Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Oncology

Thomas Jefferson University

Series

2013

Feasibility Studies

Articles 1 - 2 of 2

Full-Text Articles in Medicine and Health Sciences

Targeting Cell Cycle And Hormone Receptor Pathways In Cancer., C E S Comstock, M A Augello, J F Goodwin, R De Leeuw, M J Schiewer, W F Ostrander, R A Burkhart, A K Mcclendon, Peter Mccue, Edouard J. Trabulsi, Costas D. Lallas, Leonard G Gomella, Md, M M Centenera, Jonathan Brody, Md, L M Butler, W D Tilley, K E Knudsen, Phd Nov 2013

Targeting Cell Cycle And Hormone Receptor Pathways In Cancer., C E S Comstock, M A Augello, J F Goodwin, R De Leeuw, M J Schiewer, W F Ostrander, R A Burkhart, A K Mcclendon, Peter Mccue, Edouard J. Trabulsi, Costas D. Lallas, Leonard G Gomella, Md, M M Centenera, Jonathan Brody, Md, L M Butler, W D Tilley, K E Knudsen, Phd

Department of Cancer Biology Faculty Papers

The cyclin/cyclin-dependent kinase (CDK)/retinoblastoma (RB)-axis is a critical modulator of cell cycle entry and is aberrant in many human cancers. New nodes of therapeutic intervention are needed that can delay or combat the onset of malignancies. The antitumor properties and mechanistic functions of PD-0332991 (PD; a potent and selective CDK4/6 inhibitor) were investigated using human prostate cancer (PCa) models and primary tumors. PD significantly impaired the capacity of PCa cells to proliferate by promoting a robust G1-arrest. Accordingly, key regulators of the G1-S cell cycle transition were modulated including G1 cyclins D, E and A. Subsequent investigation demonstrated the ability …


Feasibility Of Improving Cone-Beam Ct Number Consistency Using A Scatter Correction Algorithm., Jun Li, Weiguang Yao, Ying Xiao, Yan Yu Nov 2013

Feasibility Of Improving Cone-Beam Ct Number Consistency Using A Scatter Correction Algorithm., Jun Li, Weiguang Yao, Ying Xiao, Yan Yu

Department of Medicine Faculty Papers

The study was to explore the feasibility of improving cone-beam CT (CBCT) number (corresponding to the Hounsfield units in computed tomography) consistency using a scatter-correction algorithm, with the aim of using CBCT images for treatment planning with density correction. A scatter correction algorithm was applied to a Varian OBI CBCT and an Elekta XVI CBCT, and was evaluated for improving CBCT number consistency. CBCT numbers of phantom materials were compared between images with and without bolus, which introduced additional scatter, and with and without scatter correction processing. It was observed that CBCT numbers were different in the images with and …