Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 4 of 4
Full-Text Articles in Medicine and Health Sciences
Bdnf In The Dentate Gyrus Is Required For Consolidation Of "Pattern-Separated" Memories., Pedro Bekinschtein, Brianne A Kent, Charlotte A Oomen, Gregory D Clemenson, Fred H Gage, Lisa M Saksida, Timothy J Bussey
Bdnf In The Dentate Gyrus Is Required For Consolidation Of "Pattern-Separated" Memories., Pedro Bekinschtein, Brianne A Kent, Charlotte A Oomen, Gregory D Clemenson, Fred H Gage, Lisa M Saksida, Timothy J Bussey
Brain and Mind Institute Researchers' Publications
Successful memory involves not only remembering information over time, but also keeping memories distinct and less confusable. The computational process for making representations for similar input patterns more distinct from each other has been referred to as "pattern separation." In this work, we developed a set of behavioral conditions that allowed us to manipulate the load for pattern separation at different stages of memory. Thus, we provide experimental evidence that a brain-derived neurotrophic factor (BDNF)-dependent pattern separation process occurs during the encoding/storage/consolidation, but not the retrieval stage of memory processing. We also found that a spontaneous increase in BDNF in …
The Touchscreen Operant Platform For Testing Working Memory And Pattern Separation In Rats And Mice., Charlotte A Oomen, Martha Hvoslef-Eide, Christopher J Heath, Adam C Mar, Alexa E Horner, Timothy J Bussey, Lisa M Saksida
The Touchscreen Operant Platform For Testing Working Memory And Pattern Separation In Rats And Mice., Charlotte A Oomen, Martha Hvoslef-Eide, Christopher J Heath, Adam C Mar, Alexa E Horner, Timothy J Bussey, Lisa M Saksida
Brain and Mind Institute Researchers' Publications
The automated touchscreen operant chamber for rats and mice allows for the assessment of multiple cognitive domains within the same testing environment. This protocol presents the location discrimination (LD) task and the trial-unique delayed nonmatching-to-location (TUNL) task, which both assess memory for location. During these tasks, animals are trained to a predefined criterion during ∼20-40 daily sessions. In LD sessions, touching the same location on the screen is rewarded on consecutive trials, followed by a reversal of location-reward contingencies. TUNL, a working memory task, requires animals to 'nonmatch' to a sample location after a delay. In both the LD and …
Acute Alcohol Consumption Impairs Controlled But Not Automatic Processes In A Psychophysical Pointing Paradigm., Kevin Johnston, Brian Timney, Melvyn A Goodale
Acute Alcohol Consumption Impairs Controlled But Not Automatic Processes In A Psychophysical Pointing Paradigm., Kevin Johnston, Brian Timney, Melvyn A Goodale
Brain and Mind Institute Researchers' Publications
Numerous studies have investigated the effects of alcohol consumption on controlled and automatic cognitive processes. Such studies have shown that alcohol impairs performance on tasks requiring conscious, intentional control, while leaving automatic performance relatively intact. Here, we sought to extend these findings to aspects of visuomotor control by investigating the effects of alcohol in a visuomotor pointing paradigm that allowed us to separate the influence of controlled and automatic processes. Six male participants were assigned to an experimental "correction" condition in which they were instructed to point at a visual target as quickly and accurately as possible. On a small …
Errors In Device Localization In Mri Using Z-Frames., Jeremy Cepek, Blaine A Chronik, Aaron Fenster
Errors In Device Localization In Mri Using Z-Frames., Jeremy Cepek, Blaine A Chronik, Aaron Fenster
Brain and Mind Institute Researchers' Publications
The use of a passive MRI-visible tracking frame is a common method of localizing devices in MRI space for MRI-guided procedures. One of the most common tracking frame designs found in the literature is the z-frame, as it allows six degree-of-freedom pose estimation using only a single image slice. Despite the popularity of this design, it is susceptible to errors in pose estimation due to various image distortion mechanisms in MRI. In this paper, the absolute error in using a z-frame to localize a tool in MRI is quantified over various positions of the z-frame relative to the MRI isocenter, …