Developing Reference Plans For Evaluating Global Clinical Trials Credentialing And Psqa Systems, Fre'etta M D Brooks, Mohammad Hussein, Jessica Lye, Christopher L Nelson, Nakamura Mitsuhiro, Mallory C Glenn, Patricia Diez, Rushil Patel, Maddison Shaw, Ileana Silvestre Patallo, Miriam Barry, Catharine H Clark, Joerg Lehmann, Stephen F Kry Jul 2025

Developing Reference Plans For Evaluating Global Clinical Trials Credentialing And Psqa Systems, Fre'etta M D Brooks, Mohammad Hussein, Jessica Lye, Christopher L Nelson, Nakamura Mitsuhiro, Mallory C Glenn, Patricia Diez, Rushil Patel, Maddison Shaw, Ileana Silvestre Patallo, Miriam Barry, Catharine H Clark, Joerg Lehmann, Stephen F Kry

Faculty, Staff and Student Publications

Purpose: To develop a practical framework for creating a diverse set of validated reference plans (varying in complexity) and implement a workflow to introduce beam modeling, calibration, and delivery errors into the reference cohort to test and compare various dosimetry audit methodologies.

Methods: Sixteen IMRT and VMAT reference plans were created, using RayStation software, for four phantom geometries based on established credentialing cases from participating Global Harmonization Group (GHG) members. These reference plans were first validated in a multi-ion-chamber phantom. Nine dosimetric errors (perturbations) were introduced into the plans by modifying beam model and/or delivery parameters (MLC-offset, MLC-transmission, leaf-tip-width, PDD, …


Hyalinization-Based Pathologic Response And Immune Infiltration Following Neoadjuvant Radiotherapy With Or Without Immune-Checkpoint Blockade In Localized Undifferentiated Pleomorphic Sarcoma, R S Traweek, M Zoghbi, R Lazcano, B M Cope, A J Bishop, A Farooqi, D Mitra, A K Yoder, B A Guadagnolo, D R Ingram, K Wani, D Shamsutdinova, A J Lazar, W-L Wang, C P Scally, E Z Keung, K E Torres, K K Hunt, R Ratan, J A Livingston, M S Nakazawa, D M Araujo, S Patel, V Ravi, A P Conley, M A Zarzour, N Somaiah, C L Roland, E F Nassif Haddad Jul 2025

Hyalinization-Based Pathologic Response And Immune Infiltration Following Neoadjuvant Radiotherapy With Or Without Immune-Checkpoint Blockade In Localized Undifferentiated Pleomorphic Sarcoma, R S Traweek, M Zoghbi, R Lazcano, B M Cope, A J Bishop, A Farooqi, D Mitra, A K Yoder, B A Guadagnolo, D R Ingram, K Wani, D Shamsutdinova, A J Lazar, W-L Wang, C P Scally, E Z Keung, K E Torres, K K Hunt, R Ratan, J A Livingston, M S Nakazawa, D M Araujo, S Patel, V Ravi, A P Conley, M A Zarzour, N Somaiah, C L Roland, E F Nassif Haddad

Faculty, Staff and Student Publications

BACKGROUND: Standard-of-care treatment of localized undifferentiated pleomorphic sarcoma (UPS) involves preoperative radiotherapy (RT) and surgery. Combination of RT with immune-checkpoint blockade (ICB) represents a promising new strategy.

METHODS: Our primary objective was to assess survival outcomes and pathologically documented response in patients receiving RT with or without ICB or chemotherapy.

RESULTS: In a retrospective cohort of 68 patients with primary or locally recurrent UPS who received neoadjuvant RT with or without ICB, the ICB group had greater tumor hyalinization than the non-ICB group (89% compared with 30%, P = 0.018). In the non-ICB group, 19/37 patients (51%) achieved hyalinization-based pathologic …


Aapm Task Group No 249b-Essentials And Guidelines For Clinical Medical Physics Residency Training Programs, Jonathon A Nye, Joseph P Dugas, William D Erwin, David P Gierga, Darryl G Kaurin, Stephanie M Leon, Ho-Ling Anthony Liu, Zheng Feng Lu, Alphonso W Magri, Lynn N Rill, Leah K Schubert, Beth A Schueler, Irina Vergalasova, John Vetter, Brian D Wichman, Amy Shu-Jung Yu, Dandan Zheng Jun 2025

Aapm Task Group No 249b-Essentials And Guidelines For Clinical Medical Physics Residency Training Programs, Jonathon A Nye, Joseph P Dugas, William D Erwin, David P Gierga, Darryl G Kaurin, Stephanie M Leon, Ho-Ling Anthony Liu, Zheng Feng Lu, Alphonso W Magri, Lynn N Rill, Leah K Schubert, Beth A Schueler, Irina Vergalasova, John Vetter, Brian D Wichman, Amy Shu-Jung Yu, Dandan Zheng

