Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Speech and Hearing Science

PDF

Electronic Thesis and Dissertation Repository

Theses/Dissertations

Sound localization

Publication Year

Articles 1 - 3 of 3

Full-Text Articles in Medicine and Health Sciences

Behavioural And Objective Assessment Of Binaural Hearing In Adult Listeners With Acquired Unilateral Conductive Hearing Loss Before And After Middle Ear Surgery, Parvaneh Abbasalipour Nov 2019

Behavioural And Objective Assessment Of Binaural Hearing In Adult Listeners With Acquired Unilateral Conductive Hearing Loss Before And After Middle Ear Surgery, Parvaneh Abbasalipour

Electronic Thesis and Dissertation Repository

In normally hearing listeners, binaural hearing relies on symmetrical input from the two ears. Previous studies on human listeners have assessed the effect of induced unilateral conductive hearing loss (UCHL) during adulthood via earplugging. These experiments indicated initial difficulty in sound localization followed by gradual improvement due to adaptation to the perturbed binaural cues. The limited duration of earplug use does not represent the consequences of chronic UCHL secondary to disease. Furthermore, there is insufficient information regarding the adaptation of binaural hearing abilities after treatment of late-onset UCHL.

The current study assessed the binaural hearing abilities of adult listeners with …


The Effects Of Target Spectrum, Noise, And Reverberation On Auditory Cue Weighting In Sound Localization, Tran M. Nguyen Aug 2014

The Effects Of Target Spectrum, Noise, And Reverberation On Auditory Cue Weighting In Sound Localization, Tran M. Nguyen

Electronic Thesis and Dissertation Repository

Sound localization in the horizontal plane depends on interaural time difference (ITD) and interaural level difference (ILD) cues, which are both available in wideband sounds. Previous studies have directly measured listener weighting of those cues only under quiet, anechoic conditions, but not in the presence of noise and reverberation, which can degrade both ITD and ILD. This study examined the effects of changes in target spectral profile, background noise, and reverberation on sound localization performance and cue weighting strategies. Listeners reported locations of targets that were presented over headphones in virtual auditory space. ITD and ILD were manipulated by attenuating …


Effect Of Head Movement On Sound Localization In Real And Simulated Cochlear Implant Users, Kassandra-Anne H. Birtch Jul 2012

Effect Of Head Movement On Sound Localization In Real And Simulated Cochlear Implant Users, Kassandra-Anne H. Birtch

Electronic Thesis and Dissertation Repository

Cochlear implant (CI) users’ limited ability to use acoustical cues for sound localization causes left/right confusions and front/back reversals. Head movement is beneficial in reducing these errors in acoustically hearing listeners. This study investigated the effect of head movement on localization throughout 360o of azimuth for both real and simulated CI users. Listeners in a bilateral electro-acoustic (CI with ipsilateral hearing aid) simulation derived the greatest head movement benefit in reducing front/back reversals. Left/right confusions were reduced in simulations with matched bilateral stimulation. Sensitivity to both timing and level cues for sound localization was correlated with sound localization performance without …