Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Male

Medical Biophysics Publications

Articles 1 - 30 of 33

Full-Text Articles in Medicine and Health Sciences

Chronic Obstructive Pulmonary Disease: Thoracic Ct Texture Analysis And Machine Learning To Predict Pulmonary Ventilation, Andrew Westcott, Dante P I Capaldi, David G Mccormack, Aaron D Ward, Aaron Fenster, Grace Parraga Oct 2019

Chronic Obstructive Pulmonary Disease: Thoracic Ct Texture Analysis And Machine Learning To Predict Pulmonary Ventilation, Andrew Westcott, Dante P I Capaldi, David G Mccormack, Aaron D Ward, Aaron Fenster, Grace Parraga

Medical Biophysics Publications

Background Fixed airflow limitation and ventilation heterogeneity are common in chronic obstructive pulmonary disease (COPD). Conventional noncontrast CT provides airway and parenchymal measurements but cannot be used to directly determine lung function. Purpose To develop, train, and test a CT texture analysis and machine-learning algorithm to predict lung ventilation heterogeneity in participants with COPD. Materials and Methods In this prospective study (


Hyperpolarized Helium 3 Mri In Mild-To-Moderate Asthma: Prediction Of Postbronchodilator Reversibility, Rachel L Eddy, Sarah Svenningsen, Christopher Licskai, David G Mccormack, Grace Parraga Aug 2019

Hyperpolarized Helium 3 Mri In Mild-To-Moderate Asthma: Prediction Of Postbronchodilator Reversibility, Rachel L Eddy, Sarah Svenningsen, Christopher Licskai, David G Mccormack, Grace Parraga

Medical Biophysics Publications

Background: Longitudinal progression to irreversible airflow limitation occurs in approximately 10% of patients with asthma, but it is difficult to identify patients who are at risk for this transition.

Purpose: To investigate 6-year longitudinal changes in hyperpolarized helium 3 (3He) MRI ventilation defects in study participants with mild-to-moderate asthma and identify predictors of longitudinal changes in postbronchodilator forced expiratory volume in 1 second (FEV1) reversibility

Materials and Methods: Spirometry and hyperpolarized 3He MRI were evaluated in participants with mild-to-moderate asthma in two prospectively planned visits approximately 6 years apart. Participants underwent methacholine challenge at baseline (January 2010 to April 2011) …


Oscillometry And Pulmonary Magnetic Resonance Imaging In Asthma And Copd, Rachel L Eddy, Andrew Westcott, Geoffrey N Maksym, Grace Parraga, Ronald J Dandurand Jan 2019

Oscillometry And Pulmonary Magnetic Resonance Imaging In Asthma And Copd, Rachel L Eddy, Andrew Westcott, Geoffrey N Maksym, Grace Parraga, Ronald J Dandurand

Medical Biophysics Publications

Developed over six decades ago, pulmonary oscillometry has re-emerged as a noninvasive and effort-independent method for evaluating respiratory-system impedance in patients with obstructive lung disease. Here, we evaluated the relationships between hyperpolarized


Hyperpolarized 3he Mri Ventilatory Apparent Diffusion Coefficient Of Alpha-1 Antitrypsin, Andrew Westcott, Dante P I Capaldi, Alexei Ouriadov, David G Mccormack, Grace Parraga Jan 2019

Hyperpolarized 3he Mri Ventilatory Apparent Diffusion Coefficient Of Alpha-1 Antitrypsin, Andrew Westcott, Dante P I Capaldi, Alexei Ouriadov, David G Mccormack, Grace Parraga

Medical Biophysics Publications

Alpha-1 antitrypsin deficiency (AATD) leads to disabling chronic obstructive pulmonary disease (COPD). Current therapy aimed at slowing lung disease progression includes exogenous alpha-1 antitrypsin augmentation therapy, but there are few potential new treatments under development. Currently used measurements of AATD-related emphysema include the forced expiratory volume in 1 second (FEV1) and the diffusing capacity of carbon monoxide (DLCO); both are relatively insensitive to therapy, although computed tomography (CT) lung density measurements have been shown to worsen more slowly in treated patients.


Oscillometry And Pulmonary Mri Measurements Of Ventilation Heterogeneity In Obstructive Lung Disease: Relationship To Quality Of Life And Disease Control, Heather M Young, Fumin Guo, Rachel L Eddy, Geoffrey Maksym, Grace Parraga Jul 2018

Oscillometry And Pulmonary Mri Measurements Of Ventilation Heterogeneity In Obstructive Lung Disease: Relationship To Quality Of Life And Disease Control, Heather M Young, Fumin Guo, Rachel L Eddy, Geoffrey Maksym, Grace Parraga

Medical Biophysics Publications

Ventilation heterogeneity is a hallmark finding in obstructive lung disease and may be evaluated using a variety of methods, including multiple-breath gas washout and pulmonary imaging. Such methods provide an opportunity to better understand the relationships between structural and functional abnormalities in the lungs, and their relationships with important clinical outcomes. We measured ventilation heterogeneity and respiratory impedance in 100 subjects [50 patients with asthma, 22 ex-smokers, and 28 patients with chronic obstructive pulmonary disease (COPD)] using oscillometry and hyperpolarized