Faculty, Staff and Student Publications

The establishment of guidelines and curriculum standards for medical physics residency training is a critical component of setting expectations and competencies for the profession. Since the last publication of these standards, residency training has become integrated into the eligibility criteria for most medical physics certification bodies. The rapid growth of medical physics requires periodic review of the curriculum to remove outdated approaches, update established knowledge, and add emerging technologies. The goal of this document is to provide a reference standard for residency training program directors, training mentors, and residents to guide creation and/or optimization of their program's curriculum. The document …


Dose Prediction Via Deep Learning To Enhance Treatment Planning Of Lung Radiotherapy Including Simultaneous Integrated Boost Techniques, Wenhua Cao, Mary Gronberg, Stephen Bilton, Hana Baroudi, Skylar Gay, Christopher Peeler, Zhongxing Liao, Thomas J Whitaker, Karen Hoffman, Laurence E Court May 2025

Dose Prediction Via Deep Learning To Enhance Treatment Planning Of Lung Radiotherapy Including Simultaneous Integrated Boost Techniques, Wenhua Cao, Mary Gronberg, Stephen Bilton, Hana Baroudi, Skylar Gay, Christopher Peeler, Zhongxing Liao, Thomas J Whitaker, Karen Hoffman, Laurence E Court

Faculty, Staff and Student Publications

Background: Recent studies have shown deep learning techniques are able to predict three-dimensional (3D) dose distributions of radiotherapy treatment plans. However, their use in dose prediction for treatments with varied prescription doses including simultaneous integrated boost (SIB), that is, using multiple prescription doses within the same plan, and benefit in improving plan quality should be validated.

Purpose: To investigate the feasibility and potential benefit of using deep learning to predict dose distribution of volumetric modulated arc therapy (VMAT) including SIB techniques and improve treatment planning for patients with lung cancer.

Methods: The dose prediction model was trained with 93 retrospective …


T2-Weighted Imaging Of Rectal Cancer Using A 3d Fast Spin Echo Sequence With And Without Deep Learning Reconstruction: A Reader Study, Dan Nguyen, Sarah Palmquist, Ken-Pin Hwang, Jingfei Ma, Usama Salem, Jia Sun, Xinzeng Wang, Jong Bum Son, Randy Ernst, Peng Wei, Harmeet Kaur, Nir Stanietzky May 2025

T2-Weighted Imaging Of Rectal Cancer Using A 3d Fast Spin Echo Sequence With And Without Deep Learning Reconstruction: A Reader Study, Dan Nguyen, Sarah Palmquist, Ken-Pin Hwang, Jingfei Ma, Usama Salem, Jia Sun, Xinzeng Wang, Jong Bum Son, Randy Ernst, Peng Wei, Harmeet Kaur, Nir Stanietzky

Faculty, Staff and Student Publications

Purpose: To compare image quality and clinical utility of a T2-weighted (T2W) 3-dimensional (3D) fast spin echo (FSE) sequence using deep learning reconstruction (DLR) versus conventional reconstruction for rectal magnetic resonance imaging (MRI).

Methods: The study included 50 patients with rectal cancer who underwent rectal MRI consecutively between July 7, 2020 and January 20, 2021 using a T2W 3D FSE sequence with DLR and conventional reconstruction. Three radiologists reviewed the two sets of images, scoring overall SNR, motion artifacts, and overall image quality on a 3-point scale and indicating clinical preference for DLR or conventional reconstruction based on those three …


Robust Automated Method Of Spatial Resolution Measurement In Radiotherapy Ct Simulation Images, Pavel Govyadinov, Rick R Layman, Tucker Netherton, Raymond Mumme, Aaron K Jones, Laurence E Court, Moiz Ahmad Mar 2025

Robust Automated Method Of Spatial Resolution Measurement In Radiotherapy Ct Simulation Images, Pavel Govyadinov, Rick R Layman, Tucker Netherton, Raymond Mumme, Aaron K Jones, Laurence E Court, Moiz Ahmad

Faculty, Staff and Student Publications

Background: Variation in imaging protocol, patient positioning, and the presence of artifacts can vary image quality in CT images used for radiotherapy planning. Automated methods for spatial resolution (SR) estimation exist but require further investigation and validation for wider adoption.

Purpose: To validated previously existing algorithm for SR estimation and introduce improvements that make it robust to patient positioning, CT protocol, site, and artifacts.

Method: A reference algorithm based on the previous gold standard was recreated and modified to improve robustness. The algorithms were tested on three different datasets: (1) a cylindrical ACR CT QC phantom scanned using a Siemens …


American Association Of Physicists In Medicine (Aapm) Chapter Climate Check: Mixed Methods Analysis Of Survey Responses, Ashley J Cetnar, Ghada Aldosary, Meghan C Koo, Holly Lincoln, Angélica Pérez-Andújar, Surendra Prajapati, Samantha J Simiele, Kristi R G Hendrickson Mar 2025

American Association Of Physicists In Medicine (Aapm) Chapter Climate Check: Mixed Methods Analysis Of Survey Responses, Ashley J Cetnar, Ghada Aldosary, Meghan C Koo, Holly Lincoln, Angélica Pérez-Andújar, Surendra Prajapati, Samantha J Simiele, Kristi R G Hendrickson

Faculty, Staff and Student Publications

Introduction: The American Association of Physicists in Medicine (AAPM) recently shared results and recommendations from its first Equity, Diversity, and Inclusion (EDI) Climate Survey, which was designed to assess the climate at the workplace, the AAPM organization, and the AAPM regional chapter level. This work further explores the status of EDI at the regional chapter level.

