Full-Text Articles in Engineering
Alternative Method For Low Frequency Impact Sound Measurement For Building Field Tests, Sunit Girdhar
Alternative Method For Low Frequency Impact Sound Measurement For Building Field Tests, Sunit Girdhar
Dissertations, Master's Theses and Master's Reports
What do high heels, dog nails, and dragging furniture have in common? They are all frequent sources of noise pollution and annoyance in multi-story buildings. Building codes exist to control and mitigate such noise, but these codes are outdated and fail to protect the residents against noise annoyance. Footstep noise is still the number one cause of complaints among the residents. The impact performance of floor-ceiling assemblies is characterized using a single-number rating called the Impact Sound Rating (ISR). A standard tapping machine is used in pre-defined locations on the floor and the radiated Sound Pressure Level (SPL) is measured …
Bbt Acoustic Alternative Top Bracing Cadd Data Set-Norev-2022jun28, Bill Hemphill
Bbt Acoustic Alternative Top Bracing Cadd Data Set-Norev-2022jun28, Bill Hemphill
STEM Guitar Project’s BBT Acoustic Kit
This electronic document file set consists of an overview presentation (PDF-formatted) file and companion video (MP4) and CADD files (DWG & DXF) for laser cutting the ETSU-developed alternate top bracing designs and marking templates for the STEM Guitar Project’s BBT (OM-sized) standard acoustic guitar kit. The three (3) alternative BBT top bracing designs in this release are
(a) a one-piece base for the standard kit's (Martin-style) bracing,
(b) 277 Ladder-style bracing, and
(c) an X-braced fan-style bracing similar to traditional European or so-called 'classical' acoustic guitars.
The CADD data set for each of the three (3) top bracing designs includes …
Reduced Order Modeling For Virtual Building Commissioning, Sean Rosin
Reduced Order Modeling For Virtual Building Commissioning, Sean Rosin
Boise State University Theses and Dissertations
Model order reduction can help reduce the time and monetary constraints associated with building commissioning and significantly decrease overall building energy consumption through virtual commissioning. This research aimed to determine the effectiveness of using reduced order models to simulate the overall building energy consumption, and to estimate the energy savings from control-based commissioning recommendations.
A case study building was modeled using a ‘Lumped RC’ thermal model with three thermal resistances and capacitances (3R3C) for the building interior and a 2R1C model describing the building foundation. Due to energy consumption being dependent on building systems, this model was coupled with a …