Predictive Value For Cardiovascular Events Of Common Carotid Intima Media Thickness And Its Rate Of Change In Individuals At High Cardiovascular Risk - Results From The Prog-Imt Collaboration, Matthias W Lorenz, Lu Gao, Kathrin Ziegelbauer, Giuseppe Danilo Norata, Jean Philippe Empana, Irene Schmidtmann, Hung-Ju Lin, Stela Mclachlan, Lena Bokemark, Kimmo Ronkainen, Mauro Amato, Ulf Schminke, Sathanur R Srinivasan, Lars Lind, Shuhei Okazaki, Coen D A Stehouwer, Peter Willeit, Joseph F Polak, Helmuth Steinmetz, Dirk Sander, Holger Poppert, Moise Desvarieux, M Arfan Ikram, Stein Harald Johnsen, Daniel Staub, Cesare R Sirtori, Bernhard Iglseder, Oscar Beloqui, Gunnar Engström, Alfonso Friera, Francesco Rozza, Wuxiang Xie, Grace Parraga, Liliana Grigore, Matthieu Plichart, Stefan Blankenberg, Ta-Chen Su, Caroline Schmidt, Tomi-Pekka Tuomainen, Fabrizio Veglia, Henry Völzke, Giel Nijpels, Johann Willeit, Ralph L Sacco, Oscar H Franco, Heiko Uthoff, Bo Hedblad, Carmen Suarez, Raffaele Izzo, Dong Zhao, Thapat Wannarong, Alberico Catapano, Pierre Ducimetiere, Christine Espinola-Klein, Kuo-Liong Chien, Jackie F Price, Göran Bergström, Jussi Kauhanen, Elena Tremoli, Marcus Dörr, Gerald Berenson, Kazuo Kitagawa, Jacqueline M Dekker, Stefan Kiechl, Matthias Sitzer, Horst Bickel, Tatjana Rundek, Albert Hofman, Ellisiv B Mathiesen, Samuela Castelnuovo, Manuel F Landecho, Maria Rosvall, Rafael Gabriel, Nicola De Luca, Jing Liu, Damiano Baldassarre, Maryam Kavousi, Eric De Groot, Michiel L Bots, David N Yanez, Simon G Thompson Apr 2018

Predictive Value For Cardiovascular Events Of Common Carotid Intima Media Thickness And Its Rate Of Change In Individuals At High Cardiovascular Risk - Results From The Prog-Imt Collaboration, Matthias W Lorenz, Lu Gao, Kathrin Ziegelbauer, Giuseppe Danilo Norata, Jean Philippe Empana, Irene Schmidtmann, Hung-Ju Lin, Stela Mclachlan, Lena Bokemark, Kimmo Ronkainen, Mauro Amato, Ulf Schminke, Sathanur R Srinivasan, Lars Lind, Shuhei Okazaki, Coen D A Stehouwer, Peter Willeit, Joseph F Polak, Helmuth Steinmetz, Dirk Sander, Holger Poppert, Moise Desvarieux, M Arfan Ikram, Stein Harald Johnsen, Daniel Staub, Cesare R Sirtori, Bernhard Iglseder, Oscar Beloqui, Gunnar Engström, Alfonso Friera, Francesco Rozza, Wuxiang Xie, Grace Parraga, Liliana Grigore, Matthieu Plichart, Stefan Blankenberg, Ta-Chen Su, Caroline Schmidt, Tomi-Pekka Tuomainen, Fabrizio Veglia, Henry Völzke, Giel Nijpels, Johann Willeit, Ralph L Sacco, Oscar H Franco, Heiko Uthoff, Bo Hedblad, Carmen Suarez, Raffaele Izzo, Dong Zhao, Thapat Wannarong, Alberico Catapano, Pierre Ducimetiere, Christine Espinola-Klein, Kuo-Liong Chien, Jackie F Price, Göran Bergström, Jussi Kauhanen, Elena Tremoli, Marcus Dörr, Gerald Berenson, Kazuo Kitagawa, Jacqueline M Dekker, Stefan Kiechl, Matthias Sitzer, Horst Bickel, Tatjana Rundek, Albert Hofman, Ellisiv B Mathiesen, Samuela Castelnuovo, Manuel F Landecho, Maria Rosvall, Rafael Gabriel, Nicola De Luca, Jing Liu, Damiano Baldassarre, Maryam Kavousi, Eric De Groot, Michiel L Bots, David N Yanez, Simon G Thompson

Medical Biophysics Publications

AIMS: Carotid intima media thickness (CIMT) predicts cardiovascular (CVD) events, but the predictive value of CIMT change is debated. We assessed the relation between CIMT change and events in individuals at high cardiovascular risk.

