Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 9 of 9

Full-Text Articles in Medicine and Health Sciences

Evaluation Of Colour Reproduction Of Cad/Cam Lithuim-Disilicate Veneers Of Different Thicknesses And Translucency, Sahar H. Fikry, Tarek Salah Morsi, Mennatallah M. Wahba, Amr El-Etreby Jun 2022

Evaluation Of Colour Reproduction Of Cad/Cam Lithuim-Disilicate Veneers Of Different Thicknesses And Translucency, Sahar H. Fikry, Tarek Salah Morsi, Mennatallah M. Wahba, Amr El-Etreby

Future Dental Journal

Background: With the increasing patients’ demand for a perfect smile, the call for highly aesthetic and yet minimally invasive veneers has surmounted. Objective: The aim of this study was to evaluate the colour of CAD/CAM lithium disilicate veneers fabricated in different thicknesses and different translucencies of the lithium disilicate blocks. Materials and Methods: Forty discs of lithium disilicate glass-ceramic (IPS e.max CAD) of shade A1 of both high and low translucency (HT, LT) were tested for their colour reproduction. HT and low LT blocks were cut in the form of plates of dimensions (12 x 14 mm) and of different …


Effect Of Abutments Design On Wear Of Locator Attachments In Implant Retained Mandibular Overdenture., Mahmoud Saleh Fayed, Medhat Sameh Abdelaziz, Hossam I. Nassar Jun 2022

Effect Of Abutments Design On Wear Of Locator Attachments In Implant Retained Mandibular Overdenture., Mahmoud Saleh Fayed, Medhat Sameh Abdelaziz, Hossam I. Nassar

Future Dental Journal

Purpose: The aim of this study is to compare the effect of abutments design on wear behavior of Locator attachments in implant-retained mandibular overdenture. Materials and Methods: Two epoxy models representing an edentulous mandible were used, two implants were placed in each model. Twenty-four locator attachments were used (twelve in each study group). Cycles of Insertion and removal were performed using a universal testing machine resembling 3 years of clinical use, then each abutment was scanned by scanning electron microscope (SEM) before and after insertion and removal cycles. Data were compared qualitatively using a specialized computer software Results: There was …


Effect Of Various Sintering Protocols On The Translucency Of Highly Translucent Cubic Zirconia, Kerolos Salah Mehany, Ashraf Hussein Sherif, Shereen Ahmed Nossair, Mona Hossam El-Din Mandour Jun 2022

Effect Of Various Sintering Protocols On The Translucency Of Highly Translucent Cubic Zirconia, Kerolos Salah Mehany, Ashraf Hussein Sherif, Shereen Ahmed Nossair, Mona Hossam El-Din Mandour

Future Dental Journal

Aim of the study: This study was carried out to evaluate the effect of various sintering protocols on the translucency of highly translucent cubic zirconia. Materials and methods: A total of forty discs of two types of zirconia ceramics were used in this study. The specimens were divided into two main groups according to the type of zirconia; Group 1 (n=20): Cubic zirconia (DD Cube X2 98color) and Group 2 (n=20): Tetragonal zirconia (BioZX2color). Each group was subdivided into two subgroups, where 10 discs were per subgroup according to the sintering protocol. Cubic and tetragonal zirconia blanks of dimensions (98 …


Management Of Post Covid 19 Mucormycosis With Osteomyelitis In The Maxilla, New Combined Consequences Of The Pandemic. (Case Report)., Hussein El Charkawi Proffesor, Omar A. El Sharkawy Jun 2022

Management Of Post Covid 19 Mucormycosis With Osteomyelitis In The Maxilla, New Combined Consequences Of The Pandemic. (Case Report)., Hussein El Charkawi Proffesor, Omar A. El Sharkawy

Future Dental Journal

ABSTRACT:

Aim: This case report aims to demonstrate among health providers the importance of timely surgical and prosthetic management procedures of patients who suffered from the newly combined clinical entity of post COVID 19 mucormycosis and osteomyelitis of the palate. Materials and methods: Elaborate advanced diagnosis of the patients including CBCT, MRI, CT, Pathology examination, 3Ds printing reconstruction of the whole skull and digital design of reconstructive mesh that support the prosthesis were carried out. The patients undergone modified infrastructure maxillectomy and immediate prosthetic obturation of the palatal defect that was replaced later by a delayed obturator. Results: Surgical eradication …


Comparison Between Two Different Attachment Caps Used In Locator Attachments Of Implant Supported Overdentures (In-Vitro Study), Hossam Eldein Faisal Haridy, Hebatalla Mahmoud El Afandy, Mohammed Farouk Abdalla, Ahmed Mohammed Osama Jun 2022

