Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Dentistry

PDF

Ove Peters

2017

Cone-Beam Computed Tomography

Articles 1 - 2 of 2

Full-Text Articles in Medicine and Health Sciences

Interrelationships In The Variability Of Root Canal Anatomy Among The Permanent Teeth: A Full-Mouth Approach By Cone-Beam Ct., Paul Monsarrat, Bertrand Arcaute, Ove A. Peters, Elisabeth Maury, Norbert Telmon, Marie Georgelin-Gurgel, Delphine Maret Oct 2017

Interrelationships In The Variability Of Root Canal Anatomy Among The Permanent Teeth: A Full-Mouth Approach By Cone-Beam Ct., Paul Monsarrat, Bertrand Arcaute, Ove A. Peters, Elisabeth Maury, Norbert Telmon, Marie Georgelin-Gurgel, Delphine Maret

Ove Peters

OBJECTIVES: In endodontic practice, clinicians should be aware of possible root canal anatomic variations. The aim of this study was to assess using CBCT acquisitions regarding whether one root canal anatomy of a tooth is associated with a specific anatomy of another tooth. METHODS: A total of 106 CBCT acquisitions were obtained using a CBCT scanner with 200μm voxel size. Numbers of roots and canals of the entire dentition were described. Bivariate analyses and logistic regressions were conducted to explore root canal anatomy on one tooth according to age, gender, jaw, side and the others teeth. Multiple correspondence analysis (MCA) …


Effect Of Voxel Size On The Accuracy Of 3d Reconstructions With Cone Beam Ct., Delphine Maret, Norbert Telmon, Ove A. Peters, B. Lepage, J. Treil, J. M. Inglèse, A. Peyre, Jean-Luc Kahn, Michel Sixou Oct 2017

Effect Of Voxel Size On The Accuracy Of 3d Reconstructions With Cone Beam Ct., Delphine Maret, Norbert Telmon, Ove A. Peters, B. Lepage, J. Treil, J. M. Inglèse, A. Peyre, Jean-Luc Kahn, Michel Sixou

Ove Peters

OBJECTIVES: The various types of cone beam CT (CBCT) differ in several technical characteristics, notably their spatial resolution, which is defined by the acquisition voxel size. However, data are still lacking on the effects of voxel size on the metric accuracy of three-dimensional (3D) reconstructions. This study was designed to assess the effect of isotropic voxel size on the 3D reconstruction accuracy and reproducibility of CBCT data. METHODS: The study sample comprised 70 teeth (from the Institut d'Anatomie Normale, Strasbourg, France). The teeth were scanned with a KODAK 9500 3D® CBCT (Carestream Health, Inc., Marne-la-Vallée, France), which has two voxel …