Methods: AAPM's EDI Survey was distributed to 5500 members and had a response rate of 25%. In the survey, three open-ended comment boxes were provided for feedback, including one for regional AAPM members. Sixty-four percent of respondents indicated they were part of a regional …


Clinical Use Of Gafchromic Ebt4 Film For In Vivo Dosimetry For Total Body Irradiation, Emily Draeger, Fada Guan, Min-Young Lee, Dae Yup Han, William Donahue, Zhe Jay Chen Mar 2025

Clinical Use Of Gafchromic Ebt4 Film For In Vivo Dosimetry For Total Body Irradiation, Emily Draeger, Fada Guan, Min-Young Lee, Dae Yup Han, William Donahue, Zhe Jay Chen

Faculty, Staff and Student Publications

Purpose: In vivo dosimetry is a common requirement to validate dose accuracy/uniformity in total body irradiation (TBI). Several detectors can be used for in vivo dosimetry, including thermoluminescent dosimeters (TLDs), diodes, ion chambers, optically stimulated luminescent dosimeters (OSLDs), and film. TLDs are well established for use in vivo but required expertise and clinical system availability may make them impractical for multifractionated TBI. OSLDs offer quick readout, but recalls have restricted their use. The purpose of this work was to validate the newly available Gafchromic EBT4 film for TBI in vivo dosimetry.

Methods: Film calibration curves were created under standard conditions …


An Automated Treatment Planning Portfolio For Whole Breast Radiotherapy, Hana Baroudi, Leonard Che Fru, Deborah Schofield, Dominique L Roniger, Callistus Nguyen, Donald Hancock, Christine Chung, Beth M Beadle, Kent A Gifford, Tucker Netherton, Joshua S Niedzielski, Adam Melancon, Manickam Muruganandham, Meena Khan, Simona F Shaitelman, Sanjay Shete, Patricia Murina, Daniel Venencia, Sheeba Thengumpallil, Conny Vrieling, Joy Zhang, Melissa P Mitchell, Laurence E Court Mar 2025

An Automated Treatment Planning Portfolio For Whole Breast Radiotherapy, Hana Baroudi, Leonard Che Fru, Deborah Schofield, Dominique L Roniger, Callistus Nguyen, Donald Hancock, Christine Chung, Beth M Beadle, Kent A Gifford, Tucker Netherton, Joshua S Niedzielski, Adam Melancon, Manickam Muruganandham, Meena Khan, Simona F Shaitelman, Sanjay Shete, Patricia Murina, Daniel Venencia, Sheeba Thengumpallil, Conny Vrieling, Joy Zhang, Melissa P Mitchell, Laurence E Court

Faculty, Staff and Student Publications

Background: Automation in radiotherapy presents a promising solution to the increasing cancer burden and workforce shortages. However, existing automated methods for breast radiotherapy lack a comprehensive, end-to-end solution that meets varying standards of care.

Purpose: This study aims to develop a complete portfolio of automated radiotherapy treatment planning for intact breasts, tailored to individual patient factors, clinical approaches, and available resources.

Methods: We developed five automated conventional treatment approaches and utilized an established RapidPlan model for volumetric arc therapy. These approaches include conventional tangents for whole breast treatment, two variants for supraclavicular nodes (SCLV) treatment with/without axillary nodes, and two …


Iroc Phantoms Accurately Detect Mlc Delivery Errors, Sharbacha S Edward, Julianne M Pollard-Larkin, Peter A Balter, Rebecca M Howell, Christine B Peterson, Stephen F Kry Feb 2025

Iroc Phantoms Accurately Detect Mlc Delivery Errors, Sharbacha S Edward, Julianne M Pollard-Larkin, Peter A Balter, Rebecca M Howell, Christine B Peterson, Stephen F Kry

Faculty, Staff and Student Publications

Purpose: We evaluated the impact of random and whole-bank multileaf collimator (MLC) delivery errors on dosimetric delivery accuracy in the Imaging and Radiation Oncology Core (IROC) phantom audits, as well as differences in delivery accuracy between the IROC phantom prescription and typical clinical fraction sizes.