Comparison Between Two Different Attachment Caps Used In Locator Attachments Of Implant Supported Overdentures (In-Vitro Study), Hossam Eldein Faisal Haridy, Hebatalla Mahmoud El Afandy, Mohammed Farouk Abdalla, Ahmed Mohammed Osama

Future Dental Journal

Purpose: To compare different retentive cap material used in LOCATOR attachments, namely the nylon retentive cap versus PEEK retentive caps, and measure the loss of retention over a period of two years, through 2880 cycles of insertion and removal. Materials and methods: Two implants 3.8mm x 10.5mm were inserted into a clear epoxy resin cast, through a surgical guide, with the implants being 23mm apart. Two LOCATOR attachments with 5 mm gingival height were screwed to the implants, custom made nylon caps were fabricated as an exact replica of the PEEK retentive caps, then two dentures were constructed …


Retention Loss Of Locator Attachment System Different Retention Caps For Two Implant Retained Mandibular Overdenture., Medhat Sameh Abdelaziz, Aya Fawzy, Rami Maher Ghali, Hossam I. Nassar Mar 2022

Retention Loss Of Locator Attachment System Different Retention Caps For Two Implant Retained Mandibular Overdenture., Medhat Sameh Abdelaziz, Aya Fawzy, Rami Maher Ghali, Hossam I. Nassar

Future Dental Journal

Abstract

Purpose. The objective of this invitro study was to evaluate gradual loss of retention at different time intervals between four different colour coded retentive caps of locator R-TX attachment system through 3000 cycles resembling 3years of attachment usage.

Material and Methods. According to prosthetically driven implant placement, two implants were digitally planned and placed by 3D printed surgical stent in an epoxy model. Forty-eight mandibular complete dentures divided into four groups (12 dentures for each group) were constructed to compare Loss of retention between (12 pairs of locator R-TX each retention cap: zero retention, low retention, medium retention and …


Evaluation Of Strength Of Different Resin Materials Used In Overdenture, Mohamed Emam, Hesham E. Alam El Deen, Hamdy Abu El Fotoh, Ayman Fateen Mar 2022

Evaluation Of Strength Of Different Resin Materials Used In Overdenture, Mohamed Emam, Hesham E. Alam El Deen, Hamdy Abu El Fotoh, Ayman Fateen

Future Dental Journal

Introduction: Finding a suitable material that could be used to restore relatively small inter-arch spaces in which reasonable aesthetics as well as good functional strength could be achieved is a difficult process that requires good understanding of the clinical situation and precise management. Historically Metal used to offer the smallest possible thickness with excellent strength but lacks resiliency with poor aesthetics.

Aim of the study: This In-vitro study was conducted to compare two different aesthetic materials PEEK and ACETAL regarding their mechanical strength when used as Overdenture framework in a relatively small thickness.

Material and Methods: 120 specimens were …


Evaluation Of Incorporating Bracing Arm In Precision Attachment Unilateral Removable Partial Denture, Hussein El Charkawi, Aya Fawzy, Mohamed M. Dohiem Mar 2022

Evaluation Of Incorporating Bracing Arm In Precision Attachment Unilateral Removable Partial Denture, Hussein El Charkawi, Aya Fawzy, Mohamed M. Dohiem

Future Dental Journal

ABSTRACT

Purpose: This Randomized Control Trial study aimed to compare between two designs of Precision Attachment Unilateral Removable Partial Denture, one conventional design and the other modified with bracing arm and mesial rest.

Materials and Methods: twenty male patients having Kennedy Class II mandibular edentulous ridges received the two designs in a split mouth study for a follow-up period of eighteen months. Probing Pocket Depth around abutment was measured. A standardized radiographic technique was used to evaluate bone height changes.

Results: The results showed insignificant pocket depth and bone height changes in the two groups.

Conclusion: Precision Attachment Unilateral Removable …


The Effect Of Thickness And Accelerated Aging On Opalescence Of Different Ceramic Materials, Omar Hussein Abdelbary, Marwa Mohamed Wahsh, Ashraf Hussein Sherif, Tarek Salah Morsi Mar 2022

The Effect Of Thickness And Accelerated Aging On Opalescence Of Different Ceramic Materials, Omar Hussein Abdelbary, Marwa Mohamed Wahsh, Ashraf Hussein Sherif, Tarek Salah Morsi

Future Dental Journal

Purpose: The objective of the study was to evaluate the effect of ceramic material type and thickness on opalescence before and after accelerated aging. Materials and methods: 180 all-ceramic slices were divided into three groups (n=60) according to the ceramic material (InCoris TZI, Empress CAD HT, and Empress CAD LT). Each group was further subdivided into four subgroups (n = 15) according to their thickness (0.5 mm, 0.8 mm, 1 mm and 1.2 mm).). CIE Lab coordinates were measured for each slice against black and white backgrounds using intraoral spectrophotometer and OP was calculated. All specimens were subjected to …