Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 10 of 10

Full-Text Articles in Medicine and Health Sciences

Hybrid Photomultiplier Tube And Photodiode Parallel Detection Array For Wideband Optical Spectroscopy Of The Breast Guided By Magnetic Resonance Imaging, Fadi El-Ghussein, Michael A. Mastanduno, Shudong Jiang, Brian W. Pogue, Keith D. Paulsen Aug 2014

Hybrid Photomultiplier Tube And Photodiode Parallel Detection Array For Wideband Optical Spectroscopy Of The Breast Guided By Magnetic Resonance Imaging, Fadi El-Ghussein, Michael A. Mastanduno, Shudong Jiang, Brian W. Pogue, Keith D. Paulsen

Dartmouth Scholarship

A new optical parallel detection system of hybrid frequency and continuous-wave domains was developed to improve the data quality and accuracy in recovery of all breast optical properties. This new system was deployed in a previously existing system for magnetic resonance imaging (MRI)-guided spectroscopy, and allows incorporation of additional near-infrared wavelengths beyond 850 nm, with interlaced channels of photomultiplier tubes (PMTs) and silicon photodiodes (PDs). The acquisition time for obtaining frequency-domain data at six wavelengths (660, 735, 785, 808, 826, and 849 nm) and continuous-wave data at three wavelengths (903, 912, and 948 nm) is 12 min. The dynamic ranges …


Sensitivity Of Mri-Guided Near-Infrared Spectroscopy Clinical Breast Exam Data And Its Impact On Diagnostic Performance, Michael A. Mastanduno, Junqing Xu, Fadi El-Ghussein, Shudong Jiang, Hong Yin, Yan Zhao, Kelly E. Michaelson, Ke Wang, Fang Ren, Brian W. Pogue, Keith D. Paulsen Aug 2014

Sensitivity Of Mri-Guided Near-Infrared Spectroscopy Clinical Breast Exam Data And Its Impact On Diagnostic Performance, Michael A. Mastanduno, Junqing Xu, Fadi El-Ghussein, Shudong Jiang, Hong Yin, Yan Zhao, Kelly E. Michaelson, Ke Wang, Fang Ren, Brian W. Pogue, Keith D. Paulsen

Dartmouth Scholarship

In this study, data from breast MRI-guided near infrared spectroscopy (NIRS) exams delivered to 44 patients scheduled for surgical resection (ending in 16 benign and 28 malignant diagnoses) were analyzed using a spatial sensitivity metric to quantify the adequacy of the optical measurements for interrogating the tumor region of interest, as derived from the concurrent MRI scan. Along with positional sensitivity, the incorporation of spectral priors and the selection of an appropriate regularization parameter in the image reconstruction were considered, and found to influence the diagnostic accuracy of the recovered images. Once optimized, the MRI/NIRS data was able to differentiate …


Structured Light Scatteroscopy, Venkataramanan Krishnaswamy, Jonathan T. Elliott, David M. Mcclatchy, Richard J. Barth Jr., Wendy A. Wells, Brian W. Pogue, Keith D. Paulsen Jul 2014

Structured Light Scatteroscopy, Venkataramanan Krishnaswamy, Jonathan T. Elliott, David M. Mcclatchy, Richard J. Barth Jr., Wendy A. Wells, Brian W. Pogue, Keith D. Paulsen

Dartmouth Scholarship

A new imaging approach, structured light scatteroscopy (SLS), is demonstrated, which offers rapid wide-field imaging of microscopic morphological variations in bulk tissue surfaces. Elastic scattering of light offers exquisite sensitivity to ultrastructural changes at multiple size scales ranging from nanometers to millimeters, but in bulk tissues the confounding effects of molecular absorption and strong multiple scattering of light often lead to a dramatic reduction in scatter contrast and specificity. It is demonstrated that the SLS using structured high spatial frequency illumination and detection to probe the tissue achieves direct, absorption-independent, high-resolution maps of the scattering response. The scattering response is …


