Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 7 of 7

Full-Text Articles in Medicine and Health Sciences

Impact Of Feeding Tube Status On Health Outcomes For Individuals With Oropharyngeal Cancer, Nedeljko Jovanovic Aug 2018

Impact Of Feeding Tube Status On Health Outcomes For Individuals With Oropharyngeal Cancer, Nedeljko Jovanovic

Electronic Thesis and Dissertation Repository

Abstract

This study investigated differences in outcomes related to health, swallowing, and quality of life (QoL) for individuals with oropharyngeal squamous cell carcinoma (OPSCC) receiving either radiotherapy (RT) alone, or concomitant chemoradiotherapy (CRT). Differences were assessed based on whether patients received a feeding tube (FT group) or not (NFT group). Measures including the Functional Oral Intake Scale (FOIS), Performance Status Scale for Head and Neck Cancer (PSS-HN), M.D. Anderson Dysphagia Inventory (MDADI), and weight were collected for 126 individuals at baseline, and at 3, 6, and 12 months post-treatment. Data were analyzed to identify potential prognostic differences between the groups, …


Accuracy Requirements And Uncertainties In Radiotherapy: A Report Of The International Atomic Energy Agency., Debbie Van Der Merwe, Jacob Van Dyk, Brendan Healy, Eduardo Zubizarreta, Joanna Izewska, Ben Mijnheer, Ahmed Meghzifene Nov 2016

Accuracy Requirements And Uncertainties In Radiotherapy: A Report Of The International Atomic Energy Agency., Debbie Van Der Merwe, Jacob Van Dyk, Brendan Healy, Eduardo Zubizarreta, Joanna Izewska, Ben Mijnheer, Ahmed Meghzifene

Oncology Publications

BACKGROUND: Radiotherapy technology continues to advance and the expectation of improved outcomes requires greater accuracy in various radiotherapy steps. Different factors affect the overall accuracy of dose delivery. Institutional comprehensive quality assurance (QA) programs should ensure that uncertainties are maintained at acceptable levels. The International Atomic Energy Agency has recently developed a report summarizing the accuracy achievable and the suggested action levels, for each step in the radiotherapy process. Overview of the report: The report seeks to promote awareness and encourage quantification of uncertainties in order to promote safer and more effective patient treatments. The radiotherapy process and the radiobiological …


Non-Invasive Imaging For The Assessment Of Cardiac Dose And Function Following Focused External Beam Irradiation, Omar El-Sherif Jun 2016

Non-Invasive Imaging For The Assessment Of Cardiac Dose And Function Following Focused External Beam Irradiation, Omar El-Sherif

Electronic Thesis and Dissertation Repository

Technological advances in imaging and radiotherapy have led to significant improvement in the survival rate of breast cancer patients. However, a larger proportion of patients are now exhibiting the less understood, latent effects of incidental cardiac irradiation that occurs during left-sided breast radiotherapy. Here, we examine the utility of four-dimensional computed tomography (4D-CT) for the accurate assessment of cardiac dose; and a hybrid positron emission tomography (PET) magnetic resonance imaging (MRI) system to longitudinally study radiation-induced cardiac effects in a canine model.

Using 4D-CT and deformable dose accumulation, we assessed the variation caused by breathing motion in the estimated dose …


Strategies For Reducing The Impact Of Tumour Motion During Helical Tomotherapy, Bryan Kim Aug 2011

Strategies For Reducing The Impact Of Tumour Motion During Helical Tomotherapy, Bryan Kim

Electronic Thesis and Dissertation Repository

Tumour motion presents a significant limitation for effective radiotherapy of lung cancer, and more specifically for helical tomotherapy. The simultaneous and continuous movements of tomotherapy subsystems (gantry, couch, and binary multi-leaf collimator) can lead to inaccurate dose delivery, when combined with tumour motion. In this thesis, we have investigated the impact of tumour motion and strategies to reduce the resulting dose discrepancies for helical tomotherapy, through computer simulations and film measurements performed in a dynamic body phantom. Three distinctively different types of dose discrepancies have been isolated: dose rounding, dose rippling, and the intensity-modulated radiation therapy (IMRT) asynchronization effect. Each …


Adaptive Radiation Therapy For Localized Mesothelioma With Mediastinal Metastasis Using Helical Tomotherapy., James Renaud, Slav Yartsev, A Rashid Dar, Jacob Van Dyk Jan 2009

Adaptive Radiation Therapy For Localized Mesothelioma With Mediastinal Metastasis Using Helical Tomotherapy., James Renaud, Slav Yartsev, A Rashid Dar, Jacob Van Dyk

Oncology Publications

The purpose of this study was to compare 2 adaptive radiotherapy strategies with helical tomotherapy. A patient having mesothelioma with mediastinal nodes was treated using helical tomotherapy with pretreatment megavoltage CT (MVCT) imaging. Gross tumor volumes (GTVs) were outlined on every MVCT study. Two alternatives for adapting the treatment were investigated: (1) keeping the prescribed dose to the targets while reducing the dose to the OARs and (2) escalating the target dose while maintaining the original level of healthy tissue sparing. Intensity modulated radiotherapy (step-and-shoot IMRT) and 3D conformal radiotherapy (3DCRT) plans for the patient were generated and compared. The …


Consistency Check Of Planned Adaptive Option On Helical Tomotherapy., M Schirm, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk Dec 2008

Consistency Check Of Planned Adaptive Option On Helical Tomotherapy., M Schirm, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk

Oncology Publications

This study aims to evaluate a new Planned Adaptive software (TomoTherapy Inc., Madison, WI) of the helical tomotherapy system by retrospective verification and adaptive re-planning of radiation treatment. Four patients with different disease sites (brain, nasal cavity, lungs, prostate) were planned in duplicate using the diagnostic planning kVCT data set and MVCT studies of the first treatment fraction with the same optimization parameters for both plan types. The dosimetric characteristics of minimum, maximum, and mean dose to the targets as well as to organs at risk were compared. Both sets of plans were used for calculation of dose distributions in …


Quality Assurance Of Radiation Therapy Planning Systems: Current Status And Remaining Challenges., Jacob Van Dyk May 2008

Quality Assurance Of Radiation Therapy Planning Systems: Current Status And Remaining Challenges., Jacob Van Dyk

Oncology Publications

Computerized radiation therapy planning systems (RTPSs) are pivotal for treatment planning. The acceptance, commissioning, and quality control of RTPSs are uniquely complex and are described in the American Association of Physicists in Medicine Task Group Report 53 (1998) and International Atomic Energy Agency Technical Report Series No. 430 (2004). The International Atomic Energy Agency also developed a document and data package for use by vendors and purchasers to aid with acceptance testing of RTPSs. This document is based on International Electrotechnical Commission standard 62083 (2000) and describes both "type" tests to be performed in the factory and "site" tests to …