Targeting Accuracy Considerations For Simultaneous Tumor Treating Fields Antimitotic Therapy During Robotic Hypofractionated Radiation Therapy., Sharmi Biswas, Irina Kapitanova, Sabrina Divekar, Jimm Grimm, Ian J Butterwick, Daniel Garren, Lawrence R Kleinberg, Kristin J Redmond, Michel Lacroix, Anand Mahadevan, Kenneth M Forster Jan 2021

Targeting Accuracy Considerations For Simultaneous Tumor Treating Fields Antimitotic Therapy During Robotic Hypofractionated Radiation Therapy., Sharmi Biswas, Irina Kapitanova, Sabrina Divekar, Jimm Grimm, Ian J Butterwick, Daniel Garren, Lawrence R Kleinberg, Kristin J Redmond, Michel Lacroix, Anand Mahadevan, Kenneth M Forster

College of Health Professions Faculty Papers

Purpose: Tumor treating fields (TTFields) is a novel antimitotic treatment that was first proven effective for glioblastoma multiforme, now with trials for several extracranial indications underway. Several studies focused on concurrent TTFields therapy with radiation in the same time period, but were not given simultaneously. This study evaluates the targeting accuracy of simultaneous radiation therapy while TTFields arrays are in place and powered on, ensuring that radiation does not interfere with TTFields and TTFields does not interfere with radiation. This is one of several options to enable TTFields to begin several weeks sooner, and opens potential for synergistic effects of …


Quality Assurance Guidelines For Superficial Hyperthermia Clinical Trials : Ii. Technical Requirements For Heating Devices., Hana Dobšíček Trefná, Johannes Crezee, Manfred Schmidt, Dietmar Marder, Ulf Lamprecht, Michael Ehmann, Jacek Nadobny, Josefin Hartmann, Nicolleta Lomax, Sultan Abdel-Rahman, Sergio Curto, Akke Bakker, Mark D. Hurwitz, Chris J. Diederich, Paul R. Stauffer, Gerard C. Van Rhoon May 2017

Quality Assurance Guidelines For Superficial Hyperthermia Clinical Trials : Ii. Technical Requirements For Heating Devices., Hana Dobšíček Trefná, Johannes Crezee, Manfred Schmidt, Dietmar Marder, Ulf Lamprecht, Michael Ehmann, Jacek Nadobny, Josefin Hartmann, Nicolleta Lomax, Sultan Abdel-Rahman, Sergio Curto, Akke Bakker, Mark D. Hurwitz, Chris J. Diederich, Paul R. Stauffer, Gerard C. Van Rhoon

Department of Radiation Oncology Faculty Papers

Quality assurance (QA) guidelines are essential to provide uniform execution of clinical trials with uniform quality hyperthermia treatments. This document outlines the requirements for appropriate QA of all current superficial heating equipment including electromagnetic (radiative and capacitive), ultrasound, and infrared heating techniques. Detailed instructions are provided how to characterize and document the performance of these hyperthermia applicators in order to apply reproducible hyperthermia treatments of uniform high quality. Earlier documents used specific absorption rate (SAR) to define and characterize applicator performance. In these QA guidelines, temperature rise is the leading parameter for characterization of applicator performance. The intention of this …


Feasibility Of Improving Cone-Beam Ct Number Consistency Using A Scatter Correction Algorithm., Jun Li, Weiguang Yao, Ying Xiao, Yan Yu Nov 2013

Feasibility Of Improving Cone-Beam Ct Number Consistency Using A Scatter Correction Algorithm., Jun Li, Weiguang Yao, Ying Xiao, Yan Yu

Department of Medicine Faculty Papers

The study was to explore the feasibility of improving cone-beam CT (CBCT) number (corresponding to the Hounsfield units in computed tomography) consistency using a scatter-correction algorithm, with the aim of using CBCT images for treatment planning with density correction. A scatter correction algorithm was applied to a Varian OBI CBCT and an Elekta XVI CBCT, and was evaluated for improving CBCT number consistency. CBCT numbers of phantom materials were compared between images with and without bolus, which introduced additional scatter, and with and without scatter correction processing. It was observed that CBCT numbers were different in the images with and …