METHODS AND RESULTS: From 31 cohorts with two CIMT scans (total n = 89070) on average 3.6 years apart and clinical follow-up, subcohorts were drawn: (A) individuals with at least 3 cardiovascular risk factors without previous CVD events, (B) individuals with carotid plaques without previous CVD events, and (C) individuals with previous CVD events. Cox regression models were fit to estimate the hazard ratio (HR) of …


Free-Breathing Pulmonary Mr Imaging To Quantify Regional Ventilation, Dante P I Capaldi, Rachel L Eddy, Sarah Svenningsen, Fumin Guo, John S H Baxter, A Jonathan Mcleod, Parameswaran Nair, David G Mccormack, Grace Parraga Feb 2018

Free-Breathing Pulmonary Mr Imaging To Quantify Regional Ventilation, Dante P I Capaldi, Rachel L Eddy, Sarah Svenningsen, Fumin Guo, John S H Baxter, A Jonathan Mcleod, Parameswaran Nair, David G Mccormack, Grace Parraga

Medical Biophysics Publications

Purpose: To measure regional specific ventilation with free-breathing hydrogen 1 (1H) magnetic resonance (MR) imaging without exogenous contrast material and to investigate correlations with hyperpolarized helium 3 (3He) MR imaging and pulmonary function test measurements in healthy volunteers and patients with asthma.

Materials and Methods: Subjects underwent free-breathing 1H and static breath-hold hyperpolarized 3He MR imaging as well as spirometry and plethysmography; participants were consecutively recruited between January and June 2017. Free-breathing 1H MR imaging was performed with an optimized balanced steady-state free-precession sequence; images were retrospectively grouped into tidal inspiration or tidal expiration volumes with exponentially weighted phase interpolation. …


Mri Ventilation Abnormalities Predict Quality-Of-Life And Lung Function Changes In Mild-To-Moderate Copd: Longitudinal Tincan Study, Miranda Kirby, Rachel L Eddy, Damien Pike, Sarah Svenningsen, Harvey O Coxson, Don D Sin, David G Mccormack, Grace Parraga Mar 2017

Mri Ventilation Abnormalities Predict Quality-Of-Life And Lung Function Changes In Mild-To-Moderate Copd: Longitudinal Tincan Study, Miranda Kirby, Rachel L Eddy, Damien Pike, Sarah Svenningsen, Harvey O Coxson, Don D Sin, David G Mccormack, Grace Parraga

Medical Biophysics Publications

CT biomarkers of emphysema (15th percentile of the CT density histogram, HU15%) and airways disease (wall thickness of airways with 10 mm internal perimeter, Pi10) have shown promise for providing prognostic information.2 Although recent data3 showed that the change in CT emphysema may be used to estimate the efficacy of therapy in patients with α-1-antitrypsin-deficiency, thus far none of the currently developed CT biomarkers have been shown to reflect changes in outcomes that are important to patients with COPD. MRI with inhaled noble gases provide highly sensitive and unique microstructural and functional information in COPD.4 MRI biomarkers of COPD are …


Design, Development And Evaluation Of A Compact Telerobotic Catheter Navigation System., Mohammad Ali Tavallaei, Daniel Gelman, Michael Konstantine Lavdas, Allan C Skanes, Douglas L Jones, Jeffrey S Bax, Maria Drangova Sep 2016

Design, Development And Evaluation Of A Compact Telerobotic Catheter Navigation System., Mohammad Ali Tavallaei, Daniel Gelman, Michael Konstantine Lavdas, Allan C Skanes, Douglas L Jones, Jeffrey S Bax, Maria Drangova

Medical Biophysics Publications

BACKGROUND: Remote catheter navigation systems protect interventionalists from scattered ionizing radiation. However, these systems typically require specialized catheters and extensive operator training.

METHODS: A new compact and sterilizable telerobotic system is described, which allows remote navigation of conventional tip-steerable catheters, with three degrees of freedom, using an interface that takes advantage of the interventionalist's existing dexterity skills. The performance of the system is evaluated ex vivo and in vivo for remote catheter navigation and ablation delivery.

RESULTS: The system has absolute errors of 0.1 ± 0.1 mm and 7 ± 6° over 100 mm of axial motion and 360° of …


Hyperpolarized 3he Magnetic Resonance Imaging Ventilation Defects In Asthma: Relationship To Airway Mechanics, Del Leary, Sarah Svenningsen, Fumin Guo, Swati Bhatawadekar, Grace Parraga, Geoffrey N Maksym Apr 2016

Hyperpolarized 3he Magnetic Resonance Imaging Ventilation Defects In Asthma: Relationship To Airway Mechanics, Del Leary, Sarah Svenningsen, Fumin Guo, Swati Bhatawadekar, Grace Parraga, Geoffrey N Maksym

Medical Biophysics Publications

In patients with asthma, magnetic resonance imaging (MRI) provides direct measurements of regional ventilation heterogeneity, the etiology of which is not well-understood, nor is the relationship of ventilation abnormalities with lung mechanics. In addition, respiratory resistance and reactance are often abnormal in asthmatics and the frequency dependence of respiratory resistance is thought to reflect ventilation heterogeneity. We acquiredMRIventilation defect maps, forced expiratory volume in one-second (FEV1), and airways resistance (Raw) measurements, and used a computational airway model to explore the relationship of ventilation defect percent (VDP) with simulated measurements of respiratory system resistance (Rrs) and reactance (Xrs).MRIventilation defect maps were …