Methods and materials: Plans were created for the IROC IMRT head and neck (H&N) and SBRT spine phantoms. MLC leaf errors were introduced into the plans: random shifts between -2 and 2 mm, and whole bank shifts of 0.5, 1, and 2 mm. Plans were recalculated and delivered on a Varian Truebeam, and the log …


Rapidbrachyivbt: A Dosimetry Software For Patient-Specific Intravascular Brachytherapy Dose Calculations On Optical Coherence Tomography Images, Maryam Rahbaran, Jonathan Kalinowski, Joseph M Decunha, Kevin J Croce, Brian A Bergmark, James M G Tsui, Phillip M Devlin, Shirin A Enger Feb 2025

Rapidbrachyivbt: A Dosimetry Software For Patient-Specific Intravascular Brachytherapy Dose Calculations On Optical Coherence Tomography Images, Maryam Rahbaran, Jonathan Kalinowski, Joseph M Decunha, Kevin J Croce, Brian A Bergmark, James M G Tsui, Phillip M Devlin, Shirin A Enger

Faculty, Staff and Student Publications

Background: Coronary artery disease is the most common form of cardiovascular disease. It is caused by excess plaque along the arterial wall, blocking blood flow to the heart (stenosis). A percutaneous coronary intervention widens the arterial wall with the inflation of a balloon inside the lesion area and leaves behind a metal stent to prevent re-narrowing of the artery (restenosis). However, in-stent restenosis may occur due to damage to the arterial wall tissue, triggering neointimal hyperplasia, producing fibrotic and calcified plaques and narrowing the artery again. Drug-eluting stents, which slowly release medication to inhibit neointimal hyperplasia, are used to prevent …


On The Acceptance, Commissioning, And Quality Assurance Of Electron Flash Units, Allison Palmiero, Kevin Liu, Julie Colnot, Nitish Chopra, Denae Neill, Luke Connell, Brett Velasquez, Albert C Koong, Steven H Lin, Peter Balter, Ramesh Tailor, Charlotte Robert, Jean-François Germond, Patrik Gonçalves Jorge, Reiner Geyer, Sam Beddar, Raphael Moeckli, Emil Schüler Feb 2025

On The Acceptance, Commissioning, And Quality Assurance Of Electron Flash Units, Allison Palmiero, Kevin Liu, Julie Colnot, Nitish Chopra, Denae Neill, Luke Connell, Brett Velasquez, Albert C Koong, Steven H Lin, Peter Balter, Ramesh Tailor, Charlotte Robert, Jean-François Germond, Patrik Gonçalves Jorge, Reiner Geyer, Sam Beddar, Raphael Moeckli, Emil Schüler

Faculty, Staff and Student Publications

Background and purpose: FLASH or ultra-high dose rate (UHDR) radiation therapy (RT) has gained attention in recent years for its ability to spare normal tissues relative to conventional dose rate (CDR) RT in various preclinical trials. However, clinical implementation of this promising treatment option has been limited because of the lack of availability of accelerators capable of delivering UHDR RT. Commercial options are finally reaching the market that produce electron beams with average dose rates of up to 1000 Gy/s. We established a framework for the acceptance, commissioning, and periodic quality assurance (QA) of electron FLASH units and present an …


Open-Chest Cardiac Ultrasound-Mediated Imaging With A Vacuum Coupler, Nilesh Mathuria, Krithik Vishwanath, Giorgio Brero, Blake C Fallon, Antonio Martino, Richard C Willson, Carly S Filgueira, Richard R Bouchard Feb 2025

Open-Chest Cardiac Ultrasound-Mediated Imaging With A Vacuum Coupler, Nilesh Mathuria, Krithik Vishwanath, Giorgio Brero, Blake C Fallon, Antonio Martino, Richard C Willson, Carly S Filgueira, Richard R Bouchard

Faculty, Staff and Student Publications

BACKGROUND: A fundamental obstacle for the preclinical development of ultrasound-(US) mediated cardiac imaging remains cardiac motion, which limits interframe correlation during extended acquisition periods.

PURPOSE: To address this need, we present the design and implementation of a 3D-printed vacuum coupler that stabilizes a US transducer on the epicardial surface of the heart for feasibility assessment and development of advanced, cardiac, US-mediated imaging approaches.

METHODS: The vacuum coupler was 3D printed with biocompatible resins and secured with a standard intraoperative suction aspirator. US-mediated imaging (i.e., B-mode and photoacoustic [PA] imaging) was performed in an open-chest porcine model with and without the …


Imaging Lung Tumor Motion Using Integrated-Mode Proton Radiography-A Phantom Study Towards Tumor Tracking In Proton Radiotherapy, Ryan Fullarton, Mikaël Simard, Lennart Volz, Allison Toltz, Savanna Chung, Christoph Schuy, Daniel G Robertson, Gary Royle, Sam Beddar, Colin Baker, Christian Graeff, Charles-Antoine Collins-Fekete Feb 2025

Imaging Lung Tumor Motion Using Integrated-Mode Proton Radiography-A Phantom Study Towards Tumor Tracking In Proton Radiotherapy, Ryan Fullarton, Mikaël Simard, Lennart Volz, Allison Toltz, Savanna Chung, Christoph Schuy, Daniel G Robertson, Gary Royle, Sam Beddar, Colin Baker, Christian Graeff, Charles-Antoine Collins-Fekete

Faculty, Staff and Student Publications

BACKGROUND: Motion of lung tumors during radiotherapy leads to decreased accuracy of the delivered dose distribution. This is especially true for proton radiotherapy due to the finite range of the proton beam. Methods for mitigating motion rely on knowing the position of the tumor during treatment.

