Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Medicine and Health Sciences

Physicians' Experiences With Brca1/2 Testing In Community Settings., Nancy L. Keating, Kathryn A. Stoeckert, Meredith M. Regan, Lisa Digianni, Judy E. Garber Dec 2008

Physicians' Experiences With Brca1/2 Testing In Community Settings., Nancy L. Keating, Kathryn A. Stoeckert, Meredith M. Regan, Lisa Digianni, Judy E. Garber

Kathryn Sabella

PURPOSE: We surveyed a national sample of nonacademic physicians who ordered BRCA1/2 testing to understand their implementation of genetic testing and to assess recommendations for surveillance and cancer risk management of women with positive test results.

PATIENTS AND METHODS: We surveyed physicians (N = 611 of 1,050; response rate, 58.2%) practicing in nonacademic settings who ordered BRCA1/2 testing during 2004 to 2005. We described physicians' experiences with testing and used multivariable regression models to identify factors associated with more complete counseling and with recommendations for cancer risk management for a BRCA1 mutation carrier.

RESULTS: Most physicians (68.2%) usually or always …


Mira V: An Integrated System For Minimally Invasive Robot-Assisted Lung Brachytherapy, A. Trejos, A. Lin, S. Mohan, H. Bassan, C. Edirisinghe, R. Patel, C. Lewis, E. Yu, A. Fenster, R. Malthaner Apr 2008

Mira V: An Integrated System For Minimally Invasive Robot-Assisted Lung Brachytherapy, A. Trejos, A. Lin, S. Mohan, H. Bassan, C. Edirisinghe, R. Patel, C. Lewis, E. Yu, A. Fenster, R. Malthaner

Edward Yu

An integrated system for minimally invasive robot-assisted image-guided lung brachytherapy has been developed. The system incorporates an experimental setup for accurate radioactive seed placement with commercially available dosimetry planning software. The end result is a complete system that allows planning and executing a brachytherapy procedure with increased accuracy. The results of the in vitro seed placement evaluation show that seed misplacement has a significant effect on the volume receiving more than 200% of the dose (V200), and the minimum dosage received by 90% of the volume (D90).


Dosimetric Evaluation Of Helical Tomotherapy Treatment Planning For Non-Small Cell Lung Cancer, Karen Chu, George Rodrigues, Slav Yartsev, A. Rashid Dar, Edward Yu, Robert Ash, Brian Yaremko, Marc Mackenzie, Harvey Quon, Glenn Bauman, Wilson Roa Dec 2007

Dosimetric Evaluation Of Helical Tomotherapy Treatment Planning For Non-Small Cell Lung Cancer, Karen Chu, George Rodrigues, Slav Yartsev, A. Rashid Dar, Edward Yu, Robert Ash, Brian Yaremko, Marc Mackenzie, Harvey Quon, Glenn Bauman, Wilson Roa

Edward Yu

Helical tomotherapy (HT) is a novel technique to deliver intensity modulated radiation therapy guided by 3D megavoltage CT imaging. The purpose of our study is to assess the dosimetric parameters related to HT and 3DCRT in advanced non-small cell lung cancer (NSCLC). Eleven patients from the London Regional Cancer Centre and the Cross Cancer Institute with NSCLC underwent individualized treatment planning on both HT and 3DCRT. Corresponding HT and 3DCRT plans for each patient were analyzed using dose-volume histograms for GTV, PTV (median dose 60Gy/30 fractions), and critical structures (lung V5-30, esophageal V50-60, and spinal cord D1). Observed differences in …