Pulmonary Imaging Biomarkers Of Gas Trapping And Emphysema In Copd: (3)He Mr Imaging And Ct Parametric Response Maps, Dante P I Capaldi, Nanxi Zha, Fumin Guo, Damien Pike, David G Mccormack, Miranda Kirby, Grace Parraga Jan 2016

Pulmonary Imaging Biomarkers Of Gas Trapping And Emphysema In Copd: (3)He Mr Imaging And Ct Parametric Response Maps, Dante P I Capaldi, Nanxi Zha, Fumin Guo, Damien Pike, David G Mccormack, Miranda Kirby, Grace Parraga

Medical Biophysics Publications

PURPOSE: To directly compare magnetic resonance (MR) imaging and computed tomography (CT) parametric response map (PRM) measurements of gas trapping and emphysema in ex-smokers both with and without chronic obstructive pulmonary disease (COPD).

MATERIALS AND METHODS: Participants provided written informed consent to a protocol that was approved by a local research ethics board and Health Canada and was compliant with the HIPAA (Institutional Review Board Reg. #00000940). The prospectively planned study was performed from March 2014 to December 2014 and included 58 ex-smokers (mean age, 73 years ± 9) with (n = 32; mean age, 74 years ± 7) and …


Copd: Do Imaging Measurements Of Emphysema And Airway Disease Explain Symptoms And Exercise Capacity?, Miranda Kirby, Damien Pike, Don D Sin, Harvey O Coxson, David G Mccormack, Grace Parraga Jul 2015

Copd: Do Imaging Measurements Of Emphysema And Airway Disease Explain Symptoms And Exercise Capacity?, Miranda Kirby, Damien Pike, Don D Sin, Harvey O Coxson, David G Mccormack, Grace Parraga

Medical Biophysics Publications

PURPOSE: To determine the role of imaging measurements of emphysema and airway disease in determining chronic obstructive pulmonary disease (COPD) symptoms and exercise limitation in patients with COPD, particularly in patients with mild-to-moderate disease.

MATERIALS AND METHODS: Participants (n = 116) with Global Initiative for Chronic Obstructive Lung Disease (GOLD) grade U (unclassified) or grade I-IV COPD provided informed consent to an ethics board-approved HIPAA-compliant protocol and underwent spirometry and plethysmography, completed the St George's Respiratory Questionnaire (SGRQ), completed a 6-minute walk test for the 6-minute walk distance (6MWD), and underwent hyperpolarized helium 3 ((3)He) magnetic resonance (MR) imaging and …


Ventilation Heterogeneity In Ex-Smokers Without Airflow Limitation., Damien Pike, Miranda Kirby, Fumin Guo, David G Mccormack, Grace Parraga May 2015

Ventilation Heterogeneity In Ex-Smokers Without Airflow Limitation., Damien Pike, Miranda Kirby, Fumin Guo, David G Mccormack, Grace Parraga

Medical Biophysics Publications

RATIONALE AND OBJECTIVES: Hyperpolarized (3)He magnetic resonance imaging (MRI) ventilation abnormalities are visible in ex-smokers without airflow limitation, but the clinical relevance of this is not well-understood. Our objective was to phenotype healthy ex-smokers with normal and abnormally elevated ventilation defect percent (VDP).

MATERIALS AND METHODS: Sixty ex-smokers without airflow limitation provided written informed consent to (3)He MRI, computed tomography (CT), and pulmonary function tests in a single visit. (3)He MRI VDP and apparent diffusion coefficients (ADCs) were measured for whole-lung and each lung lobe as were CT measurements of emphysema (relative area [RA] with attenuation ≤-950 HU, RA950) and …


Ct Perfusion Imaging As An Early Biomarker Of Differential Response To Stereotactic Radiosurgery In C6 Rat Gliomas, Timothy Pok Chi Yeung, Maher Kurdi, Yong Wang, Baraa Al-Khazraji, Laura Morrison, Lisa Hoffman, Dwayne Jackson, Cathie Crukley, Ting-Yim Lee, Glenn Bauman, Slav Yartsev Oct 2014

Ct Perfusion Imaging As An Early Biomarker Of Differential Response To Stereotactic Radiosurgery In C6 Rat Gliomas, Timothy Pok Chi Yeung, Maher Kurdi, Yong Wang, Baraa Al-Khazraji, Laura Morrison, Lisa Hoffman, Dwayne Jackson, Cathie Crukley, Ting-Yim Lee, Glenn Bauman, Slav Yartsev

Medical Biophysics Publications

BACKGROUND: The therapeutic efficacy of stereotactic radiosurgery for glioblastoma is not well understood, and there needs to be an effective biomarker to identify patients who might benefit from this treatment. This study investigated the efficacy of computed tomography (CT) perfusion imaging as an early imaging biomarker of response to stereotactic radiosurgery in a malignant rat glioma model.

