Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- Evaporative Cooling (4)
- Low Energy Cooling (4)
- Chilled Ceilings (3)
- Cooling Towers (3)
- Free Cooling (3)
-
- Chilled Beams (2)
- Displacement Ventilation (2)
- Architectural practice (1)
- Boiler heat pump conversion (1)
- Building insulation (1)
- Building performance (1)
- COP (1)
- Chilled Ceiling Panels (1)
- Circularity (1)
- Digital technologies (1)
- Dual boiler heat pump (1)
- Energy Efficiency (1)
- Energy Performance of Buildings (1)
- Energy efficiency (1)
- Heat Transfer (1)
- Low Carbon Technologies (1)
- NZEB (1)
- Online (1)
- Springboard (1)
- Thermal Effectiveness (1)
- Upskilling (1)
Articles 1 - 6 of 6
Full-Text Articles in Architecture
Addressing Low Heat Pump Heating System Sales In The Uk, Ben Costelloe
Addressing Low Heat Pump Heating System Sales In The Uk, Ben Costelloe
Articles
The replacement of existing fossil fuel boilers with heat pumps is seen as a key measure in the decarbonisation of heating systems and addressing climate change. This policy however, is currently failing in many Western European states, particularly in the UK. The many reasons for this situation are examined. However, the age of UK housing stock and particularly the high number of dwellings built prior to the introduction of building insulation regulations in 1980, are key. To maintain the running cost of air source heat pumps competitive with those of the gas boilers they generally replace the heat pump lift …
Building Performance - Societal Drive, Programme And Symposium, Joseph Little, Patrick Daly
Building Performance - Societal Drive, Programme And Symposium, Joseph Little, Patrick Daly
Articles
Society is increasingly looking at the construction industry to mitigate the environmental crisis and solve the housing crisis through wholesale embrace of three broad sets of challenges. The MSc in Building Performance (Energy Efficiency in Design) (MSc BP(EED)) was created in 2017 to provide significant upskilling in the knowledge, skills, and software applications of building design professionals so that they can meet these challenges, while creating compliant, sustainable, super-low energy, new and renovated buildings. The delivery of the programme supports upskilling of employed building design professionals at Masters level, encouraging a minority to develop their capacity and interest in research …
Heat Transfer Correlations For Low Approach Evaporative Cooling Systems In Buildings, Ben Costelloe, Donal Finn
Heat Transfer Correlations For Low Approach Evaporative Cooling Systems In Buildings, Ben Costelloe, Donal Finn
Articles
The experimental performance of an open industrial scale cooling tower, utilising small approach temperature differences (1–3 K), for rejection of heat at the low water temperatures (11–20 °C) typical of chilled ceilings and other sensible air–water heat dissipation systems in buildings, is examined. The study was carried out under temperate maritime climatic conditions (3–18 °C wet-bulb temperature range). Initially a theoretical analysis of the process at typical conditions for this climate was conducted, which indicated that a water to air (L/G) mass flow rate ratio of less than 1.0 was required for effective operation. Consequently for these low L/G ratios, …
Thermal Effectiveness Characteristics Of Low Approach Indirect Evaporative Cooling Systems In Buildings, Ben Costelloe, Donal Finn
Thermal Effectiveness Characteristics Of Low Approach Indirect Evaporative Cooling Systems In Buildings, Ben Costelloe, Donal Finn
Articles
Meteorological enthalpy analysis of temperate and maritime climates above latitude 45°N suggests that the water-side evaporative cooling technique has considerable unrealised potential with contemporary “high temperature” building cooling systems—such as chilled ceilings and displacement ventilation. As low approach conditions are the key to exploiting the cooling potential of the ambient air, thermal performance at such conditions needs to be investigated. To address the research issues, an industrial scale test rig, based on a low approach open cooling tower and plate heat exchanger and designed to maximise evaporative cooling potential, has been constructed. The thermal effectiveness of such systems (as a …
Experimental Energy Performance Of Open Cooling Towers Used Under Low And Variable Approach Conditions For Indirect Evaporative Cooling Of Buildings, Ben Costelloe, Donal Finn
Experimental Energy Performance Of Open Cooling Towers Used Under Low And Variable Approach Conditions For Indirect Evaporative Cooling Of Buildings, Ben Costelloe, Donal Finn
Articles
The success of chilled ceilings and displacement ventilation systems as a means of sensible cooling in buildings has prompted a review of evaporative cooling technology as an effective means of generating the required cooling water. When such cooling water is generated at low approach conditions (2–5 K), at the higher temperatures required in these systems (14–18°C), very high levels of availability result. In many north western European locations the levels of availability are such that the prospect of supplanting rather than simply supplementing the refrigeration system, for sensible cooling purposes, arises. The viability of the technique, however, largely depends on …
Indirect Evaporative Cooling Potential In Air-Water Systems In Temperate Climates, Ben Costelloe, Donal Finn
Indirect Evaporative Cooling Potential In Air-Water Systems In Temperate Climates, Ben Costelloe, Donal Finn
Articles
Recent developments have prompted a review of evaporative cooling technology as an effective means of cooling modern deep plan buildings. Prominent among these developments is the success of high temperature sensible cooling systems, particularly, chilled ceilings, which require a supply of cooling water at 14–18 °C. Crucial to the success of evaporative cooling technology, as a significant means of cooling in modern applications, is the ability to generate cooling water, in an indirect circuit, at a temperature which closely approaches the ambient adiabatic saturation temperature (AST) or wet bulb temperature (WBT). Recent experimental research has demonstrated that it is technically …