Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 11 of 11

Full-Text Articles in Medicine and Health Sciences

The Effects Of Field-Of-View And Patient Size On Ct Numbers From Cone-Beam Computed Tomography., Katrina Y T Seet, Arvand Barghi, Slav Yartsev, Jacob Van Dyk Oct 2009

The Effects Of Field-Of-View And Patient Size On Ct Numbers From Cone-Beam Computed Tomography., Katrina Y T Seet, Arvand Barghi, Slav Yartsev, Jacob Van Dyk

Oncology Publications

Cone-beam computed tomography (CBCT) is used for patient alignment before treatment and is ideal for use in adaptive radiotherapy to account for tumor shrinkage, organ deformation and weight loss. However, CBCT images are prone to artifacts such as streaking and cupping effects, reducing image quality and CT number accuracy. Our goal was to determine the optimum combination of cone-beam imaging options to increase the accuracy of image CT numbers. Several phantoms with and without inserts of known relative electron densities were imaged using the Varian on-board imaging system. It was found that CT numbers are most influenced by the selection …


Effects Of Genistein Following Fractionated Lung Irradiation In Mice., Andrea E Para, Andrea Bezjak, Ivan W T Yeung, Jacob Van Dyk, Richard P Hill Sep 2009

Effects Of Genistein Following Fractionated Lung Irradiation In Mice., Andrea E Para, Andrea Bezjak, Ivan W T Yeung, Jacob Van Dyk, Richard P Hill

Oncology Publications

BACKGROUND AND PURPOSE: This study investigated protection of lung injury by genistein following fractionated doses of radiation and its effect on tumor response.

MATERIAL AND METHODS: C3H/HeJ mice were irradiated (100 kVp X-rays) with 9 fractions of 3.1 Gy over 30 days (approximately equivalent to 10 Gy single dose) and were maintained on a genistein diet ( approximately 10mg/kg). Damage was assessed over 28 weeks in lung cells by a cytokinesis block micronucleus (MN) assay and by changes in breathing rate and histology. Tumor protection was assessed using a colony assay to determine cell survival following in situ irradiation of …


Pillows For Pain, Michael Lock Aug 2009

Pillows For Pain, Michael Lock

Michael Lock

No abstract provided.


A Fully Automated Non-External Marker 4d-Ct Sorting Algorithm Using A Serial Cine Scanning Protocol, Greg Carnes, Stewart Gaede, Edward Yu, Jake Van Dyk, Jerry Battista, Ting-Yim Lee Apr 2009

A Fully Automated Non-External Marker 4d-Ct Sorting Algorithm Using A Serial Cine Scanning Protocol, Greg Carnes, Stewart Gaede, Edward Yu, Jake Van Dyk, Jerry Battista, Ting-Yim Lee

Edward Yu

Current 4D-CT methods require external marker data to retrospectively sort image data and generate CT volumes. In this work we develop an automated 4D-CT sorting algorithm that performs without the aid of data collected from an external respiratory surrogate. The sorting algorithm requires an overlapping cine scan protocol. The overlapping protocol provides a spatial link between couch positions. Beginning with a starting scan position, images from the adjacent scan position (which spatial match the starting scan position) are selected by maximizing the normalized cross correlation (NCC) of the images at the overlapping slice position. The process was continued by 'daisy …


Y27632, A Rho-Activated Kinase Inhibitor, Normalizes Dysregulation In Alpha1-Adrenergic Receptor-Induced Contraction Of Lyon Hypertensive Rat Artery Smooth Muscle., Maria Regina Freitas, Masumi Eto, Jason A Kirkbride, Christa Schott, Jean Sassard, Jean-Claude Stoclet Mar 2009

Y27632, A Rho-Activated Kinase Inhibitor, Normalizes Dysregulation In Alpha1-Adrenergic Receptor-Induced Contraction Of Lyon Hypertensive Rat Artery Smooth Muscle., Maria Regina Freitas, Masumi Eto, Jason A Kirkbride, Christa Schott, Jean Sassard, Jean-Claude Stoclet