METHODS: Rats with orthotopic C6 glioma tumors received either mock irradiation (controls, N = 8) or stereotactic radiosurgery (N = 25, 12 Gy in one fraction) delivered by Helical Tomotherapy. Twelve irradiated animals were sacrificed four days after stereotactic radiosurgery to assess acute …


Pulmonary Ventilation Defects In Older Never-Smokers, Khadija Sheikh, Gregory A Paulin, Sarah Svenningsen, Miranda Kirby, Nigel A M Paterson, David G Mccormack, Grace Parraga Aug 2014

Pulmonary Ventilation Defects In Older Never-Smokers, Khadija Sheikh, Gregory A Paulin, Sarah Svenningsen, Miranda Kirby, Nigel A M Paterson, David G Mccormack, Grace Parraga

Medical Biophysics Publications

Hyperpolarized (3)He MRI previously revealed spatially persistent ventilation defects in healthy, older compared with healthy, younger never-smokers. To understand better the physiological consequences and potential relevance of (3)He MRI ventilation defects, we evaluated (3)He-MRI ventilation-defect percent (VDP) and the effect of deep inspiration (DI) and salbutamol on VDP in older never-smokers. To identify the potential determinants of ventilation defects in these subjects, we evaluated dyspnea, pulmonary function, and cardiopulmonary exercise test (CPET) measurements, as well as occupational and second-hand smoke exposure. Fifty-two never-smokers (71 ± 6 yr) with no history of chronic respiratory disease were evaluated. During a single visit, …


Three-Dimensional Carotid Ultrasound Plaque Texture Predicts Vascular Events, Arna Van Engelen, Thapat Wannarong, Grace Parraga, Wiro J Niessen, Aaron Fenster, J David Spence, Marleen De Bruijne Jul 2014

Three-Dimensional Carotid Ultrasound Plaque Texture Predicts Vascular Events, Arna Van Engelen, Thapat Wannarong, Grace Parraga, Wiro J Niessen, Aaron Fenster, J David Spence, Marleen De Bruijne

Medical Biophysics Publications

BACKGROUND AND PURPOSE: Carotid ultrasound atherosclerosis measurements, including those of the arterial wall and plaque, provide a way to monitor patients at risk of vascular events. Our objective was to examine carotid ultrasound plaque texture measurements and the change in carotid plaque texture during 1 year in patients at risk of events and to compare these with measurements of plaque volume and other risk factors as predictors of vascular events.

METHODS: We evaluated 298 patients with carotid atherosclerosis using 3-dimensional (3D) ultrasound at baseline and after 1 year and measured carotid plaque volume and 376 measures of plaque texture. Patients …


Volume Of Carotid Artery Ulceration As A Predictor Of Cardiovascular Events, Mariya Kuk, Thapat Wannarong, Vadim Beletsky, Grace Parraga, Aaron Fenster, J David Spence May 2014

Volume Of Carotid Artery Ulceration As A Predictor Of Cardiovascular Events, Mariya Kuk, Thapat Wannarong, Vadim Beletsky, Grace Parraga, Aaron Fenster, J David Spence

Medical Biophysics Publications

BACKGROUND AND PURPOSE: Previous studies have shown the presence of ulceration in atherosclerotic plaque either by categorizing the plaque as complex (irregular morphology with ulcers) or smooth or by quantifying the number of ulcers observed in a specific region of interest. The aim of this study was to quantify carotid total ulcer volume by 3-dimensional ultrasound to investigate the relationship of total ulcer volume to vascular events (strokes, transient ischemic attack, myocardial infarction, revascularization, or death because of cardiovascular reasons).

METHODS: In total, 349 at-risk subjects provided written informed consent to carotid 3-dimensional ultrasound and were analyzed for ulcerations. Ulcer …


Characterization Of A Far-Red Analog Of Ghrelin For Imaging Ghs-R In P19-Derived Cardiomyocytes., Gregory A F Douglas, Rebecca Mcgirr, Carlie L Charlton, Dov B Kagan, Lisa M Hoffman, Leonard G Luyt, Savita Dhanvantari Apr 2014

Characterization Of A Far-Red Analog Of Ghrelin For Imaging Ghs-R In P19-Derived Cardiomyocytes., Gregory A F Douglas, Rebecca Mcgirr, Carlie L Charlton, Dov B Kagan, Lisa M Hoffman, Leonard G Luyt, Savita Dhanvantari

Medical Biophysics Publications

Ghrelin and its receptor, the growth hormone secretagogue receptor (GHS-R), are expressed in the heart, and may function to promote cardiomyocyte survival, differentiation and contractility. Previously, we had generated a truncated analog of ghrelin conjugated to fluorescein isothiocyanate for the purposes of determining GHS-R expression in situ. We now report the generation and characterization of a far-red ghrelin analog, [Dpr(3)(octanoyl), Lys(19)(Cy5)]ghrelin (1-19), and show that it can be used to image changes in GHS-R in developing cardiomyocytes. We also generated the des-acyl analog, des-acyl [Lys(19)(Cy5)]ghrelin (1-19) and characterized its binding to mouse heart sections. Receptor binding affinity of Cy5-ghrelin as …


