Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Entire DC Network

Advances In Bone And Orthopedics 2024 Edition, Jean-Philippe Berteau, Laurent Pujo-Menjouet Jun 2024

Advances In Bone And Orthopedics 2024 Edition, Jean-Philippe Berteau, Laurent Pujo-Menjouet

Publications and Research

We are delighted to present the latest edition of ”Advances in Bone and Orthopedics,” a comprehensive compilation of pioneering research and innovative developments in the field. This volume brings together a selection of peer-reviewed abstracts from BONITOS 2024, the Fourth Season of the Bone and Orthopedics Interdisciplinary Symposium, held on May 31st, 2024, at the College of Staten Island in New York. This symposium, a hallmark event in the calendar of professionals dedicated to bone health and orthopedic excellence. The contributions within this volume reflect the breadth and depth of research presented at BONITOS 2024. These abstracts represent cutting-edge studies …


The Role Of Pennation Angle And Architectural Gearing To Rate Of Force Development In Dynamic And Isometric Muscle Contractions, Bas Van Hooren, Per Aagaard, Andrea Monte, Anthony J. Blazevich May 2024

The Role Of Pennation Angle And Architectural Gearing To Rate Of Force Development In Dynamic And Isometric Muscle Contractions, Bas Van Hooren, Per Aagaard, Andrea Monte, Anthony J. Blazevich

Research outputs 2022 to 2026

Background: Associations between muscle architecture and rate of force development (RFD) have been largely studied during fixed-end (isometric) contractions. Fixed-end contractions may, however, limit muscle shape changes and thus alter the relationship between muscle architecture an RFD. Aim: We compared the correlation between muscle architecture and architectural gearing and knee extensor RFD when assessed during dynamic versus fixed-end contractions. Methods: Twenty-two recreationally active male runners performed dynamic knee extensions at constant acceleration (2000°s−2) and isometric contractions at a fixed knee joint angle (fixed-end contractions). Torque, RFD, vastus lateralis muscle thickness, and fascicle dynamics were compared during 0–75 and 75–150 ms …


Infant Crawling Biomechanics Before, During, And After Limb Immobilization, Mark Daniel Geil Mar 2024

Infant Crawling Biomechanics Before, During, And After Limb Immobilization, Mark Daniel Geil

Datasets

Data generated from a Protokinetics Zeno Pressure Transducer processed using PKMAS4 during crawling of a single infant at four time periods: baseline, with a long leg soft cast on the left leg, 1 day following cast removal, and 2 weeks following cast removal.


Anatomic Factors Associated With Degeneration And Fraying Of The Coracoacromial Ligament, Ryan Lopez, Jaspal Singh, Mohammad Ghoraishian, Thema Nicholson, Stephen Gates, Surena Namdari Mar 2024

Anatomic Factors Associated With Degeneration And Fraying Of The Coracoacromial Ligament, Ryan Lopez, Jaspal Singh, Mohammad Ghoraishian, Thema Nicholson, Stephen Gates, Surena Namdari

Rothman Institute Faculty Papers

BACKGROUND: The coracoacromial ligament (CAL) is frequently observed to be damaged during arthroscopy and it is unclear how demographic, anatomic, and radiographic factors are related to CAL degeneration in full-thickness rotator cuff tears.

METHODS: A prospective study was conducted of patients at a single institution undergoing shoulder arthroscopy for first-time, full-thickness rotator cuff tears. We evaluated preoperative anteroposterior radiographs to obtain critical shoulder angle, glenoid inclination, acromial index, acromiohumeral distance, lateral acromial angle, and acromial morphology. We documented CAL quality, rotator cuff tear size and pattern during arthroscopy. Multiple logistic regression was used to identify predictive factors for encountering severe …


Implantation Of A Capsular Tension Ring During Cataract Surgery Attenuates Predicted Remodeling Of The Post-Surgical Lens Capsule Along The Visual Axis, Kurt A. Ameku, Caleb C. Berggren, Ryan M. Pedrigi Jan 2024

Implantation Of A Capsular Tension Ring During Cataract Surgery Attenuates Predicted Remodeling Of The Post-Surgical Lens Capsule Along The Visual Axis, Kurt A. Ameku, Caleb C. Berggren, Ryan M. Pedrigi

Department of Mechanical and Materials Engineering: Faculty Publications

Introduction: Cataract surgery permanently alters the mechanical environment of the lens capsule by placing a hole in the anterior portion and implanting an intraocular lens (IOL) that has a very different geometry from the native lens. We hypothesized that implant configuration and mechanical interactions with the post-surgical lens capsule play a key role in determining long-term fibrotic remodeling.

Methods: We developed the first finite element-growth and remodeling (FE-G&R) model of the post-surgical lens capsule to evaluate how implantation of an IOL with and without a capsular tension ring (CTR) impacted evolving lens capsule mechanics and associated fibrosis over …