Open Access. Powered by Scholars. Published by Universities.®

Architecture Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 2 of 2

Full-Text Articles in Architecture

Seasonal Comparison Of Air Quality Variables And Evaluation Of Carbon Dioxide And Particulate Measurement Period In Classrooms, Daud Nosham May 2024

Seasonal Comparison Of Air Quality Variables And Evaluation Of Carbon Dioxide And Particulate Measurement Period In Classrooms, Daud Nosham

Durham School of Architectural Engineering and Construction: Dissertations, Thesis, and Student Research

Indoor air quality and thermal environmental variables were measured in 55 classrooms in the mid-western United States spanning a full academic year. The studied air quality and environmental factors included carbon dioxide, temperature, relative humidity, particle counts, air velocity, formaldehyde, total volatile organic compounds, carbon monoxide, nitrogen dioxide, and ozone.

Carbon dioxide and Particulate matter concentrations were measured for a four-day measurement period. Then one-day, two-day, and four-day occupied time average concentrations were calculated which were then compared statistically to figure out an appropriate measurement period for these air quality variables. Kruskal Wallis test and Wilcoxon test were used to …


Student Absenteeism And The Comparisons Of Two Sampling Procedures For Culturable Bioaerosol Measurement In Classrooms With And Without Upper Room Ultraviolet Germicidal Irradiation Devices, Chunxiao Su, Josephine Lau, Shawn G. Gibbs Jan 2016

Student Absenteeism And The Comparisons Of Two Sampling Procedures For Culturable Bioaerosol Measurement In Classrooms With And Without Upper Room Ultraviolet Germicidal Irradiation Devices, Chunxiao Su, Josephine Lau, Shawn G. Gibbs

Durham School of Architectural Engineering and Construction: Faculty Publications

Upper room ultraviolet germicidal irradiance (UVGI) has been shown to reduce the concentration of bioaerosols in controlled chambers. However, there is a lack of experimental results on the reduction of bioaerosol concentrations by UVGI devices in actual uncontrolled buildings. This study was carried out in an American elementary school in the Midwest. Two sampling procedures were carried out in six selected classrooms with similar dimensions that were separated into two groups: (1) UVGI exposure group and (2) non-UVGI control group. Two-stage Tisch culturable impactors were utilized to collect airborne culturable bacteria and fungi. Monthly samples were collected during unoccupied period …