What Are Ventilation Defects In Asthma?, Sarah Svenningsen, Miranda Kirby, Danielle Starr, Harvey O Coxson, Nigel A M Paterson, David G Mccormack, Grace Parraga Jan 2014

What Are Ventilation Defects In Asthma?, Sarah Svenningsen, Miranda Kirby, Danielle Starr, Harvey O Coxson, Nigel A M Paterson, David G Mccormack, Grace Parraga

Medical Biophysics Publications

BACKGROUND: Hyperpolarised (3)He MRI provides a way to visualise regional pulmonary functional abnormalities that in asthma are thought to be related to airway morphological abnormalities. However, the exact aetiology of ventilation defects in asthma is not well understood.

OBJECTIVE: To better understand the determinants of ventilation defects in asthma, we evaluated well-established clinical as well as (3)He MRI and X-ray CT airway measurements in healthy subjects and subjects with asthma.

METHODS: Thirty-four subjects (n=26 subjects with asthma, n=8 healthy volunteers) underwent MRI, spirometry, plethysmography, fraction of exhaled nitric oxide analysis, methacholine challenge and CT for a region-of-interest proximal to ventilation …


One, Two And Three-Dimensional Ultrasound Measurements Of Carotid Atherosclerosis Before And After Cardiac Rehabilitation: Preliminary Results Of A Randomized Controlled Trial., Tamas J Lindenmaier, Daniel N Buchanan, Damien Pike, Tim Hartley, Robert D Reid, J David Spence, Richard Chan, Michael Sharma, Peter L Prior, Neville Suskin, Grace Parraga Nov 2013

One, Two And Three-Dimensional Ultrasound Measurements Of Carotid Atherosclerosis Before And After Cardiac Rehabilitation: Preliminary Results Of A Randomized Controlled Trial., Tamas J Lindenmaier, Daniel N Buchanan, Damien Pike, Tim Hartley, Robert D Reid, J David Spence, Richard Chan, Michael Sharma, Peter L Prior, Neville Suskin, Grace Parraga

Medical Biophysics Publications

BACKGROUND: It is still not known how patients who are post-transient ischemic attack (TIA) or post-stroke might benefit from prospectively planned comprehensive cardiac rehabilitation (CCR). In this pilot evaluation of a larger ongoing randomized-controlled-trial, we evaluated ultrasound (US) measurements of carotid atherosclerosis in subjects following TIA or mild non-disabling stroke and their relationship with risk factors before and after 6-months of CCR.

METHODS: Carotid ultrasound (US) measurements of one-dimensional intima-media-thickness (IMT), two-dimensional total-plaque-area (TPA), three-dimensional total-plaque-volume (TPV) and vessel-wall-volume (VWV) were acquired before and after 6-months CCR for 39 subjects who had previously experienced a TIA and provided written informed …


Progression Of Carotid Plaque Volume Predicts Cardiovascular Events, Thapat Wannarong, Grace Parraga, Daniel Buchanan, Aaron Fenster, Andrew A House, Daniel G Hackam, J David Spence Jul 2013

Progression Of Carotid Plaque Volume Predicts Cardiovascular Events, Thapat Wannarong, Grace Parraga, Daniel Buchanan, Aaron Fenster, Andrew A House, Daniel G Hackam, J David Spence

Medical Biophysics Publications

BACKGROUND AND PURPOSE: Carotid ultrasound evaluation of intima-media thickness (IMT) and plaque burden has been used for risk stratification and for evaluation of antiatherosclerotic therapies. Increasing evidence indicates that measuring plaque burden is superior to measuring IMT for both purposes. We compared progression/regression of IMT, total plaque area (TPA), and total plaque volume (TPV) as predictors of cardiovascular outcomes.

METHODS: IMT, TPA, and TPV were measured at baseline in 349 patients attending vascular prevention clinics; they had TPA of 40 to 600 mm(2) at baseline to qualify for enrollment. Participants were followed up for ≤5 years (median, 3.17 years) to …


On The Role Of Abnormal Dl(Co) In Ex-Smokers Without Airflow Limitation: Symptoms, Exercise Capacity And Hyperpolarised Helium-3 Mri, Miranda Kirby, Amir Owrangi, Sarah Svenningsen, Andrew Wheatley, Harvey O Coxson, Nigel A M Paterson, David G Mccormack, Grace Parraga Apr 2013

On The Role Of Abnormal Dl(Co) In Ex-Smokers Without Airflow Limitation: Symptoms, Exercise Capacity And Hyperpolarised Helium-3 Mri, Miranda Kirby, Amir Owrangi, Sarah Svenningsen, Andrew Wheatley, Harvey O Coxson, Nigel A M Paterson, David G Mccormack, Grace Parraga

Medical Biophysics Publications

BACKGROUND: The functional effects of abnormal diffusing capacity for carbon monoxide (DLCO) in ex-smokers without chronic obstructive pulmonary disease (COPD) are not well understood.

