Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Engineering

A Rapid Prototyping Method For Constructing A Complex Three-Dimensional Substrate, Kathryn Jacoba Hart Nov 2009

A Rapid Prototyping Method For Constructing A Complex Three-Dimensional Substrate, Kathryn Jacoba Hart

Master's Theses

Cell culturing on three-dimensional structures has increased the possibilities in tissue engineering and bioreactor research. These structures enable cells to differentiate, proliferate, mobilize, and function in a conformation that more accurately mimics in vivo conditions. Computer generated models aid in development and rapid alteration of three-dimensional cell substrates, defining their internal structure as well as their external morphology. The rapid transition from substrate design to a viable culture is imperative to quickly advance research in biomedical and tissue engineering applications.

The aim of this thesis is to investigate the feasibility of a rapid prototyping process by selectively cross-linking and assembling …


Assessment Of Electrospinning As An In-House Fabrication Technique For Blood Vessel Mimic Cellular Scaffolding, Colby M. James Sep 2009

Assessment Of Electrospinning As An In-House Fabrication Technique For Blood Vessel Mimic Cellular Scaffolding, Colby M. James

Master's Theses

Intravascular devices, such as stents, must be rigorously tested before they can be approved by the FDA. This includes bench top in vitro testing to determine biocompatibility, and animal model testing to ensure safety and efficacy. As an intermediate step, a blood vessel mimic (BVM) testing method has been developed that mimics the three dimensional structure of blood vessels using a perfusion bioreactor system, human derived endothelial cells, and a biocompatible polymer scaffold used to support growth of the blood vessel cells. The focus of this thesis was to find an in-house fabrication method capable of making cellular scaffolding for …


The Effect Of Particle Surface Area To Volume Ratio On Ion Release From Cocr Spheres, Darin J. Grandfield Jun 2009

The Effect Of Particle Surface Area To Volume Ratio On Ion Release From Cocr Spheres, Darin J. Grandfield

Master's Theses

In 2005, over 200,000 Americans underwent a hip arthroplasty, the replacement of a hip joint with an artificial prosthesis. Of these arthroplasties, metal-on-metal type implants represent an increasing usage percentage. Metal-on-metal implants are selected largely for their low volumetric wear rate, durability, and resistance to corrosion. In spite of these advantages, little is known concerning the long-term consequences of heavy metal alloy use in the body, although early research indicates potentially carcinogenic results. This thesis is a preliminary investigation into these long term effects and their root causes.

An improved comprehension of the corrosion kinetics and the rate of ion …


Evaluating The Electrical Response Of Polyaniline To Mechanical Strain, Matthew L. Goebel Jun 2009

Evaluating The Electrical Response Of Polyaniline To Mechanical Strain, Matthew L. Goebel

Master's Theses

This thesis focuses on the electrical output of polyaniline films subjected to uniaxial strain in hydrochloric acid solutions. Polyaniline belongs to novel class of materials known as conducting polymers. Alternating single and double bonds in the backbone of conducting polymers allow them to transmit electric charge when they are doped with negatively charged ions. Modifying the degree of doping and other electrical/chemical treatments allow conducting polymers to exhibit conducting, semi-conducting, or insulating electrical properties. Resilient mechanical properties, good processability, and low cost make conducting polymers good candidates for applications traditionally held by metals and semi-conductors.

When tensile strain is applied …


Preparation And Characterization Of Electrospun Poly(D, L-Lactide-Co-Glycolide) Scaffolds For Vascular Tissue Engineering And The Advancement Of An In Vitro Blood Vessel Mimic, Tiffany Richelle Pena Jun 2009

Preparation And Characterization Of Electrospun Poly(D, L-Lactide-Co-Glycolide) Scaffolds For Vascular Tissue Engineering And The Advancement Of An In Vitro Blood Vessel Mimic, Tiffany Richelle Pena

Master's Theses

PREPARATION AND CHARACTERIZATION OF ELECTROSPUN POLY(D,L-LACTIDE-CO-GLYCOLIDE) SCAFFFOLDS FOR VASCULAR TISSUE ENGINEERING AND THE ADVANCEMENT OF AN IN VITRO BLOOD VESSEL MIMIC

Tiffany Richelle Peña

Currently, an estimated 1 in every 3 adult Americans are affected by one or more cardiovascular complications. The most common complication is coronary artery disease, specifically atherosclerosis. Outcomes of balloon angioplasty treatments have been significantly improved with the addition of drug eluting stents to the process. Although both bare metal and drug eluting stents have greatly increased the effectiveness of angioplasty and decreased the occurrence of restenosis, several complications still exist. For this reason, the stent …