation amplifiers, a right leg circuit, high pass, low pass, and an amplifier. This circuit filters all frequencies above and below the frequency band of meaningful data (1-160Hz), rejects signals …


Computer-Aided Diagnoses (Cad) System: An Artificial Neural Network Approach To Mri Analysis And Diagnosis Of Alzheimer's Disease (Ad), Berizohar Padilla Cerezo Dec 2017

Computer-Aided Diagnoses (Cad) System: An Artificial Neural Network Approach To Mri Analysis And Diagnosis Of Alzheimer's Disease (Ad), Berizohar Padilla Cerezo

Master's Theses

Alzheimer’s disease (AD) is a chronic and progressive, irreversible syndrome that deteriorates the cognitive functions. Official death certificates of 2013 reported 84,767 deaths from Alzheimer’s disease, making it the 6th leading cause of death in the United States. The rate of AD is estimated to double by 2050. The neurodegeneration of AD occurs decades before symptoms of dementia are evident. Therefore, having an efficient methodology for the early and proper diagnosis can lead to more effective treatments.

Neuroimaging techniques such as magnetic resonance imaging (MRI) can detect changes in the brain of living subjects. Moreover, medical imaging techniques are the …


Skin Tone Tracking Device (Chromaband), Ziyang Bian Jun 2017

Skin Tone Tracking Device (Chromaband), Ziyang Bian

Computer Engineering

It’s long been said that your skin is a window into your health and with many illnesses the first signs of trouble actually show up in your skin. So if we have this natural warning system, then why isn’t anyone able to effectively use it to predict changes in our health? The problem is that currently there is no reliable way to accurately measure the change in skin tone and how these changes may or may not change with variations in health. This project’s aim is to design and develop a device that will record the changes in a user’s …


Poly Drop, Zachary T. Scott, Lilly J. Paul Jun 2017

Poly Drop, Zachary T. Scott, Lilly J. Paul

Computer Engineering

Poly Drop is a software interface to control an Open Drop digital micro-fluidics system. We obtained a hardware system from Gaudi labs. Our task was to create a Graphical User Interface that made the control of the device easier and more automated for better testing. We created software that had 3 parts: a control GUI, arduino code to control the hardware, and Image Analysis that gives the user information such as location and color of liquid drops as they move across the electrode grid of the Open Drop system. The GUI was developed using Java Swing. The communication between the …


Ecg Classification Using Adaptive Neuro-Fuzzy Inference System, Jason N. Rivera, Kelsey C. Rodriguez Jun 2017

Ecg Classification Using Adaptive Neuro-Fuzzy Inference System, Jason N. Rivera, Kelsey C. Rodriguez

Electrical Engineering

ECG classification using Adaptive Neuro-Fuzzy Inference System (ANFIS), sponsored by Professor Yu, involves the diagnosis of six cardiovascular conditions by analyzing one single neural network. Today’s ECG signal instrumentation does not have the ability to characterize cardiovascular diseases without a doctor’s complete evaluation and diagnosis. Our project gives a promising solution to the inability in the current market’s ECG signal instrumentation to correctly evaluate and diagnose cardiovascular diseases. ECG signal reportings is a non-invasive process that will lead to many more applications of advanced signal processing and data analysis/diagnosis of cardiovascular diseases. The inputs to the ANFIS are annotations of …


Wax Bee Gone: A Safe, Effective Solution To Ear Wax Removal, Robert G. Shenon, Shanvir S. Dhinsa Jun 2017

Wax Bee Gone: A Safe, Effective Solution To Ear Wax Removal, Robert G. Shenon, Shanvir S. Dhinsa

Electrical Engineering

This project sought to combine conventional methods such as scraping and water pressure to removal ear wax, but with electronic automation to removal the potential for human error as much as possible. Through the use of a 9V battery, and Arduino microcontroller, DC motors, and other circuitry, this project has developed a prototype for a device that can properly remove ear wax without any discomfort or risk to the user. Much of this project involved learning how to properly manipulate and provide the necessary power requirements DC motors from an Arduino and a 9V battery. Additionally, creating a 3D printed …


Hand (Motor) Movement Imagery Classification Of Eeg Using Takagi-Sugeno-Kang Fuzzy-Inference Neural Network, Rory Larson Donovan Jun 2017

Hand (Motor) Movement Imagery Classification Of Eeg Using Takagi-Sugeno-Kang Fuzzy-Inference Neural Network, Rory Larson Donovan

Master's Theses

Approximately 20 million people in the United States suffer from irreversible nerve damage and would benefit from a neuroprosthetic device modulated by a Brain-Computer Interface (BCI). These devices restore independence by replacing peripheral nervous system functions such as peripheral control. Although there are currently devices under investigation, contemporary methods fail to offer adaptability and proper signal recognition for output devices. Human anatomical differences prevent the use of a fixed model system from providing consistent classification performance among various subjects. Furthermore, notoriously noisy signals such as Electroencephalography (EEG) require complex measures for signal detection. Therefore, there remains a tremendous need to …


Silent Communication Device, Christopher Wayne Schutter Mar 2017

Silent Communication Device, Christopher Wayne Schutter

Master's Theses

Oral communication has constituted as a necessary aspect of how people interact with one another, but there are always situations where this form of communication can create distractions, irritation, or even danger. Take for example, a student in a laboratory who needs to communicate effectively with a lab partner without creating a distraction to those trying to work around said student or a soldier on a battlefield who needs to relay information effectively to his or her comrades without revealing his or her position to the enemy. It becomes apparent that people need a more exclusive form of communication in …