OBJECTIVE: We aimed to evaluate and compare well established clinical, physiological and emerging imaging measurements in ex-smokers with normal spirometry and abnormal DLCO with a group of ex-smokers with normal spirometry and DLCO and ex-smokers with Global Initiative for Chronic Obstructive Lung Disease (GOLD) stage I COPD.

METHODS: We enrolled 38 ex-smokers and 15 subjects with stage I COPD who underwent spirometry, plethysmography, St George's Respiratory Questionnaire (SGRQ), 6 min Walk Test (6MWT), x-ray CT and …


Hyperpolarized 3he And 129xe Mr Imaging In Healthy Volunteers And Patients With Chronic Obstructive Pulmonary Disease, Miranda Kirby, Sarah Svenningsen, Amir Owrangi, Andrew Wheatley, Adam Farag, Alexei Ouriadov, Giles E Santyr, Roya Etemad-Rezai, Harvey O Coxson, David G Mccormack, Grace Parraga Sep 2012

Hyperpolarized 3he And 129xe Mr Imaging In Healthy Volunteers And Patients With Chronic Obstructive Pulmonary Disease, Miranda Kirby, Sarah Svenningsen, Amir Owrangi, Andrew Wheatley, Adam Farag, Alexei Ouriadov, Giles E Santyr, Roya Etemad-Rezai, Harvey O Coxson, David G Mccormack, Grace Parraga

Medical Biophysics Publications

PURPOSE: To quantitatively compare hyperpolarized helium 3 (3He) and xenon 129 (129Xe) magnetic resonance (MR) images obtained within 5 minutes in healthy volunteers and patients with chronic obstructive pulmonary disease (COPD) and to evaluate the correlations between 3He and 129Xe MR imaging measurements and those from spirometry and plethysmography.

MATERIALS AND METHODS: This study was approved by an ethics board and compliant with HIPAA. Written informed consent was obtained from all subjects. Eight healthy volunteers and 10 patients with COPD underwent MR imaging, spirometry, and plethysmography. Ventilation defect percentages (VDPs) at 3He and 129Xe imaging were obtained by using semiautomated …


Quantitative Pulmonary Imaging Using Computed Tomography And Magnetic Resonance Imaging, George R Washko, Grace Parraga, Harvey O Coxson Apr 2012

Quantitative Pulmonary Imaging Using Computed Tomography And Magnetic Resonance Imaging, George R Washko, Grace Parraga, Harvey O Coxson

Medical Biophysics Publications

Measurements of lung function, including spirometry and body plethesmography, are easy to perform and are the current clinical standard for assessing disease severity. However, these lung functional techniques do not adequately explain the observed variability in clinical manifestations of disease and offer little insight into the relationship of lung structure and function. Lung imaging and the image-based assessment of lung disease has matured to the extent that it is common for clinical, epidemiologic and genetic investigation to have a component dedicated to image analysis. There are several exciting imaging modalities currently being used for the non-invasive study of lung anatomy …


Evaluating Bronchodilator Effects In Chronic Obstructive Pulmonary Disease Using Diffusion-Weighted Hyperpolarized Helium-3 Magnetic Resonance Imaging, Miranda Kirby, Mohammadreza Heydarian, Andrew Wheatley, David G Mccormack, Grace Parraga Feb 2012

Evaluating Bronchodilator Effects In Chronic Obstructive Pulmonary Disease Using Diffusion-Weighted Hyperpolarized Helium-3 Magnetic Resonance Imaging, Miranda Kirby, Mohammadreza Heydarian, Andrew Wheatley, David G Mccormack, Grace Parraga

Medical Biophysics Publications

The objective of this study was to evaluate the regional effects of bronchodilator administration in chronic obstructive pulmonary disease (COPD) using hyperpolarized helium-3 ((3)He) MRI apparent diffusion coefficient (ADC). Ten COPD ex-smokers provided written, informed consent and underwent diffusion-weighted, hyperpolarized (3)He MRI, spirometry, and plethysmography before and 25 ± 2 min after bronchodilator administration. Pre- and postsalbutamol whole-lung (WL) ADC maps were generated and registered together to identify the lung regions containing the (3)He signal at both time points, and mean ADC within those regions of interest (ROI) was determined for a measurement of previously ventilated ROI ADC (ADC(P)). Lung …


Chest Mri In Children: Why Bother?, Amir M Owrangi, Grace Parraga Jan 2012

Chest Mri In Children: Why Bother?, Amir M Owrangi, Grace Parraga

Medical Biophysics Publications

In this issue of Respirology, Montella and colleagues ask this question: How does high‐field chest MRI compare with CT of children with non‐cystic fibrosis (CF) lung disease? In an important extension of the first description of this study where they compared MRI and CT with pulmonary function measurements, the authors evaluated how widely‐used chest CT and almost never‐utilized lung MRI compare for diagnostic imaging of chronic lung disease. Here they show that high‐field (3Tesla as compared with the 1.5Tesla clinical standard) thoracic MRI has high reliability and good‐to‐excellent agreement with CT, definitively answering the important question at hand; their results …


