Open Access. Powered by Scholars. Published by Universities.®

Other Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 9 of 9

Full-Text Articles in Other Medicine and Health Sciences

Using Raman Spectroscopy To Improve Hyperpolarized Noble Gas Production For Clinical Lung Imaging Techniques, Jonathan R. Birchall, Nicholas Whiting, Jason G. Skinner, Michael J. Barlow, Boyd M. Goodson Dec 2016

Using Raman Spectroscopy To Improve Hyperpolarized Noble Gas Production For Clinical Lung Imaging Techniques, Jonathan R. Birchall, Nicholas Whiting, Jason G. Skinner, Michael J. Barlow, Boyd M. Goodson

Nicholas Whiting

Spin-exchange optical pumping (SEOP) can be used to “hyperpolarize” 129Xe for human lung MRI. SEOP involves transfer of angular momentum from light to an alkali metal (Rb) vapor, and then onto 129Xe nuclear spins during collisions; collisions between excited Rb and N2 ensure that incident optical energy is nonradiatively converted into heat. However, because variables that govern SEOP are temperature-dependent, the excess heat can complicate efforts to maximize spin polarization—particularly at high laser fluxes and xenon densities. Ultra-low frequency Raman spectroscopy may be used to perform in situ gas temperature measurements to investigate the interplay of energy thermalization and SEOP …


Developing Hyperpolarized Silicon Particles For In Vivo Mri Targeting Of Ovarian Cancer, Nicholas Whiting, Jingzhe Hu, Niki M. Zacharias, Ganesh L. R. Lokesh, David E. Volk, David G. Menter, Rajesha Rupaimoole, Rebecca Previs, Anil K. Sood, Pratip Bhattacharya Aug 2016

Developing Hyperpolarized Silicon Particles For In Vivo Mri Targeting Of Ovarian Cancer, Nicholas Whiting, Jingzhe Hu, Niki M. Zacharias, Ganesh L. R. Lokesh, David E. Volk, David G. Menter, Rajesha Rupaimoole, Rebecca Previs, Anil K. Sood, Pratip Bhattacharya

Nicholas Whiting

Silicon-based nanoparticles are ideally suited for use as biomedical imaging agents due to their biocompatibility, biodegradability, and simple surface chemistry that facilitates drug loading and targeting. A method of hyperpolarizing silicon particles using dynamic nuclear polarization, which increases magnetic resonance imaging signals by several orders-of-magnitude through enhanced nuclear spin alignment, has recently been developed to allow silicon particles to function as contrast agents for in vivo magnetic resonance imaging. The enhanced spin polarization of silicon lasts significantly longer than other hyperpolarized agents (tens of minutes, whereas <1  min for other species at room temperature), allowing a wide range of potential …


Interrogating Metabolism In Brain Cancer, Travis Salzillo, Jingzhe Hu, Linda Nguyen, Nicholas Whiting, Jaehyuk Lee, Joseph Weygand, Prasanta Dutta, Shivanand Pudakalakatti, Niki Zacharias Millward, Seth Gammon, Frederick F. Lang, Amy B. Heimberger, Pratip Bhattacharya Dec 2015

Interrogating Metabolism In Brain Cancer, Travis Salzillo, Jingzhe Hu, Linda Nguyen, Nicholas Whiting, Jaehyuk Lee, Joseph Weygand, Prasanta Dutta, Shivanand Pudakalakatti, Niki Zacharias Millward, Seth Gammon, Frederick F. Lang, Amy B. Heimberger, Pratip Bhattacharya

Nicholas Whiting

Many existing and emerging techniques of interrogating metabolism in brain cancer are at an early stage of development. A few clinical trials that employ these techniques are in progress in patients with brain cancer to establish the clinical efficacy of these techniques. It is likely that in vivo metabolomics and metabolic imaging is the next frontier in brain cancer diagnosis and assessing therapeutic efficacy.


A Parallel-Group Randomized Controlled Trial Of The Boa®-Constricting Iv Band, Richard N. Bradley Dec 2015

A Parallel-Group Randomized Controlled Trial Of The Boa®-Constricting Iv Band, Richard N. Bradley

Richard N Bradley

Background. Few studies have demonstrated the ideal technique for placement of peripheral venous access.

Objectives. The purpose of this study was to conduct a randomized, controlled trial to determine if there was a difference in success rates for establishing peripheral intravenous lines (IVs) when using the BOA® Constricting Band (BOA) compared to a standard elastic tourniquet.

