Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- Particle image velocimetry (2)
- Antennas (1)
- Atherosclerosis (1)
- Attenuation correction (1)
- Biosensors (1)
-
- Cell adhesion (1)
- Endothelial cells (1)
- FMRI (1)
- Freestanding metal nanomembrane (1)
- Gold nanoparticles (1)
- High field (1)
- Hybrid imaging (1)
- Laser interference lithography (1)
- Lung density (1)
- MRI (1)
- MRI Engineering (1)
- MRI Hardware (1)
- Magnetic Resonance Imaging (1)
- Magnetic resonance (1)
- Microfluidic chip (1)
- Microwave Electronics (1)
- Nanohole array (1)
- Nanotechnology (1)
- Neuroimaging (1)
- OMCVD (1)
- Oscillatory flow (1)
- PET/MRI (1)
- Plaque eccentricity (1)
- Plasmonics optical fiber (1)
- Proper orthogonal decomposition (1)
- Publication
- Publication Type
Articles 1 - 7 of 7
Full-Text Articles in Physics
Producing And Measuring Oscillatory Shear In A Novel Microfluidic Chip, Sanaz Lordfard, Daniel Lorusso, Tamie L. Poepping, Hristo N Nikolov, Kayla Soon, Stephen Sims, Jeffrey Dixon, David Holdsworth
Producing And Measuring Oscillatory Shear In A Novel Microfluidic Chip, Sanaz Lordfard, Daniel Lorusso, Tamie L. Poepping, Hristo N Nikolov, Kayla Soon, Stephen Sims, Jeffrey Dixon, David Holdsworth
Undergraduate Student Research Internships Conference
Purpose: To demonstrate the effectiveness of a novel microfluidic device mimicking oscillatory blood flow, allowing cell biologists to examine how endothelial cells respond to a range of oscillatory shear stress levels.
Methods: The microfluidic chip consists of a circular-shaped reservoir, leading to a rectangular channel that is examined under a microscope. The plunger is connected to a speaker system and oscilloscope, allowing the plunger to apply a range of frequencies (5-60Hz) and voltages (5-10 V, leading to a variety in oscillation amplitudes) to the reservoir region. 1.1 um fluorescent particles diluted in distilled water were used for tracking. Processing was …
Design Of Radio-Frequency Arrays For Ultra-High Field Mri, Ian R O Connell
Design Of Radio-Frequency Arrays For Ultra-High Field Mri, Ian R O Connell
Electronic Thesis and Dissertation Repository
Magnetic Resonance Imaging (MRI) is an indispensable, non-invasive diagnostic tool for the assessment of disease and function. As an investigational device, MRI has found routine use in both basic science research and medicine for both human and non-human subjects.
Due to the potential increase in spatial resolution, signal-to-noise ratio (SNR), and the ability to exploit novel tissue contrasts, the main magnetic field strength of human MRI scanners has steadily increased since inception. Beginning in the early 1980’s, 0.15 T human MRI scanners have steadily risen in main magnetic field strength with ultra-high field (UHF) 8 T MRI systems deemed to …
Advances In Image Acquisition And Filtering For Mri Neuroimaging At 7 Tesla, Andrew T. Curtis
Advances In Image Acquisition And Filtering For Mri Neuroimaging At 7 Tesla, Andrew T. Curtis
Electronic Thesis and Dissertation Repository
Performing magnetic resonance imaging at high magnetic field strength promises many improvements over low fields that are of direct benefit in functional neuroimaging. This includes the possibility of improved signal-to-noise levels, and increased BOLD functional contrast and spatial specificity. However, human MRI at 7T and above suffers from unique engineering challenges that limit the achievable gains. In this thesis, three technological developments are introduced, all of which address separate issues associated with functional magnetic resonance neuroimaging at very high magnetic field strengths.
First, the image homogeneity problem is addressed by investigating methods of RF shimming — modifying the excitation portion …
Plasmonic Optical Sensors: Performance Analysis And Engineering Towards Biosensing, Peipei Jia
Plasmonic Optical Sensors: Performance Analysis And Engineering Towards Biosensing, Peipei Jia
Electronic Thesis and Dissertation Repository
Surface plasmon resonance (SPR) sensing for quantitative analysis of chemical reactions and biological interactions has become one of the most promising applications of plasmonics. This thesis focuses on performance analysis for plasmonic sensors and implementation of plamonic optical sensors with novel nanofabrication techniques.
A universal performance analysis model is established for general two-dimensional plasmonic sensors. This model is based on the fundamental facts of surface plasmon theory. The sensitivity only depends on excitation light wavelength as well as dielectric properties of metal and dielectrics. The expression involves no structure-specified parameters, which validates this formula in broad cases of periodic, quasiperiodic …
Fabricating Cost-Effective Nanostructures For Biomedical Applications, Erden Ertorer
Fabricating Cost-Effective Nanostructures For Biomedical Applications, Erden Ertorer
Electronic Thesis and Dissertation Repository
In this thesis we described inexpensive alternatives to fabricate nanostructures on planar substrates and provided example applications to discuss the efficiency of fabricated nanostructures.
The first method we described is forming large area systematically changing multi-shape nanoscale structures on a chip by laser interference lithography. We analyzed the fabricated structures at different substrate positions with respect to exposure time, exposure angle and associated light intensity profile. We presented experimental details related to the fabrication of symmetric and biaxial periodic nanostructures on photoresist, silicon surfaces, and ion-milled glass substrates. Behavior of osteoblasts and osteoclasts on the nanostructures was investigated. These results …
Piv-Based Investigation Of Hemodynamic Factors In Diseased Carotid Artery Bifurcations With Varying Plaque Geometries, Sarah Kefayati
Piv-Based Investigation Of Hemodynamic Factors In Diseased Carotid Artery Bifurcations With Varying Plaque Geometries, Sarah Kefayati
Electronic Thesis and Dissertation Repository
Ischemic stroke is often a consequence of complications due to clot formation (i.e. thrombosis) at the site of an atherosclerotic plaque developed in the internal carotid artery. Hemodynamic factors, such as shear-stress forces and flow disturbances, can facilitate the key mechanisms of thrombosis. Atherosclerotic plaques can differ in the severity of stenosis (narrowing), in eccentricity (symmetry), as well as inclusion of ulceration (wall roughness). Therefore, in terms of clinical significance, it is important to investigate how the local hemodynamics of the carotid artery is mediated by the geometry of plaque. Knowledge of thrombosis-associated hemodynamics may provide a basis to introduce …
Mri-Based Attenuation Correction In Emission Computed Tomography, Harry R. Marshall
Mri-Based Attenuation Correction In Emission Computed Tomography, Harry R. Marshall
Electronic Thesis and Dissertation Repository
The hybridization of magnetic resonance imaging (MRI) with positron emission tomography (PET) or single photon emission computed tomography (SPECT) enables the collection of an assortment of biological data in spatial and temporal register. However, both PET and SPECT are subject to photon attenuation, a process that degrades image quality and precludes quantification. To correct for the effects of attenuation, the spatial distribution of linear attenuation coefficients (μ-coefficients) within and about the patient must be available. Unfortunately, extracting μ-coefficients from MRI is non-trivial. In this thesis, I explore the problem of MRI-based attenuation correction (AC) in emission tomography.
In particular, I …