PURPOSE: Proton radiography uses the treatment beam, at an energy high enough to traverse the patient, to produce a radiograph. This work shows the first results of using an integrated-mode proton radiography system to track the position of moving objects in an experimental phantom study; demonstrating the potential of using this method for measuring …


A Multiple X-Ray-Source Array (Mxa) System With A Planar Two-Dimensional Source Distribution For Digital Breast Tomosynthesis, Alejandro Sisniega, Andrew M Hernandez, Shadi A Shakeri, Elizabeth A Morris, John M Boone, Jeffrey H Siewerdsen, Paul R Schwoebel Dec 2024

A Multiple X-Ray-Source Array (Mxa) System With A Planar Two-Dimensional Source Distribution For Digital Breast Tomosynthesis, Alejandro Sisniega, Andrew M Hernandez, Shadi A Shakeri, Elizabeth A Morris, John M Boone, Jeffrey H Siewerdsen, Paul R Schwoebel

Faculty, Staff and Student Publications

Background: Digital breast tomosynthesis (DBT) has outpaced digital mammography in clinical adoption in the United States; however, substantial technological limitations remain to image quality in DBT, including undersampling from a one-dimensional (1D) scan geometry, x-ray source motion during acquisition, and patient motion artifacts from long exam times.

Purpose: A thermionic cathode x-ray system employing two-dimensional (2D, planar) multiple x-ray-source arrays (MXA) is proposed to improve DBT image quality.

Methods: A 1D MXA, consisting of a linear array of thermionic cathodes was used to simulate a 2D MXA. The 1D MXA included 11 focal spots separated by a distance of Δd …


Promotion And Tenure For Medical Physicists Should Be Based On Article Specific Measures And Not On Journal Impact Factor, Samantha Hedrick, Jinzhong Yang, Yi Rong Dec 2024

Promotion And Tenure For Medical Physicists Should Be Based On Article Specific Measures And Not On Journal Impact Factor, Samantha Hedrick, Jinzhong Yang, Yi Rong

Faculty, Staff and Student Publications

No abstract provided.


Interpreting The Biological Effects Of Protons As A Function Of Physical Quantity: Linear Energy Transfer Or Microdosimetric Lineal Energy Spectrum?, Fada Guan, Lawrence Bronk, Matthew Kerr, Yuting Li, Leslie A Braby, Mary Sobieski, Xiaochun Wang, Xiaodong Zhang, Clifford Stephan, David R Grosshans, Radhe Mohan Oct 2024

Interpreting The Biological Effects Of Protons As A Function Of Physical Quantity: Linear Energy Transfer Or Microdosimetric Lineal Energy Spectrum?, Fada Guan, Lawrence Bronk, Matthew Kerr, Yuting Li, Leslie A Braby, Mary Sobieski, Xiaochun Wang, Xiaodong Zhang, Clifford Stephan, David R Grosshans, Radhe Mohan

Faculty, Staff and Student Publications

The choice of appropriate physical quantities to characterize the biological effects of ionizing radiation has evolved over time coupled with advances in scientific understanding. The basic hypothesis in radiation dosimetry is that the energy deposited by ionizing radiation initiates all the consequences of exposure in a biological sample (e.g., DNA damage, reproductive cell death). Physical quantities defined to characterize energy deposition have included dose, a measure of the mean energy imparted per unit mass of the target, and linear energy transfer (LET), a measure of the mean energy deposition per unit distance that charged particles traverse in a medium. The …


Nanoscale Gold Nanoparticle (Gnp)-Laden Tumor Cell Model And Its Use For Estimation Of Intracellular Dose From Gnp-Induced Secondary Electrons, Sandun Jayarathna, Amrit Kaphle, Sunil Krishnan, Sang Hyun Cho Sep 2024

Nanoscale Gold Nanoparticle (Gnp)-Laden Tumor Cell Model And Its Use For Estimation Of Intracellular Dose From Gnp-Induced Secondary Electrons, Sandun Jayarathna, Amrit Kaphle, Sunil Krishnan, Sang Hyun Cho

Faculty, Staff and Student Publications

Background: Gold nanoparticles (GNPs) accumulated within tumor cells have been shown to sensitize tumors to radiotherapy. From a physics point of view, the observed GNP-mediated radiosensitization is due to various downstream effects of the secondary electron (SE) production from internalized GNPs such as GNP-mediated dose enhancement. Over the years, numerous computational investigations on GNP-mediated dose enhancement/radiosensitization have been conducted. However, such investigations have relied mostly on simple cellular geometry models and/or artificial GNP distributions. Thus, it is at least desirable, if not necessary, to conduct further investigations using cellular geometry models that properly reflect realistic cell morphology as well as …


Quantitative Evaluation Of 90y-Pet/Ct And 90y-Spect/Ct-Based Dosimetry Following Yttrium-90 Radioembolization, Srinivas Cheenu Kappadath, Eric Courtney Henry, Benjamin P Lopez, Armeen Mahvash Sep 2024