Comparison Of Magnetic Resonance Imaging-Compatible Optical Detectors For In-Magnet Tissue Spectroscopy: Photodiodes Versus Silicon Photomultipliers, Fadi El-Ghussein, Shudong Jiang, Brian W. Pogue, Keith D. Paulsen, Brian W. Pogue Jul 2014

Comparison Of Magnetic Resonance Imaging-Compatible Optical Detectors For In-Magnet Tissue Spectroscopy: Photodiodes Versus Silicon Photomultipliers, Fadi El-Ghussein, Shudong Jiang, Brian W. Pogue, Keith D. Paulsen, Brian W. Pogue

Dartmouth Scholarship

Tissue spectroscopy inside the magnetic resonance imaging (MRI) system adds a significant value by measuring fast vascular hemoglobin responses or completing spectroscopic identification of diagnostically relevant molecules. Advances in this type of spectroscopy instrumentation have largely focused on fiber coupling into and out of the MRI; however, nonmagnetic detectors can now be placed inside the scanner with signal amplification performed remotely to the high field environment for optimized light detection. In this study, the two possible detector options, such as silicon photodiodes (PD) and silicon photomultipliers (SiPM), were systematically examined for dynamic range and wavelength performance. Results show that PDs …


Dual-Channel Red/Blue Fluorescence Dosimetry With Broadband Reflectance Spectroscopic Correction Measures Protoporphyrin Ix Production During Photodynamic Therapy Of Actinic Keratosis, Stephen Chad Kanick, Scott C. Davis, Yan Zhao, Tayyaba Hasan, Edward V. Maytin, Brian W. Pogue, M Shane Chapman Jul 2014

Dual-Channel Red/Blue Fluorescence Dosimetry With Broadband Reflectance Spectroscopic Correction Measures Protoporphyrin Ix Production During Photodynamic Therapy Of Actinic Keratosis, Stephen Chad Kanick, Scott C. Davis, Yan Zhao, Tayyaba Hasan, Edward V. Maytin, Brian W. Pogue, M Shane Chapman

Dartmouth Scholarship

Dosimetry for aminolevulinic acid (ALA)-induced protoporphyrin IX (PpIX) photodynamic therapy of actinic keratosis was examined with an optimized fluorescence dosimeter to measure PpIX during treatment. While insufficient PpIX generation may be an indicator of incomplete response, there exists no standardized method to quantitate PpIX production at depths in the skin during clinical treatments. In this study, a spectrometer-based point probe dosimeter system was used to sample PpIX fluorescence from superficial (blue wavelength excitation) and deeper (red wavelength excitation) tissue layers. Broadband white light spectroscopy (WLS) was used to monitor aspects of vascular physiology and inform a correction of fluorescence for …


Extraction Of Intrinsic Fluorescence From Single Fiber Fluorescence Measurements On A Turbid Medium: Experimental Validation, U. A. Gamm, C. L. Hoy, F. Van Leeuwen - Van Zaane, H. J. C. M. Sterenborg, S. C. Kanick, D J. Robinson, A. Amelink May 2014

Extraction Of Intrinsic Fluorescence From Single Fiber Fluorescence Measurements On A Turbid Medium: Experimental Validation, U. A. Gamm, C. L. Hoy, F. Van Leeuwen - Van Zaane, H. J. C. M. Sterenborg, S. C. Kanick, D J. Robinson, A. Amelink

Dartmouth Scholarship

Abstract

The detailed mechanisms associated with the influence of scattering and absorption properties on the fluorescence intensity sampled by a single optical fiber have recently been elucidated based on Monte Carlo simulated data. Here we develop an experimental single fiber fluorescence (SFF) spectroscopy setup and validate the Monte Carlo data and semi-empirical model equation that describes the SFF signal as a function of scattering. We present a calibration procedure that corrects the SFF signal for all system-related, wavelength dependent transmission efficiencies to yield an absolute value of intrinsic fluorescence. The validity of the Monte Carlo data and semi-empirical model is …


Anthropomorphic Breast Phantoms With Physiological Water, Lipid, And Hemoglobin Content For Near-Infrared Spectral Tomography, Kelly E. Michaelsen, Venkataramanan Krishnaswamy, Adele Shenoy, Emily Jordan, Brian W. Pogue, Keith D. Paulsen Feb 2014

