Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Medicine and Health Sciences

Subspecialty Surveillance Of Long-Term Course Of Small And Moderate Muscular Ventricular Septal Defect: Heterogenous Practices, Low Yield., Erik L. Frandsen, Aswathy V. House, Yunbin Xiao, David A. Danford, Shelby Kutty Nov 2014

Subspecialty Surveillance Of Long-Term Course Of Small And Moderate Muscular Ventricular Septal Defect: Heterogenous Practices, Low Yield., Erik L. Frandsen, Aswathy V. House, Yunbin Xiao, David A. Danford, Shelby Kutty

Journal Articles: Pediatrics

BACKGROUND: No expert consensus guides practice for intensity of ongoing pediatric cardiology surveillance of hemodynamically insignificant small and moderate muscular ventricular septal defect (mVSD). Therefore, despite the well-established benign natural history of mVSD, there is potential for widely divergent follow up practices. The purpose of this investigation was to evaluate (1) variations in follow up of mVSD within an academic children's hospital based pediatric cardiology practice, and (2) the frequency of active medical or surgical management resulting from follow up of mVSD.

METHODS: We retrospectively reviewed records of 600 patients with isolated mVSD echocardiographically diagnosed between 2006 and 2012. Large …


Technical Performance Score Is Associated With Outcomes After The Norwood Procedure., Meena Nathan, Lynn A. Sleeper, Richard G. Ohye, Peter C. Frommelt, Christopher A. Caldarone, James S. Tweddell, Minmin Lu, Gail D. Pearson, J William Gaynor, Christian Pizarro, Ismee A. Williams, Steven D. Colan, Carolyn Dunbar-Masterson, Peter J. Gruber, Kevin Hill, Jennifer Hirsch-Romano, Jeffrey P. Jacobs, Jonathan R. Kaltman, S Ram Kumar, David Morales, Scott M. Bradley, Kirk Kanter, Jane W. Newburger, Pediatric Heart Network Investigators, Girish S. Shirali Nov 2014

Technical Performance Score Is Associated With Outcomes After The Norwood Procedure., Meena Nathan, Lynn A. Sleeper, Richard G. Ohye, Peter C. Frommelt, Christopher A. Caldarone, James S. Tweddell, Minmin Lu, Gail D. Pearson, J William Gaynor, Christian Pizarro, Ismee A. Williams, Steven D. Colan, Carolyn Dunbar-Masterson, Peter J. Gruber, Kevin Hill, Jennifer Hirsch-Romano, Jeffrey P. Jacobs, Jonathan R. Kaltman, S Ram Kumar, David Morales, Scott M. Bradley, Kirk Kanter, Jane W. Newburger, Pediatric Heart Network Investigators, Girish S. Shirali

Manuscripts, Articles, Book Chapters and Other Papers

Objectives: The technical performance score (TPS) has been reported in a single center study to predict the outcomes after congenital cardiac surgery. We sought to determine the association of the TPS with outcomes in patients undergoing the Norwood procedure in the Single Ventricle Reconstruction trial.

Methods: We calculated the TPS (class 1, optimal; class 2, adequate; class 3, inadequate) according to the predischarge echocardiograms analyzed in a core laboratory and unplanned reinterventions that occurred before discharge from the Norwood hospitalization. Multivariable regression examined the association of the TPS with interval to first extubation, Norwood length of stay, death or transplantation, …


Variability Of M-Mode Versus Two-Dimensional Echocardiography Measurements In Children With Dilated Cardiomyopathy., Caroline K. Lee, Renee Margossian, Lynn A. Sleeper, Charles E. Canter, Shan Chen, Lloyd Y. Tani, Girish S. Shirali, Anita Szwast, Elif Seda Selamet Tierney, M Jay Campbell, Fraser Golding, Yanli Wang, Karen Altmann, Steven D. Colan, Pediatric Heart Network Investigators Apr 2014

Variability Of M-Mode Versus Two-Dimensional Echocardiography Measurements In Children With Dilated Cardiomyopathy., Caroline K. Lee, Renee Margossian, Lynn A. Sleeper, Charles E. Canter, Shan Chen, Lloyd Y. Tani, Girish S. Shirali, Anita Szwast, Elif Seda Selamet Tierney, M Jay Campbell, Fraser Golding, Yanli Wang, Karen Altmann, Steven D. Colan, Pediatric Heart Network Investigators

Manuscripts, Articles, Book Chapters and Other Papers

M-mode and 2-dimensional (2D) echocardiographic imaging are routinely used to quantify left-ventricular (LV) size and function in pediatric patients with dilated cardiomyopathy (DCM). The reproducibility of and correlation between these techniques are unknown. This analysis sought to compare interreader, intrareader, and interacquisition reproducibility of M-mode versus 2D measurements in pediatric DCM patients. The Ventricular Volume Variability study of the Pediatric Heart Network is a multicenter, prospective, observational study assessing the course of chronic DCM in children. Two sonographers performed baseline image acquisitions locally, and two readers performed measurements at the echocardiographic core laboratory. One reader repeated measurements 1 month later. …


Prevention Of Arteriovenous Shunt Occlusion Using Microbubble And Ultrasound Mediated Thromboprophylaxis., Shelby Kutty, Juefei Wu, James M. Hammel, Joseph R. Abraham, Jeeva Venkataraman, Ibrahim Abdullah, David A. Danford, Stanley J. Radio, John Lof, Thomas R. Porter Feb 2014

Prevention Of Arteriovenous Shunt Occlusion Using Microbubble And Ultrasound Mediated Thromboprophylaxis., Shelby Kutty, Juefei Wu, James M. Hammel, Joseph R. Abraham, Jeeva Venkataraman, Ibrahim Abdullah, David A. Danford, Stanley J. Radio, John Lof, Thomas R. Porter

Journal Articles: Pediatrics

BACKGROUND: Palliative shunts in congenital heart disease patients are vulnerable to thrombotic occlusion. High mechanical index (MI) impulses from a modified diagnostic ultrasound (US) transducer during a systemic microbubble (MB) infusion have been used to dissolve intravascular thrombi without anticoagulation, and we sought to determine whether this technique could be used prophylactically to reduce thrombus burden and prevent occlusion of surgically placed extracardiac shunts.

METHODS AND RESULTS: Heparin-bonded ePTFE tubular vascular shunts of 4 mm×2.5 cm (Propaten; W.L Gore) were surgically placed in 18 pigs: a right-sided side-to-side arteriovenous (AV, carotid-jugular) shunt, and a left-sided arterio-arterial (AA, carotid-carotid) interposition shunt …