Hyperpolarized 3he Functional Magnetic Resonance Imaging Of Bronchoscopic Airway Bypass In Chronic Obstructive Pulmonary Disease., Lindsay Mathew, Miranda Kirby, Donald Farquhar, Christopher Licskai, Giles Santyr, Roya Etemad-Rezai, Grace Parraga, David G Mccormack Jan 2012

Hyperpolarized 3he Functional Magnetic Resonance Imaging Of Bronchoscopic Airway Bypass In Chronic Obstructive Pulmonary Disease., Lindsay Mathew, Miranda Kirby, Donald Farquhar, Christopher Licskai, Giles Santyr, Roya Etemad-Rezai, Grace Parraga, David G Mccormack

Medical Biophysics Publications

A 73-year-old exsmoker with Global initiative for chronic Obstructive Lung Disease stage III chronic obstructive pulmonary disease underwent airway bypass (AB) as part of the Exhale Airway Stents for Emphysema (EASE) trial, and was the only EASE subject to undergo hyperpolarized 3He magnetic resonance imaging for evaluation of lung function pre- and post-AB. 3He magnetic resonance imaging was acquired twice previously (32 and eight months pre-AB) and twice post-AB (six and 12 months post-AB). Six months post-AB, his increase in forced vital capacity was


Chronic Obstructive Pulmonary Disease: Quantification Of Bronchodilator Effects By Using Hyperpolarized ³He Mr Imaging, Miranda Kirby, Lindsay Mathew, Mohammadreza Heydarian, Roya Etemad-Rezai, David G Mccormack, Grace Parraga Oct 2011

Chronic Obstructive Pulmonary Disease: Quantification Of Bronchodilator Effects By Using Hyperpolarized ³He Mr Imaging, Miranda Kirby, Lindsay Mathew, Mohammadreza Heydarian, Roya Etemad-Rezai, David G Mccormack, Grace Parraga

Medical Biophysics Publications

PURPOSE: To evaluate short-acting bronchodilator effects in chronic obstructive pulmonary disease (COPD) by using hyperpolarized helium 3 (³He) magnetic resonance (MR) imaging, spirometry, and plethysmography.

MATERIALS AND METHODS: Fourteen ex-smokers with COPD provided written informed consent to a local ethics board-approved and Health Insurance and Portability Accountability Act-compliant protocol and underwent hyperpolarized ³He and hydrogen 1 MR imaging, spirometry, and plethysmography before and a mean of 25 minutes ± 2 (standard deviation) after administration of 400 μg salbutamol. Distribution of ³He gas was evaluated by using semiautomated segmentation of ³He voxel intensities, where cluster 1 represented regions of signal void …


Hyperpolarized (3)He Magnetic Resonance Imaging-Derived Pulmonary Pressure-Volume Curves, Stephen Choy, Andrew Wheatley, David G Mccormack, Grace Parraga Aug 2010

Hyperpolarized (3)He Magnetic Resonance Imaging-Derived Pulmonary Pressure-Volume Curves, Stephen Choy, Andrew Wheatley, David G Mccormack, Grace Parraga

Medical Biophysics Publications

We aimed to evaluate the potential for the use of hyperpolarized helium-3 magnetic resonance imaging (MRI) apparent diffusion coefficient (ADC) surrogates of alveolar size, together with literature-based morphological parameters in a theoretical model of lung mechanics to simulate noninvasive transpulmonary pressure-volume curves. Fourteen ex-smokers with chronic obstructive pulmonary disease (COPD) (n = 8 stage II, n = 6 stage III/IV COPD) and five age-matched never-smokers, provided written, informed consent and were evaluated at baseline and 26 + or - 2 mo later (n = 15 subjects) using plethysmography, spirometry, and (3)He MRI at 3.0 T. Total lung capacity, residual volume, …


Chronic Obstructive Pulmonary Disease: Longitudinal Hyperpolarized (3)He Mr Imaging, Miranda Kirby, Lindsay Mathew, Andrew Wheatley, Giles E Santyr, David G Mccormack, Grace Parraga Jul 2010

Chronic Obstructive Pulmonary Disease: Longitudinal Hyperpolarized (3)He Mr Imaging, Miranda Kirby, Lindsay Mathew, Andrew Wheatley, Giles E Santyr, David G Mccormack, Grace Parraga

Medical Biophysics Publications

PURPOSE: To quantitatively evaluate a small pilot group of ex-smokers with chronic obstructive pulmonary disease (COPD) and healthy volunteers during approximately 2 years by using hyperpolarized helium 3 ((3)He) magnetic resonance (MR) imaging.

MATERIALS AND METHODS: All subjects provided written informed consent to the study protocol, which was approved by the local research ethics board and Health Canada and was compliant with the Personal Information Protection and Electronic Documents Act and HIPAA. Hyperpolarized (3)He MR imaging, hydrogen 1 MR imaging, spirometry, and plethysmography were performed in 15 ex-smokers with COPD and five healthy volunteers (with the same mean age and …