Anthropomorphic Breast Phantoms With Physiological Water, Lipid, And Hemoglobin Content For Near-Infrared Spectral Tomography, Kelly E. Michaelsen, Venkataramanan Krishnaswamy, Adele Shenoy, Emily Jordan, Brian W. Pogue, Keith D. Paulsen

Dartmouth Scholarship

Breast mimicking tissue optical phantoms with sufficient structural integrity to be deployed as stand-alone imaging targets are developed and successfully constructed with biologically relevant concentrations of water, lipid, and blood. The results show excellent material homogeneity and reproducibility with inter- and intraphantom variability of 3.5 and 3.8%, respectively, for water and lipid concentrations ranging from 15 to 85%. The phantoms were long-lasting and exhibited water and lipid fractions that were consistent to within 5% of their original content when measured 2 weeks after creation. A breast-shaped three-compartment model of adipose, fibroglandular, and malignant tissues was created with water content ranging …


Advances In Optics For Biotechnology, Medicine And Surgery, Maryann Fitzmaurice, Brian W. Pogue, Guillermo J. Tearney, James W. Tunnell Jan 2014

Advances In Optics For Biotechnology, Medicine And Surgery, Maryann Fitzmaurice, Brian W. Pogue, Guillermo J. Tearney, James W. Tunnell

Dartmouth Scholarship

The guest editors introduce a Biomedical Optics Express feature issue that includes contributions from participants at the 2013 conference on Advances in Optics for Biotechnology, Medicine and Surgery XIII.


An Imaging-Based Platform For High-Content, Quantitative Evaluation Of Therapeutic Response In 3d Tumour Models, Jonathan P. Celli, Imran Rizvi, Adam R. Blanden, Iqbal Massodi, Iqbal Massodi, Michael D. Glidden, Brian Pogue, Tayyaba Hasan Jan 2014

An Imaging-Based Platform For High-Content, Quantitative Evaluation Of Therapeutic Response In 3d Tumour Models, Jonathan P. Celli, Imran Rizvi, Adam R. Blanden, Iqbal Massodi, Iqbal Massodi, Michael D. Glidden, Brian Pogue, Tayyaba Hasan

Dartmouth Scholarship

While it is increasingly recognized that three-dimensional (3D) cell culture models recapitulate drug responses of human cancers with more fidelity than monolayer cultures, a lack of quantitative analysis methods limit their implementation for reliable and routine assessment of emerging therapies. Here, we introduce an approach based on computational analysis of fluorescence image data to provide high-content readouts of dose-dependent cytotoxicity, growth inhibition, treatment-induced architectural changes and size-dependent response in 3D tumour models. We demonstrate this approach in adherent 3D ovarian and pancreatic multiwell extracellular matrix tumour overlays subjected to a panel of clinically relevant cytotoxic modalities and appropriately designed controls …


Spatial Frequency Analysis Of Anisotropic Drug Transport In Tumor Samples, Stewart Russell, Kimberley S. Samkoe, Jason R. Gunn, P Jack Hoopes, Thienan A. Nguyen, Milo J. Russell, Robert R. Alfano, Brian W. Pogue Jan 2014

Spatial Frequency Analysis Of Anisotropic Drug Transport In Tumor Samples, Stewart Russell, Kimberley S. Samkoe, Jason R. Gunn, P Jack Hoopes, Thienan A. Nguyen, Milo J. Russell, Robert R. Alfano, Brian W. Pogue

Dartmouth Scholarship

Directional Fourier spatial frequency analysis was used on standard histological sections to identify salient directional bias in the spatial frequencies of stromal and epithelial patterns within tumor tissue. This directional bias is shown to be correlated to the pathway of reduced fluorescent tracer transport. Optical images of tumor specimens contain a complex distribution of randomly oriented aperiodic features used for neoplastic grading that varies with tumor type, size, and morphology. The internal organization of these patterns in frequency space is shown to provide a precise fingerprint of the extracellular matrix complexity, which is well known to be related to the …