Methods. Eligible participants were paramedics working in the out-of-hospital setting and nurses working in a trauma center. The intervention group intended to use the BOA® for all IV attempts, while the control group intended to use standard elastic tourniquets. The primary outcome was success …


Collaborative Diagnosis: Interdisciplinary Problem-Solving Between Physicians And Lawyers, Robert Pettignano, Lisa Bliss, Sylvia Caley Nov 2015

Collaborative Diagnosis: Interdisciplinary Problem-Solving Between Physicians And Lawyers, Robert Pettignano, Lisa Bliss, Sylvia Caley

Sylvia B. Caley

Patient and client-centered practice and accurate problem diagnosis require that we understand the context within which the patient/clients’ problem originated. Effective problem solving depends upon context-specific solutions. This article describes the interaction of a medical clinician/educator and two legal clinicians/educators who work and teach together as part of an interdisciplinary community collaboration. We demonstrate how a pediatric hospital and two medical schools that treat acutely and chronically ill children collaborate with a legal services clinic based in a law school to provide interdisciplinary clinical education for students and engage in interdisciplinary problem solving for the benefit of patients and clients. …


Real-Time Mri-Guided Catheter Tracking Using Hyperpolarized Silicon Particles, Nicholas Whiting, Jingzhe Hu, Jay V. Shah, Maja C. Cassidy, Erik Cressman, Niki Zacharias Millward, David G. Menter, Charles M. Marcus, Pratip K. Bhattacharya Jan 2015

Real-Time Mri-Guided Catheter Tracking Using Hyperpolarized Silicon Particles, Nicholas Whiting, Jingzhe Hu, Jay V. Shah, Maja C. Cassidy, Erik Cressman, Niki Zacharias Millward, David G. Menter, Charles M. Marcus, Pratip K. Bhattacharya

Nicholas Whiting

Visualizing the movement of angiocatheters during endovascular interventions is typically accomplished using x-ray fluoroscopy. There are many potential advantages to developing magnetic resonance imaging-based approaches that will allow three-dimensional imaging of the tissue/vasculature interface while monitoring other physiologically-relevant criteria, without exposing the patient or clinician team to ionizing radiation. Here we introduce a proof-of-concept development of a magnetic resonance imaging-guided catheter tracking method that utilizes hyperpolarized silicon particles. The increased signal of the silicon particles is generated via low-temperature, solid-state dynamic nuclear polarization, and the particles retain their enhanced signal for ≥40 minutes—allowing imaging experiments over extended time durations. The …


Near-Unity Nuclear Polarization With An Open-Source 129xe Hyperpolarizer For Nmr And Mri, Panayiotis Nikolaou, Aaron M. Coffey, Laura L. Walkup, Brogan M. Gust, Nicholas Whiting, Hayley Newton, Scott Barcus, Iga Muradyan, Mikayel Dabaghyan, Gregory D. Moroz, Matthew S. Rosen, Samuel Patz, Michael J. Barlow, Eduard Y. Chekmenev, Boyd M. Goodson Aug 2013

Near-Unity Nuclear Polarization With An Open-Source 129xe Hyperpolarizer For Nmr And Mri, Panayiotis Nikolaou, Aaron M. Coffey, Laura L. Walkup, Brogan M. Gust, Nicholas Whiting, Hayley Newton, Scott Barcus, Iga Muradyan, Mikayel Dabaghyan, Gregory D. Moroz, Matthew S. Rosen, Samuel Patz, Michael J. Barlow, Eduard Y. Chekmenev, Boyd M. Goodson

Nicholas Whiting

The exquisite NMR spectral sensitivity and negligible reactivity of hyperpolarized xenon-129 (HP129Xe) make it attractive for a number of magnetic resonance applications; moreover, HP129Xe embodies an alternative to rare and nonrenewable 3He. However, the ability to reliably and inexpensively produce large quantities of HP129Xe with sufficiently high 129Xe nuclear spin polarization (PXe) remains a significant challenge—particularly at high Xe densities. We present results from our “open-source” large-scale (∼1 L/h) 129Xe polarizer for clinical, preclinical, and materials NMR and MRI research. Automated and composed mostly of off-the-shelf components, this “hyperpolarizer” is designed to be readily implementable in other laboratories. The device …


Clinical Parameters For Australian Practice: Modes Of Care., Dennis M. Richards Jan 1996

Clinical Parameters For Australian Practice: Modes Of Care., Dennis M. Richards

Dennis M Richards

This document presents, describes, defines, classifies and rates, according to published evidence, procedures commonly used by Australian chiropractors in the care of their patients.


Clinical Parameters For Australian Practice. Modes Of Care, Dennis M. Richards Jan 1995

Clinical Parameters For Australian Practice. Modes Of Care, Dennis M. Richards

Dennis M Richards

In 1994 I was invited to write the ‘Modes of Care’ chapter for the Chiropractors’ Association of Australia’s ‘Clinical Parameters for Australian Practice’ clinical guidelines document. This took over a year of work and the final document I submitted was of 21,285 words and 497 references. It's purpose was to describe and rate procedures commonly used by Australian chiropractors in the care of their patients.