Quantitative Evaluation Of 90y-Pet/Ct And 90y-Spect/Ct-Based Dosimetry Following Yttrium-90 Radioembolization, Srinivas Cheenu Kappadath, Eric Courtney Henry, Benjamin P Lopez, Armeen Mahvash

Faculty, Staff and Student Publications

Background: Following yttrium-90 radioembolization (90Y-RE), 90Y-PET/CT and 90Y-SPECT/CT imaging provide the means to calculate the voxelized absorbed dose distribution. Given the widespread use of the two imaging modalities and lack of well-established standardized dosimetry protocols for 90Y-RE, there is a clinical need to systematically investigate and evaluate differences in the performance of voxel-based dosimetry between 90Y-PET/CT and 90Y-SPECT/CT.

Purpose: To quantitatively analyze and compare 90Y-PET/CT and 90Y-SPECT/CT-based dosimetry following 90Y-RE.

Methods: 90Y-PET/CT and 90Y-SPECT/CT imaging was acquired for 35 patients following 90Y-RE with TheraSphere for the treatment of unresectable hepatocellular carcinoma. Dosimetry was performed using the local deposition method with …


Landmark-Based Auto-Contouring Of Clinical Target Volumes For Radiotherapy Of Nasopharyngeal Cancer, Carlos Sjogreen, Tucker J Netherton, Anna Lee, Moaaz Soliman, Skylar S Gay, Callistus Nguyen, Raymond Mumme, Ivan Vazquez, Dong Joo Rhee, Carlos E Cardenas, Mary K Martel, Beth M Beadle, Laurence Edward Court Sep 2024

Landmark-Based Auto-Contouring Of Clinical Target Volumes For Radiotherapy Of Nasopharyngeal Cancer, Carlos Sjogreen, Tucker J Netherton, Anna Lee, Moaaz Soliman, Skylar S Gay, Callistus Nguyen, Raymond Mumme, Ivan Vazquez, Dong Joo Rhee, Carlos E Cardenas, Mary K Martel, Beth M Beadle, Laurence Edward Court

Faculty, Staff and Student Publications

Background: The delineation of clinical target volumes (CTVs) for radiotherapy for nasopharyngeal cancer is complex and varies based on the location and extent of disease.

Purpose: The current study aimed to develop an auto-contouring solution following one protocol guidelines (NRG-HN001) that can be adjusted to meet other guidelines, such as RTOG-0225 and the 2018 International guidelines.

Methods: The study used 2-channel 3-dimensional U-Net and nnU-Net framework to auto-contour 27 normal structures in the head and neck (H&N) region that are used to define CTVs in the protocol. To define the CTV-Expansion (CTV1 and CTV2) and CTV-Overall (the outer envelope of …


Evaluating The Relationship Between Magnetic Resonance Image Quality Metrics And Deep Learning-Based Segmentation Accuracy Of Brain Tumors, Rajarajeswari Muthusivarajan, Adrian Celaya, Joshua P Yung, James P Long, Satish E Viswanath, Daniel S Marcus, Caroline Chung, David Fuentes Jul 2024

Evaluating The Relationship Between Magnetic Resonance Image Quality Metrics And Deep Learning-Based Segmentation Accuracy Of Brain Tumors, Rajarajeswari Muthusivarajan, Adrian Celaya, Joshua P Yung, James P Long, Satish E Viswanath, Daniel S Marcus, Caroline Chung, David Fuentes

Faculty, Staff and Student Publications

Background: Magnetic resonance imaging (MRI) scans are known to suffer from a variety of acquisition artifacts as well as equipment-based variations that impact image appearance and segmentation performance. It is still unclear whether a direct relationship exists between magnetic resonance (MR) image quality metrics (IQMs) (e.g., signal-to-noise, contrast-to-noise) and segmentation accuracy.

Purpose: Deep learning (DL) approaches have shown significant promise for automated segmentation of brain tumors on MRI but depend on the quality of input training images. We sought to evaluate the relationship between IQMs of input training images and DL-based brain tumor segmentation accuracy toward developing more generalizable models …


Evaluating Automatically Generated Normal Tissue Contours For Safe Use In Head And Neck And Cervical Cancer Treatment Planning, Raphael Douglas, Adenike Olanrewaju, Raymond Mumme, Lifei Zhang, Beth M Beadle, Laurence Edward Court Jul 2024

Evaluating Automatically Generated Normal Tissue Contours For Safe Use In Head And Neck And Cervical Cancer Treatment Planning, Raphael Douglas, Adenike Olanrewaju, Raymond Mumme, Lifei Zhang, Beth M Beadle, Laurence Edward Court

Faculty, Staff and Student Publications

Purpose: Volumetric-modulated arc therapy (VMAT) is a widely accepted treatment method for head and neck (HN) and cervical cancers; however, creating contours and plan optimization for VMAT plans is a time-consuming process. Our group has created an automated treatment planning tool, the Radiation Planning Assistant (RPA), that uses deep learning models to generate organs at risk (OARs), planning structures and automates plan optimization. This study quantitatively evaluates the quality of contours generated by the RPA tool.

