Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Oncology

PDF

Dissertations & Theses (Open Access)

Theses/Dissertations

Phantom

Publication Year

Articles 1 - 3 of 3

Full-Text Articles in Medicine and Health Sciences

Design, Fabrication, And Validation Of 3d Printed, Patient-Specific Compensators For Postmastectomy Radiation Therapy, Daniel Craft Aug 2018

Design, Fabrication, And Validation Of 3d Printed, Patient-Specific Compensators For Postmastectomy Radiation Therapy, Daniel Craft

Dissertations & Theses (Open Access)

The purpose of this study was to use 3D printed, patient-specific tissue compensators to overcome the 3D planning limitations for postmastectomy radiation therapy (PMRT). Tissue compensators can be used to reduce dose heterogeneity, hot and cold spots at field junctions, and treatment complexity, but are currently seldom used due to the difficulty in designing, fabricating, and validating them.

To produce compensators using 3D printing technology, suitable materials had to be found and characterized. Several materials were found to be promising, but previously unreported material uncertainties were also discovered that must be carefully controlled for in 3D printing studies. A new …


The Development And Implementation Of An Anthropomorphic Head Phantom For The Assessment Of Proton Therapy Treatment Procedures, Paige A. Summers Aug 2011

The Development And Implementation Of An Anthropomorphic Head Phantom For The Assessment Of Proton Therapy Treatment Procedures, Paige A. Summers

Dissertations & Theses (Open Access)

Proton therapy has become an increasingly more common method of radiation therapy, with the dose sparing to distal tissue making it an appealing option, particularly for treatment of brain tumors. This study sought to develop a head phantom for the Radiological Physics Center (RPC), the first to be used for credentialing of institutions wishing to participate in clinical trials involving brain tumor treatment of proton therapy. It was hypothesized that a head phantom could be created for the evaluation of proton therapy treatment procedures (treatment simulation, planning, and delivery) to assure agreement between the measured dose and calculated dose within …


Benchmarking And Implementation Of A New Independent Monte Carlo Dose Calculation Quality Assurance Audit Tool For Clinical Trials, Scott E. Davidson Aug 2010

Benchmarking And Implementation Of A New Independent Monte Carlo Dose Calculation Quality Assurance Audit Tool For Clinical Trials, Scott E. Davidson

Dissertations & Theses (Open Access)

Introduction Commercial treatment planning systems employ a variety of dose calculation algorithms to plan and predict the dose distributions a patient receives during external beam radiation therapy. Traditionally, the Radiological Physics Center has relied on measurements to assure that institutions participating in the National Cancer Institute sponsored clinical trials administer radiation in doses that are clinically comparable to those of other participating institutions. To complement the effort of the RPC, an independent dose calculation tool needs to be developed that will enable a generic method to determine patient dose distributions in three dimensions and to perform retrospective analysis of radiation …