Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

University of Nebraska - Lincoln

2012

Health Information Technology

Biomedical Imaging and Biosignal Analysis Laboratory

Articles 1 - 3 of 3

Full-Text Articles in Medicine and Health Sciences

Flowcell Systems For Single Molecule Detection, John G. K. Williams, Gregory R. Bashford, Jiyan Chen, Dan Draney, Nara Narayanan, Bambi L. Reynolds, Pamela Sheaff Apr 2012

Flowcell Systems For Single Molecule Detection, John G. K. Williams, Gregory R. Bashford, Jiyan Chen, Dan Draney, Nara Narayanan, Bambi L. Reynolds, Pamela Sheaff

Biomedical Imaging and Biosignal Analysis Laboratory

The present invention provides compounds, methods and systems for sequencing nucleic acid using single molecule detection. Using labeled NPs that exhibit charge-switching behavior, single-molecule DNA sequencing in a microchannel sorting system is realized. In operation, sequencing products are detected enabling real-time sequencing as successive detectable moieties flow through a detection channel. By electrically sorting charged molecules, the cleaved product molecules are detected in isolation without interference from unincorporated NPs and without illuminating the polymerase-DNA complex.


Two-Dimensional Blood Flow Velocity Estimation Using Apparent Speckle Pattern Angle Dependence On Scan Velocity, Tiantian Xu, Gregory R. Bashford Jan 2012

Two-Dimensional Blood Flow Velocity Estimation Using Apparent Speckle Pattern Angle Dependence On Scan Velocity, Tiantian Xu, Gregory R. Bashford

Biomedical Imaging and Biosignal Analysis Laboratory

An algorithm which measures the lateral component of blood flow velocity was developed in our previous studies based on the increase in speckle size due to relative motion between moving scatterers and spatial rate of scanner A-line acquisition (scan velocity). In this paper, the apparent dominant angle of the speckle pattern in a straight vessel was investigated and a new method of two-dimensional blood flow velocity estimation is introduced. Different scan velocities were used for data acquisition from blood flow traveling at an angle relative to the ultrasound beam. The apparent angle of the speckle pattern changes with different scan …


Monitoring Cerebral Hemodynamics With Transcranial Doppler Ultrasound During Cognitive And Exercise Testing In Adults Following Unilateral Stroke, Brian P. Watt, Judith M. Burnfield, Edward J. Truemper, Thad W. Buster, Gregory R. Bashford Jan 2012

Monitoring Cerebral Hemodynamics With Transcranial Doppler Ultrasound During Cognitive And Exercise Testing In Adults Following Unilateral Stroke, Brian P. Watt, Judith M. Burnfield, Edward J. Truemper, Thad W. Buster, Gregory R. Bashford

Biomedical Imaging and Biosignal Analysis Laboratory

An observational study was performed as a preliminary investigation into the use of transcranial Doppler ultrasound (TCD) for recording cerebral hemodynamic changes during multiple tasks. TCD is a method of measuring cerebral blood flow (CBF) using ultrasound transducers in contact with the surface of the head. Using the maximum flow envelope of the Doppler spectrum returning from the middle cerebral artery (MCA), standard clinical flow indices can be calculated and displayed in real time providing information concerning perturbations in CBF and their potential cause. These indices as well as flow velocity measurements have been recognized as useful in measuring changes …