Methods: For patients with HN (54) and cervical (39) cancers, we retrospectively generated autoplans using the RPA. Autoplans were generated using deep-learning and RapidPlan …


Thyroid Cartilage Metastases From Prostate Cancer On 18f Psma Pet Ct: A Case Series, Poonamjeet Loyal, Samuel Gitau, Khalid Makhdomi Jun 2024

Thyroid Cartilage Metastases From Prostate Cancer On 18f Psma Pet Ct: A Case Series, Poonamjeet Loyal, Samuel Gitau, Khalid Makhdomi

Imaging & Diagnostic Radiology, East Africa

Prostate cancer metastases to the thyroid cartilage is an extremely rare phenomenon. We report three cases of advanced prostate carcinoma with metastases to the thyroid cartilage identified on 18F prostate-specific membrane antigen-1007 (PSMA-1007) positron emission tomography (PET)/computed tomography (CT). The pathophysiology and possibility for under-reporting are also discussed. Prostate cancer metastases to the larynx should be considered in the differential diagnosis of thyroid cartilage lesions in patients with advanced prostate cancer and is associated with poor prognosis.


A Radiotherapy Community Data-Driven Approach To Determine Which Complexity Metrics Best Predict The Impact Of Atypical Tps Beam Modeling On Clinical Dose Calculation Accuracy, Fre'etta Mae Dayo Brooks, Mallory Carson Glenn, Victor Hernandez, Jordi Saez, Hunter Mehrens, Julianne Marie Pollard-Larkin, Rebecca Maureen Howell, Christine Burns Peterson, Christopher Lee Nelson, Catharine Helen Clark, Stephen Frasier Kry May 2024

A Radiotherapy Community Data-Driven Approach To Determine Which Complexity Metrics Best Predict The Impact Of Atypical Tps Beam Modeling On Clinical Dose Calculation Accuracy, Fre'etta Mae Dayo Brooks, Mallory Carson Glenn, Victor Hernandez, Jordi Saez, Hunter Mehrens, Julianne Marie Pollard-Larkin, Rebecca Maureen Howell, Christine Burns Peterson, Christopher Lee Nelson, Catharine Helen Clark, Stephen Frasier Kry

Faculty, Staff and Student Publications

PURPOSE: To quantify the impact of treatment planning system beam model parameters, based on the actual spread in radiotherapy community data, on clinical treatment plans and determine which complexity metrics best describe the impact beam modeling errors have on dose accuracy.

METHODS: Ten beam modeling parameters for a Varian accelerator were modified in RayStation to match radiotherapy community data at the 2.5, 25, 50, 75, and 97.5 percentile levels. These modifications were evaluated on 25 patient cases, including prostate, non-small cell lung, H&N, brain, and mesothelioma, generating 1,000 plan perturbations. Differences in the mean planned dose to clinical target volumes …


Optimized Scoring Of End-To-End Dosimetry Audits For Passive Motion Management – A Simulation Study Using The Iroc Thorax Phantom, Alex Burton, Mathieu Gaudreault, Nicholas Hardcastle, Jessica Lye, Sabeena Beveridge, Stephen F Kry, Rick Franich May 2024

Optimized Scoring Of End-To-End Dosimetry Audits For Passive Motion Management – A Simulation Study Using The Iroc Thorax Phantom, Alex Burton, Mathieu Gaudreault, Nicholas Hardcastle, Jessica Lye, Sabeena Beveridge, Stephen F Kry, Rick Franich

Faculty, Staff and Student Publications

Dosimetry audits for passive motion management require dynamically-acquired measurements in a moving phantom to be compared to statically calculated planned doses. This study aimed to characterise the relationship between planning and delivery errors, and the measured dose in the Imaging and Radiation Oncology Core (IROC) thorax phantom, to assess different audit scoring approaches. Treatment plans were created using a 4DCT scan of the IROC phantom, equipped with film and thermoluminescent dosimeters (TLDs). Plans were created on the average intensity projection from all bins. Three levels of aperture complexity were explored: dynamic conformal arcs (DCAT), low-, and high-complexity volumetric modulated arcs …


Automatic End-To-End Vmat Treatment Planning For Rectal Cancers, Kai Huang, Christine Chung, Ethan B Ludmir, Lifei Zhang, Constance A Owens, Jean Gumma-De La Vega, Jack Duryea, Yao Zhao, Xinru Chen, David Fuentes, Carlos E Cardenas, Tina Marie Briere, Sam Beddar, Laurence E Court, Prajnan Das Apr 2024

Automatic End-To-End Vmat Treatment Planning For Rectal Cancers, Kai Huang, Christine Chung, Ethan B Ludmir, Lifei Zhang, Constance A Owens, Jean Gumma-De La Vega, Jack Duryea, Yao Zhao, Xinru Chen, David Fuentes, Carlos E Cardenas, Tina Marie Briere, Sam Beddar, Laurence E Court, Prajnan Das

Faculty, Staff and Student Publications

BACKGROUND: The treatment planning process from segmentation to producing a deliverable plan is time-consuming and labor-intensive. Existing solutions automate the segmentation and planning processes individually. The feasibility of combining auto-segmentation and auto-planning for volumetric modulated arc therapy (VMAT) for rectal cancers in an end-to-end process is not clear.