Department of Molecular Physiology and Biophysics Faculty Papers

RhoA-activated kinase (ROK) is involved in the disorders of smooth muscle contraction found in hypertension model animals and patients. We examined whether the alpha1-adrenergic receptor agonist-induced ROK signal is perturbed in resistance small mesentery artery (SMA) of Lyon genetically hypertensive (LH) rats, using a ROK antagonist, Y27632. Smooth muscle strips of SMA and aorta were isolated from LH and Lyon normotensive (LN) rats. After Ca(2+)-depletion and pre-treatment with phenylephrine (PE), smooth muscle contraction was induced by serial additions of CaCl(2). In LH SMA Ca(2+) permeated cells to a lesser extent as compared with LN SMA, while CaCl(2)-induced contraction of LH …


Analysis Of Carotid Lumen Surface Morphology Using Three-Dimensional Ultrasound Imaging, Bernard Chiu, Vadim Beletsky, J David Spence, Grace Parraga, Aaron Fenster Mar 2009

Analysis Of Carotid Lumen Surface Morphology Using Three-Dimensional Ultrasound Imaging, Bernard Chiu, Vadim Beletsky, J David Spence, Grace Parraga, Aaron Fenster

Medical Biophysics Publications

Carotid plaque surface irregularity and ulcerations play an important role in the risk of ischemic stroke. Ulcerated or fissured plaque, characterized by irregular surface morphology, exposes thrombogenic materials to the bloodstream, possibly leading to life- or brain-threatening thrombosis and embolization. Therefore, the quantification of plaque surface irregularity is important to identify high-risk plaques that would likely lead to vascular events. Although a number of studies have characterized plaque surface irregularity using subjective classification schemes with two or more categories, only a few have quantified surface irregularity using an objective and continuous quantity, such as Gaussian or mean curvature. In this …


Nonrigid Registration Of Three-Dimensional Ultrasound And Magnetic Resonance Images Of The Carotid Arteries, Nuwan D Nanayakkara, Bernard Chiu, Abbas Samani, J David Spence, Jagath Samarabandu, Grace Parraga, Aaron Fenster Feb 2009

Nonrigid Registration Of Three-Dimensional Ultrasound And Magnetic Resonance Images Of The Carotid Arteries, Nuwan D Nanayakkara, Bernard Chiu, Abbas Samani, J David Spence, Jagath Samarabandu, Grace Parraga, Aaron Fenster

Medical Biophysics Publications

Atherosclerosis at the carotid bifurcation can result in cerebral emboli, which in turn can block the blood supply to the brain causing ischemic strokes. Noninvasive imaging tools that better characterize arterial wall, and atherosclerotic plaque structure and composition may help to determine the factors which lead to the development of unstable lesions, and identify patients at risk of plaque disruption and stroke. Carotid magnetic resonance (MR) imaging allows for the characterization of carotid vessel wall and plaque composition, the characterization of normal and pathological arterial wall, the quantification of plaque size, and the detection of plaque integrity. On the other …


The Use Of Ct Density Changes At Internal Tissue Interfaces To Correlate Internal Organ Motion With An External Surrogate, Stewart Gaede, Gregory Carnes, Edward Yu, Jake Van Dyk, Jerry Battista, Ting-Yim Lee Jan 2009

The Use Of Ct Density Changes At Internal Tissue Interfaces To Correlate Internal Organ Motion With An External Surrogate, Stewart Gaede, Gregory Carnes, Edward Yu, Jake Van Dyk, Jerry Battista, Ting-Yim Lee

Edward Yu

The purpose of this paper is to describe a non-invasive method to monitor the motion of internal organs affected by respiration without using external markers or spirometry, to test the correlation with external markers, and to calculate any time shift between the datasets. Ten lung cancer patients were CT scanned with a GE LightSpeed Plus 4-Slice CT scanner operating in a ciné mode. We retrospectively reconstructed the raw CT data to obtain consecutive 0.5 s reconstructions at 0.1 s intervals to increase image sampling. We defined regions of interest containing tissue interfaces, including tumour/lung interfaces that move due to breathing …


