Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 6 of 6

Full-Text Articles in Medicine and Health Sciences

Lpcoms: Towards A Low Power Wireless Smart-Shoe System For Gait Analysis In People With Disabilities, Ishmat Zerin Oct 2015

Lpcoms: Towards A Low Power Wireless Smart-Shoe System For Gait Analysis In People With Disabilities, Ishmat Zerin

Master's Theses (2009 -)

Gait analysis using smart sensor technology is an important medical diagnostic process and has many applications in rehabilitation, therapy and exercise training. In this thesis, we present a low power wireless smart-shoe system (LPcomS) to analyze different functional postures and characteristics of gait while walking. We have designed and implemented a smart-shoe with a Bluetooth communication module to unobtrusively collect data using smartphone in any environment. With the design of a shoe insole equipped with four pressure sensors, the foot pressure is been collected, and those data are used to obtain accurate gait pattern of a patient. With our proposed …


Integrating Meal And Exercise Into Personalized Glucoregulation Models: Metabolic Dynamics And Diabetic Athletes, Sofie Schunk Oct 2015

Integrating Meal And Exercise Into Personalized Glucoregulation Models: Metabolic Dynamics And Diabetic Athletes, Sofie Schunk

Master's Theses (2009 -)

Diabetes affects nearly 26 million Americans, according to the American Diabetes Association, with as many as three million Americans who have Type 1 Diabetes (ADA, 2015). Type 1 Diabetes (T1D) is autoimmune and characterized by little to no insulin production whereas Type 2 Diabetes (T2D) concerns insulin resistance and inability to use produced insulin. Factors contributing to current diabetes management and regulation include exercise type, daily movement activities, and distinct tissue compartment metabolism, each challenging to model in a robust and comprehensive manner. Past models are highly limited in regard to exercise and varying glucose fluctuations dependent on type, intensity, …


Impaired Regulation Post-Stroke Of Motor Unit Firing Behavior During Volitional Relaxation Of Knee Extensor Torque Assessed Using High Density Surface Emg Decomposition, Spencer A. Murphy, Reivian Berrios, P. Andrew Nelson, Francesco Negro, Dario Farina, Brian D. Schmit, Allison Hyngstrom Aug 2015

Impaired Regulation Post-Stroke Of Motor Unit Firing Behavior During Volitional Relaxation Of Knee Extensor Torque Assessed Using High Density Surface Emg Decomposition, Spencer A. Murphy, Reivian Berrios, P. Andrew Nelson, Francesco Negro, Dario Farina, Brian D. Schmit, Allison Hyngstrom

Physical Therapy Faculty Research and Publications

The purpose of this study was to use high density surface EMG recordings to quantify stroke-related abnormalities in motor unit firing behavior during repeated sub-maximal knee extensor contractions. A high density surface EMG system (sEMG) was used to record and extract single motor unit firing behavior in the vastus lateralis muscle of 6 individuals with chronic stroke and 8 controls during repeated sub-maximal isometric knee extension contractions. Paretic motor unit firing rates were increased with subsequent contractions (6.19±0.35 pps vs 7.89±0.66 pps, P


Stroke-Related Effects On Maximal Dynamic Hip Flexor Fatigability And Functional Implications, Henry Kuhnen, Megan M. Rybar, Tanya Onushko, Ryan E. Doyel, Sandra K. Hunter, Brian D. Schmit, Allison Hyngstrom Mar 2015

Stroke-Related Effects On Maximal Dynamic Hip Flexor Fatigability And Functional Implications, Henry Kuhnen, Megan M. Rybar, Tanya Onushko, Ryan E. Doyel, Sandra K. Hunter, Brian D. Schmit, Allison Hyngstrom

Exercise Science Faculty Research and Publications

Introduction: Stroke-related changes in maximal dynamic hip flexor muscle fatigability may be more relevant functionally than isometric hip flexor fatigability. Methods: Ten chronic stroke survivors performed 5 sets of 30 hip flexion maximal dynamic voluntary contractions (MDVC). A maximal isometric voluntary contraction (MIVC) was performed before and after completion of the dynamic contractions. Both the paretic and nonparetic legs were tested. Results: Reduction in hip flexion MDVC torque in the paretic leg (44.7%) was larger than the nonparetic leg (31.7%). The paretic leg had a larger reduction in rectus femoris EMG (28.9%) between the first and last …


A Novel Fmri Paradigm Suggests That Pedaling-Related Brain Activation Is Altered After Stroke, Nutta-On Promjunyakul, Brian D. Schmit, Sheila M. Schindler-Ivens Jan 2015

A Novel Fmri Paradigm Suggests That Pedaling-Related Brain Activation Is Altered After Stroke, Nutta-On Promjunyakul, Brian D. Schmit, Sheila M. Schindler-Ivens

Physical Therapy Faculty Research and Publications

The purpose of this study was to examine the feasibility of using functional magnetic resonance imaging (fMRI) to measure pedaling-related brain activation in individuals with stroke and age-matched controls. We also sought to identify stroke-related changes in brain activation associated with pedaling. Fourteen stroke and 12 control subjects were asked to pedal a custom, MRI-compatible device during fMRI. Subjects also performed lower limb tapping to localize brain regions involved in lower limb movement. All stroke and control subjects were able to pedal while positioned for fMRI. Two control subjects were withdrawn due to claustrophobia, and one control data set was …


Evaluation Of Pediatric Manual Wheelchair Mobility Using Advanced Biomechanical Methods, Brooke A. Slavens, Alyssa J. Schnorenberg, Christine M. Aurit, Adam Graf, Joseph J. Krzak, Kathryn Reiners, Lawrence C. Vogel, Gerald F. Harris Jan 2015

Evaluation Of Pediatric Manual Wheelchair Mobility Using Advanced Biomechanical Methods, Brooke A. Slavens, Alyssa J. Schnorenberg, Christine M. Aurit, Adam Graf, Joseph J. Krzak, Kathryn Reiners, Lawrence C. Vogel, Gerald F. Harris

Biomedical Engineering Faculty Research and Publications

There is minimal research of upper extremity joint dynamics during pediatric wheelchair mobility despite the large number of children using manual wheelchairs. Special concern arises with the pediatric population, particularly in regard to the longer duration of wheelchair use, joint integrity, participation and community integration, and transitional care into adulthood. This study seeks to provide evaluation methods for characterizing the biomechanics of wheelchair use by children with spinal cord injury (SCI). Twelve subjects with SCI underwent motion analysis while they propelled their wheelchair at a self-selected speed and propulsion pattern. Upper extremity joint kinematics, forces, and moments were computed using …