PURPOSE: To create and clinically evaluate a complete end-to-end process for auto-segmentation and auto-planning of VMAT for rectal cancer requiring only the gross tumor volume contour and a CT scan as inputs.

METHODS: Patient scans and data were retrospectively selected from our institutional records for patients treated for malignant neoplasm of the …


The Value Of Global Collaborations, Chris Trauernicht, Laurence Court Apr 2024

The Value Of Global Collaborations, Chris Trauernicht, Laurence Court

Faculty, Staff and Student Publications

No abstract provided.


Correcting Ct Misregistration In Data-Driven Gated (Ddg) Pet With Pet Self-Gating And Deformable Image Registration, Peng Sun, M Allan Thomas, Dershan Luo, Tinsu Pan Mar 2024

Correcting Ct Misregistration In Data-Driven Gated (Ddg) Pet With Pet Self-Gating And Deformable Image Registration, Peng Sun, M Allan Thomas, Dershan Luo, Tinsu Pan

Faculty, Staff and Student Publications

Background: Misregistration between CT and PET data can result in mis-localization and inaccurate quantification of functional uptake in whole body PET/CT imaging. This problem is exacerbated when an abnormal inspiration occurs during the free-breathing helical CT (FB CT) used for attenuation correction of PET data. In data-driven gated (DDG) PET, the data selected for reconstruction is typically derived from the end-expiration (EE) phase of the breathing cycle, making this potential issue worse.

Purpose: The objective of this study is to develop a deformable image registration (DIR)-based respiratory motion model to improve the registration and quantification between misregistered FB CT and …


Incorporating Variable Rbe In Impt Optimization For Ependymoma, Hadis Moazami Goudarzi, Gino Lim, David Grosshans, Radhe Mohan, Wenhua Cao Jan 2024

Incorporating Variable Rbe In Impt Optimization For Ependymoma, Hadis Moazami Goudarzi, Gino Lim, David Grosshans, Radhe Mohan, Wenhua Cao

Faculty, Staff and Student Publications

PURPOSE: To study the dosimetric impact of incorporating variable relative biological effectiveness (RBE) of protons in optimizing intensity-modulated proton therapy (IMPT) treatment plans and to compare it with conventional constant RBE optimization and linear energy transfer (LET)-based optimization.

METHODS: This study included 10 pediatric ependymoma patients with challenging anatomical features for treatment planning. Four plans were generated for each patient according to different optimization strategies: (1) constant RBE optimization (ConstRBEopt) considering standard-of-care dose requirements; (2) LET optimization (LETopt) using a composite cost function simultaneously optimizing dose-averaged LET (LET

RESULTS: We found that the LETopt plans consistently achieved increased LET in …


Investigation Of Autosegmentation Techniques On T2-Weighted Mri For Off-Line Dose Reconstruction In Mr-Linac Workflow For Head And Neck Cancers, Brigid A Mcdonald, Carlos E Cardenas, Nicolette O'Connell, Sara Ahmed, Mohamed A Naser, Kareem A Wahid, Jiaofeng Xu, Dan Thill, Raed J Zuhour, Shane Mesko, Alexander Augustyn, Samantha M Buszek, Stephen Grant, Bhavana V Chapman, Alexander F Bagley, Renjie He, Abdallah S R Mohamed, John Christodouleas, Kristy K Brock, Clifton D Fuller Jan 2024

Investigation Of Autosegmentation Techniques On T2-Weighted Mri For Off-Line Dose Reconstruction In Mr-Linac Workflow For Head And Neck Cancers, Brigid A Mcdonald, Carlos E Cardenas, Nicolette O'Connell, Sara Ahmed, Mohamed A Naser, Kareem A Wahid, Jiaofeng Xu, Dan Thill, Raed J Zuhour, Shane Mesko, Alexander Augustyn, Samantha M Buszek, Stephen Grant, Bhavana V Chapman, Alexander F Bagley, Renjie He, Abdallah S R Mohamed, John Christodouleas, Kristy K Brock, Clifton D Fuller

Faculty, Staff and Student Publications

Background: In order to accurately accumulate delivered dose for head and neck cancer patients treated with the Adapt to Position workflow on the 1.5T magnetic resonance imaging (MRI)-linear accelerator (MR-linac), the low-resolution T2-weighted MRIs used for daily setup must be segmented to enable reconstruction of the delivered dose at each fraction.

Purpose: In this pilot study, we evaluate various autosegmentation methods for head and neck organs at risk (OARs) on on-board setup MRIs from the MR-linac for off-line reconstruction of delivered dose.

Methods: Seven OARs (parotid glands, submandibular glands, mandible, spinal cord, and brainstem) were contoured on 43 images by …