Adaptive Radiation Therapy For Localized Mesothelioma With Mediastinal Metastasis Using Helical Tomotherapy., James Renaud, Slav Yartsev, A Rashid Dar, Jacob Van Dyk Jan 2009

Adaptive Radiation Therapy For Localized Mesothelioma With Mediastinal Metastasis Using Helical Tomotherapy., James Renaud, Slav Yartsev, A Rashid Dar, Jacob Van Dyk

Oncology Publications

The purpose of this study was to compare 2 adaptive radiotherapy strategies with helical tomotherapy. A patient having mesothelioma with mediastinal nodes was treated using helical tomotherapy with pretreatment megavoltage CT (MVCT) imaging. Gross tumor volumes (GTVs) were outlined on every MVCT study. Two alternatives for adapting the treatment were investigated: (1) keeping the prescribed dose to the targets while reducing the dose to the OARs and (2) escalating the target dose while maintaining the original level of healthy tissue sparing. Intensity modulated radiotherapy (step-and-shoot IMRT) and 3D conformal radiotherapy (3DCRT) plans for the patient were generated and compared. The …


Post-Operative Extended Volume External Beam Radiation Therapy In High Risk Esophageal Cancer Patients: A Prospective Experience, E. Yu, P. Tai, J. Younus, R. Malthaner, P. Truong, L. Stitt, G. Rodrigues, R. Ash, R. Dar, B. Yaremko, A. Tomiak, B. Dingle, M. Sanatani, M. Vincent, W. Kocha, D. Fortin, R. Inculet Dec 2008

Post-Operative Extended Volume External Beam Radiation Therapy In High Risk Esophageal Cancer Patients: A Prospective Experience, E. Yu, P. Tai, J. Younus, R. Malthaner, P. Truong, L. Stitt, G. Rodrigues, R. Ash, R. Dar, B. Yaremko, A. Tomiak, B. Dingle, M. Sanatani, M. Vincent, W. Kocha, D. Fortin, R. Inculet

Edward Yu

Background and purpose: Extended volume external beam radiation therapy (RT) following esophagectomy is controversial. This prospective study evaluates the feasibility of extended volume RT treatment in high-risk esophagectomy patients with cervical anastomosis receiving post–operative combined chemo-radiation therapy. Patients and methods: From 2001-2006, 15 patients with resected esophageal cancer were prospectively accrued to this pilot study, to evaluate the adverse effects of extended volume RT. Eligibility criteria were pathologically proven esophageal malignancy, T3-4, N0-1, disease amenable to surgical resection and esophagectomy with or without resection margin involvement. Patients with distant metastases (M1) and patients treated with previous RT were excluded. All …


Alamethicin In Lipid Bilayers: Combined Use Of X-Ray Scattering And Md Simulations, Jianjun Pan, D. Peter Tieleman, John F. Nagle, Norbert Kučerka, Prof. Stephanie Tristram-Nagle Ph.D. Dec 2008

Alamethicin In Lipid Bilayers: Combined Use Of X-Ray Scattering And Md Simulations, Jianjun Pan, D. Peter Tieleman, John F. Nagle, Norbert Kučerka, Prof. Stephanie Tristram-Nagle Ph.D.

Prof. Stephanie Tristram-Nagle Ph.D.

We study fully hydrated bilayers of two di-monounsaturated phospholipids diC18:1PC (DOPC) and diC22:1PC with varying amounts of alamethicin (Alm). We combine the use of X-ray diffuse scattering and molecular dynamics simulations to determine the orientation of alamethicin in model lipids. Comparison of the experimental and simulated form factors shows that Alm helices are inserted transmembrane at high humidity and high concentrations, in agreement with earlier results. The X-ray scattering data and the MD simulations agree that membrane thickness changes very little up to 1/10 Alm/ DOPC. In contrast, the X-ray data indicate that the thicker diC22:1PC membrane thins with added …