Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Humans

Dartmouth Scholarship

2013

Analytical, Diagnostic and Therapeutic Techniques and Equipment

Articles 1 - 2 of 2

Full-Text Articles in Medicine and Health Sciences

Feasibility Of Tomotherapy-Based Image-Guided Radiotherapy To Reduce Aspiration Risk In Patients With Non-Laryngeal And Non-Pharyngeal Head And Neck Cancer, Nam P. Nguyen, Lexie Smith-Raymond, Vincent Vinh-Hung, Paul Vos, Rick Davis, Anand Desai, Thomas Sroka Mar 2013

Feasibility Of Tomotherapy-Based Image-Guided Radiotherapy To Reduce Aspiration Risk In Patients With Non-Laryngeal And Non-Pharyngeal Head And Neck Cancer, Nam P. Nguyen, Lexie Smith-Raymond, Vincent Vinh-Hung, Paul Vos, Rick Davis, Anand Desai, Thomas Sroka

Dartmouth Scholarship

Purpose: The study aims to assess the feasibility of Tomotherapy-based image-guided radiotherapy (IGRT) to reduce the aspiration risk in patients with non-laryngeal and non-hypopharyngeal cancer. A retrospective review of 48 patients undergoing radiation for non-laryngeal and non-hypopharyngeal head and neck cancers was conducted. All patients had a modified barium swallow (MBS) prior to treatment, which was repeated one month following radiotherapy. Mean middle and inferior pharyngeal dose was recorded and correlated with the MBS results to determine aspiration risk.


Scanning In Situ Spectroscopy Pplatform For Imaging Surgical Breast Tissue Specimens, Venkataramanan Krishnaswamy, Ashley M. Laughney, Wendy A. Wells, Keith D. Paulsen, Brian W. Pogue Jan 2013

Scanning In Situ Spectroscopy Pplatform For Imaging Surgical Breast Tissue Specimens, Venkataramanan Krishnaswamy, Ashley M. Laughney, Wendy A. Wells, Keith D. Paulsen, Brian W. Pogue

Dartmouth Scholarship

A non-contact localized spectroscopic imaging platform has been developed and optimized to scan 1 x 1 cm² square regions of surgically resected breast tissue specimens with ~150-micron resolution. A color corrected, image-space telecentric scanning design maintained a consistent sampling geometry and uniform spot size across the entire imaging field. Theoretical modeling in ZEMAX allowed estimation of the spot size, which is equal at both the center and extreme positions of the field with ~5% variation across the designed waveband, indicating excellent color correction. The spot sizes at the center and an extreme field position were also measured experimentally using the …