Open Access. Powered by Scholars. Published by Universities.®

Architecture Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Architecture

Competence Of A Spray Passive Down-Draft Evaporative Cooling (Pdec) System For Space Cooling, Daeho Kang, Richard K. Strand Sep 2019

Competence Of A Spray Passive Down-Draft Evaporative Cooling (Pdec) System For Space Cooling, Daeho Kang, Richard K. Strand

Publications and Research

A spray PDEC system has been relatively less considered than other passive cooling strategies as one of the viable low-energy solutions in the cooling of buildings while having a great potential in energy savings. This study is intended to evaluate the capability of a spray PDEC system for space cooling. It comprises four simulation scenarios to see the system response and influence of indoor thermal environment when a spray PDEC system is adopted as a primary cooling system in two different climates. The simulation results show that a spray PDEC system causes a substantial variation in the indoor thermal environment …


Heat Transfer Correlations For Low Approach Evaporative Cooling Systems In Buildings, Ben Costelloe, Donal Finn Jan 2009

Heat Transfer Correlations For Low Approach Evaporative Cooling Systems In Buildings, Ben Costelloe, Donal Finn

Articles

The experimental performance of an open industrial scale cooling tower, utilising small approach temperature differences (1–3 K), for rejection of heat at the low water temperatures (11–20 °C) typical of chilled ceilings and other sensible air–water heat dissipation systems in buildings, is examined. The study was carried out under temperate maritime climatic conditions (3–18 °C wet-bulb temperature range). Initially a theoretical analysis of the process at typical conditions for this climate was conducted, which indicated that a water to air (L/G) mass flow rate ratio of less than 1.0 was required for effective operation. Consequently for these low L/G ratios, …


Thermal Effectiveness Characteristics Of Low Approach Indirect Evaporative Cooling Systems In Buildings, Ben Costelloe, Donal Finn Jan 2007

Thermal Effectiveness Characteristics Of Low Approach Indirect Evaporative Cooling Systems In Buildings, Ben Costelloe, Donal Finn

Articles

Meteorological enthalpy analysis of temperate and maritime climates above latitude 45°N suggests that the water-side evaporative cooling technique has considerable unrealised potential with contemporary “high temperature” building cooling systems—such as chilled ceilings and displacement ventilation. As low approach conditions are the key to exploiting the cooling potential of the ambient air, thermal performance at such conditions needs to be investigated. To address the research issues, an industrial scale test rig, based on a low approach open cooling tower and plate heat exchanger and designed to maximise evaporative cooling potential, has been constructed. The thermal effectiveness of such systems (as a …


Experimental Energy Performance Of Open Cooling Towers Used Under Low And Variable Approach Conditions For Indirect Evaporative Cooling Of Buildings, Ben Costelloe, Donal Finn Jan 2003

Experimental Energy Performance Of Open Cooling Towers Used Under Low And Variable Approach Conditions For Indirect Evaporative Cooling Of Buildings, Ben Costelloe, Donal Finn

Articles

The success of chilled ceilings and displacement ventilation systems as a means of sensible cooling in buildings has prompted a review of evaporative cooling technology as an effective means of generating the required cooling water. When such cooling water is generated at low approach conditions (2–5 K), at the higher temperatures required in these systems (14–18°C), very high levels of availability result. In many north western European locations the levels of availability are such that the prospect of supplanting rather than simply supplementing the refrigeration system, for sensible cooling purposes, arises. The viability of the technique, however, largely depends on …


Indirect Evaporative Cooling Potential In Air-Water Systems In Temperate Climates, Ben Costelloe, Donal Finn Jan 2003

Indirect Evaporative Cooling Potential In Air-Water Systems In Temperate Climates, Ben Costelloe, Donal Finn

Articles

Recent developments have prompted a review of evaporative cooling technology as an effective means of cooling modern deep plan buildings. Prominent among these developments is the success of high temperature sensible cooling systems, particularly, chilled ceilings, which require a supply of cooling water at 14–18 °C. Crucial to the success of evaporative cooling technology, as a significant means of cooling in modern applications, is the ability to generate cooling water, in an indirect circuit, at a temperature which closely approaches the ambient adiabatic saturation temperature (AST) or wet bulb temperature (WBT). Recent experimental research has demonstrated that it is technically …