Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Entire DC Network

Development And Testing Of A Low-Cost Condensation Detection System, Michael D. Montross, George A. Duncan, Richard S. Gates Jul 2006

Development And Testing Of A Low-Cost Condensation Detection System, Michael D. Montross, George A. Duncan, Richard S. Gates

Biosystems and Agricultural Engineering Faculty Publications

A condensation sensing and control system was designed to detect condensation using a commercially available leaf wetness sensor (LWS). The leaf wetness sensor was a variable resistance grid-type that responded to moisture on the surface. A circuit was developed to compare the LWS voltage output to a user specified reference voltage, and operate a relay for possible switching of a humidity control device (for example a fan and/or heater). The condensation detection system operation was validated in an environmental chamber in the laboratory using a heat exchanger and water bath. Condensate was immediately detected when the plate was cooled below …


Evaluation Of Fourier Transform Infrared Spectroscopy Measurements Of Glucose And Xylose In Biomass Hydrolyzate, Czarena L. Crofcheck, Michael D. Montross May 2006

Evaluation Of Fourier Transform Infrared Spectroscopy Measurements Of Glucose And Xylose In Biomass Hydrolyzate, Czarena L. Crofcheck, Michael D. Montross

Biosystems and Agricultural Engineering Faculty Publications

Measurement of sugars using traditional spectroscopic (UV/Vis) assays or high performance liquid chromatography (HPLC) can be time consuming and expensive. Alternative methods for measuring sugars after enzymatic hydrolysis of biomass would be convenient for screening potential biomass feedstocks and pretreatment methods. Fourier transform infrared spectroscopy (FTIR) has been utilized for measuring composition of various aqueous solutions and is evaluated here as an alternative to UV/Vis and HPLC assays. Solutions of glucose and xylose with concentrations between 0 and 1.5% w/v (total sugar content between 0 and 3.0% w/v) were used to build calibration curves for all three methods. A validation …


Vertical Loads Due To Wheat On Obstructions Located On The Floor Of A Model Bin, Marek Molenda, Michael D. Montross, Sidney A. Thompson, Jozef Horabik Jan 2006

Vertical Loads Due To Wheat On Obstructions Located On The Floor Of A Model Bin, Marek Molenda, Michael D. Montross, Sidney A. Thompson, Jozef Horabik

Biosystems and Agricultural Engineering Faculty Publications

Tests were conducted in a model grain bin to evaluate the vertical loads acting on differently shaped obstructions embedded in wheat during filling, detention, and discharge. The bin had corrugated galvanized steel walls with a 1.83 m diameter and a flat bottom. All tests were conducted in a bin that was centrically loaded and unloaded. Three differently shaped obstructions (disc, cone, and cylinder) were tested; each had a circular base equivalent to 6% of the bin floor area. The obstructions were supported in the bin using a three-legged support structure. Each leg of the support structure rested on a load …


Air Exchange Rate In A Horse Trailer During Road Transport, Joseph L. Purswell, Richard S. Gates, Laurie M. Lawrence, Jamey D. Jacob, Timothy S. Stombaugh, Robert J. Coleman Jan 2006

Air Exchange Rate In A Horse Trailer During Road Transport, Joseph L. Purswell, Richard S. Gates, Laurie M. Lawrence, Jamey D. Jacob, Timothy S. Stombaugh, Robert J. Coleman

Biosystems and Agricultural Engineering Faculty Publications

Horses traveling by road commonly experience heat stress conditions and poor air quality, which may be caused by insufficient ventilation; however, there are few estimates of air exchange in a horse trailer during transport. Air exchange rate was measured at ten locations within a four-horse trailer (internal volume 18.5 m3) using tracer gas decay measurement to assess the adequacy of ventilation. Three vehicle speeds (13, 48, and 97 km h-1) and three window configurations (all windows and roof vents closed, all windows open, all windows open and roof vents open forward) were tested with and without …