Quantitative, Spectrally-Resolved Intraoperative Fluorescence Imaging, Pablo A. Valdés, Frederic Leblond, Valerie L. Jacobs, Brian C. Wilson, Keith D. Paulsen, David W. Roberts Nov 2012

Quantitative, Spectrally-Resolved Intraoperative Fluorescence Imaging, Pablo A. Valdés, Frederic Leblond, Valerie L. Jacobs, Brian C. Wilson, Keith D. Paulsen, David W. Roberts

Dartmouth Scholarship

Intraoperative visual fluorescence imaging (vFI) has emerged as a promising aid to surgical guidance, but does not fully exploit the potential of the fluorescent agents that are currently available. Here, we introduce a quantitative fluorescence imaging (qFI) approach that converts spectrally-resolved data into images of absolute fluorophore concentration pixel-by-pixel across the surgical field of view (FOV). The resulting estimates are linear, accurate, and precise relative to true values, and spectral decomposition of multiple fluorophores is also achieved. Experiments with protoporphyrin IX in a glioma rodent model demonstrate in vivo quantitative and spectrally-resolved fluorescence imaging of infiltrating tumor margins for the …


The Effects Of Field-Of-View And Patient Size On Ct Numbers From Cone-Beam Computed Tomography., Katrina Y T Seet, Arvand Barghi, Slav Yartsev, Jacob Van Dyk Oct 2009

The Effects Of Field-Of-View And Patient Size On Ct Numbers From Cone-Beam Computed Tomography., Katrina Y T Seet, Arvand Barghi, Slav Yartsev, Jacob Van Dyk

Oncology Publications

Cone-beam computed tomography (CBCT) is used for patient alignment before treatment and is ideal for use in adaptive radiotherapy to account for tumor shrinkage, organ deformation and weight loss. However, CBCT images are prone to artifacts such as streaking and cupping effects, reducing image quality and CT number accuracy. Our goal was to determine the optimum combination of cone-beam imaging options to increase the accuracy of image CT numbers. Several phantoms with and without inserts of known relative electron densities were imaged using the Varian on-board imaging system. It was found that CT numbers are most influenced by the selection …


Consistency Check Of Planned Adaptive Option On Helical Tomotherapy., M Schirm, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk Dec 2008

Consistency Check Of Planned Adaptive Option On Helical Tomotherapy., M Schirm, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk

Oncology Publications

This study aims to evaluate a new Planned Adaptive software (TomoTherapy Inc., Madison, WI) of the helical tomotherapy system by retrospective verification and adaptive re-planning of radiation treatment. Four patients with different disease sites (brain, nasal cavity, lungs, prostate) were planned in duplicate using the diagnostic planning kVCT data set and MVCT studies of the first treatment fraction with the same optimization parameters for both plan types. The dosimetric characteristics of minimum, maximum, and mean dose to the targets as well as to organs at risk were compared. Both sets of plans were used for calculation of dose distributions in …


Quality Assurance Of Radiation Therapy Planning Systems: Current Status And Remaining Challenges., Jacob Van Dyk May 2008

Quality Assurance Of Radiation Therapy Planning Systems: Current Status And Remaining Challenges., Jacob Van Dyk

Oncology Publications

Computerized radiation therapy planning systems (RTPSs) are pivotal for treatment planning. The acceptance, commissioning, and quality control of RTPSs are uniquely complex and are described in the American Association of Physicists in Medicine Task Group Report 53 (1998) and International Atomic Energy Agency Technical Report Series No. 430 (2004). The International Atomic Energy Agency also developed a document and data package for use by vendors and purchasers to aid with acceptance testing of RTPSs. This document is based on International Electrotechnical Commission standard 62083 (2000) and describes both "type" tests to be performed in the factory and "site" tests to …