Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

PDF

Marquette University

Master's Theses (2009 -)

Implants

Articles 1 - 4 of 4

Full-Text Articles in Medicine and Health Sciences

Influence Of Free-End Distal Extension On The Accuracy Of Guided Implant Placement: An In Vitro Study, Geoffrey Ganzman Apr 2022

Influence Of Free-End Distal Extension On The Accuracy Of Guided Implant Placement: An In Vitro Study, Geoffrey Ganzman

Master's Theses (2009 -)

Purpose: The aim of this study was to evaluate the influence of type of tooth-support (bounded edentulous space versus unbounded edentulous spaces) on the accuracy of fully-guided implant placement using static computer-assisted implant surgery (sCAIS) in partially-dentate patients. Methods: Four different clinical scenarios were simulated; (a) bounded single-tooth edentulous space (BES), and three different free-end distal extensions with (b) unbounded single-tooth edentulous space (UBES1), (c) unbounded two-teeth edentulous space (UBES2), and (d) unbounded three-teeth edentulous space (UBES3). An implant planning software was used to design 3D-printed stereolithographic surgical guides for the respective clinical scenarios. In total n=140 implants with dimensions …


Peri-Implantitis Risk Prediction Using A Computer Based Periodontal Risk Calculator Tool: A Retrospective Study, Walaa Al Zaibak Apr 2020

Peri-Implantitis Risk Prediction Using A Computer Based Periodontal Risk Calculator Tool: A Retrospective Study, Walaa Al Zaibak

Master's Theses (2009 -)

Introduction: Although literature is abundant on the diagnosis and management of peri-implantitis after it has occurred, to our current knowledge there are no studies that have specifically looked into the relationship between peri-implantitis and the periodontal risk assessment tool used for natural dentitions.Material and Methods: In this retrospective study, the patient population included patients (>20 years of age) who had implants placed and restored at Marquette University School of Dentistry (MUSOD) from 2008 to 2016. Further, the restored implants in these patients must have been in function for at least one year and followed up in the school …


Evaluation Of Accuracy Of Static Computer-Guided Implant Placement Compared With Partially-Guided Or Free-Hand Placement, Laxmi Sukhtankar Apr 2019

Evaluation Of Accuracy Of Static Computer-Guided Implant Placement Compared With Partially-Guided Or Free-Hand Placement, Laxmi Sukhtankar

Master's Theses (2009 -)

Purpose: To evaluate precision and trueness of static computer-assisted implant surgery (sCAIS) in comparison with partially-guided and free-hand implant placement in vitro.Materials & Methods: The study was conducted on one hundred mandible replicas obtained from a cone beam computer tomography of a partially edentulous case for implant placement in mandibular right first molar site. First, the fully guided implant placement with different sleeve to bone distances (2mm = H2, 4mm = H4, 6mm= H6) was determined. Second, fully guided implant placement was compared with partially guided, and free implant placement. The achieved implant position was digitized and compared …


Comparing The Vertical Misfit Of Casts Produced By Two Verification Jigs, Abdulaziz Saeed Alqahtani Jul 2014

Comparing The Vertical Misfit Of Casts Produced By Two Verification Jigs, Abdulaziz Saeed Alqahtani

Master's Theses (2009 -)

Purpose: To compare the dimensional accuracy between master casts fabricated with verification jigs made of acrylic resin and light cure Triad. Materials and Methods: 10 GC Pattern resin Pattern verifications jigs and 10 Triad gel verification jigs fabricated of a master cast of a mandibular model of 4 internal hex implants. A stone base was fabricated for each verification jig. One screw test was used to evaluate the vertical gap at the terminal abutment using a digital micrometer with an accuracy of 1μm to record the vertical gap for each sample. Results: Triad Gel group has the lowest average distortion …